Laserfiche WebLink
Napco Commercial" Platform GEMC System Components: <br /> 24V Fire, Burglary or Combination Burg./Fire Systems <br /> SYSTEM Napco Commercial Platform Systems <br /> Simultaneously support all-new UL <br /> •Main Control board supports up to(2)Addressable SLCs(Signaling commercial Firewolf fire and Gemini <br /> Line Circuit controllers). burglary devices in hardwire,wireless <br /> •Fire Addressable SLC Loop Controller and addressable technologies <br /> pi—_ <br /> •Burg Addressable SLC Loop Controller <br /> •Fire 4-wire bus for keypads and conventional devices Napco Commercial Platform Advantages <br /> •Burglary Control Module <br /> •Provides Isolated Burg 4-wire bus for keypads and conventional •Easy Wire Compatibility-SLC controller supports shielded,unshielded, <br /> devices twisted and untwisted wire-ideal for retrofits <br /> •Provides independent Burg battery connection and charger •Longer SLC loop lengths,support more device load each,too <br /> •Provides 12V power (see below for distance at maximum device load in alarm/standby <br /> •Independent Burg Bell output each) <br /> •Power Supply includes either 4A or 7A @ 24V • 10,000ft.#14AWG•6,200ft#16AWG•4,000 ft.#18AWG <br /> •Integrates with NAPCO ACM–Access Control Modules •Support for Legacy and Existing Notification Appliances-One NAC <br /> •RS-232 Printer Module for optional onsite parallel printer output configurable for 12V for easy retrofit compatibility <br /> •Supports a maximum of 15 Keypads,mounted anywhere on the bus, •UL Regulated NAC outputs <br /> fire GEMC-FK1 or burg.GEMC-BK1.(7 fire keypads,max.Or,as few as 1 •Automatic drift compensation for system's analog smoke detectors <br /> fire keypad required on fire system or equipment savings.) •Separate 7A NAC Extender–(4)NAC's,may be installed anywhere on <br /> •Addressable SLC Loop Isolator(optional use-for some fire the 4-wire bus.Provides universal FACP support. <br /> applications requiring increased circuit integrity) •Keypads mount anywhere on the bus and have flash-able firmware– <br /> •Dual Phone Line built in for updates via Quickloader <br /> •2 Onboard Serial Ports-One for internet reporting;One for high- •Smoke Obsuration Report-Quickloader device sensitivity report <br /> speed local downloading allows the printout of a report for the AHJ listing the current status of <br /> •TCP/IP Internet reporting module all analog smoke detectors in the system including the programmed <br /> •Regulated Auxiliary Power Supplies-Commercial Burglary or fire, 12V obscuration level for each device and the actual sensitivity reading for <br /> regulated 2A or 1.75A version with plug in transfomer each device.Report is generated in 3 ways-either remotely(uploaded) <br /> •Choice of two panel enclosures -Between the studs enclosure,recess or locally through notebook PC or use optional onsite printer. <br /> or surface mount.Larger version,with reversible door,supports up •Isolated backup battery circuits for Burglary and Fire for EZ backup <br /> to 32Ah at 24V.Dimensions:24"x 14.25"x 5.2"(H x W x D)without calculation and AHJ compliance;allows dealer to accommodate <br /> cover. Removable battery shelves,accomodate pairs of 7Ah,7.5Ah separate backup times for burg and fire.This allows burg system to <br /> and 8Ah batts.etc.Smaller Enclosure–supports 16Ah at 24V. drop out after burg battery depletion,while fire system is maintained <br /> Dimensions: 16"x 14.25"x 5.2"(H x W x D)without cover.(16Ah and extremely stable for extended period. <br /> battery backup capacity). •Full line of UL Commercial Devices for more flexibility&labor-savings <br /> Example,Use Gemini Commercial Wireless 2-input module(GEMC- <br /> INPUTS WL-WD2)to convert any UL listed device into a UL wireless device, <br /> Up to 255 Zones.Points/Zones can come from any of the following ideal for sprinkler supervisories or for use with pull stations(mounts <br /> initiating devices(in up to 8 partitionable areas): on top of wall/conduit or in deep sngle-gang box(plastic). <br /> •Addressable SLC Loop(Burg or Fire)–supports up to(2)126 point Firewolf Fire-Only 24V Intelligent Addressable Fire Configuration, <br /> loops NFPA72 <br /> •Commercial RF Receiver– •Main Control board-supports(1)Addressable Fire SLC controller <br /> •Supports Commercial Wireless Fire devices •Fire 4-wire bus for keypads and conventional devices <br /> •Wireless Smoke Detector •Power Supply 7A and 4A <br /> •Wireless Heat Detector •RS-232 Printer Module <br /> •Supports Commercial Wireless Burglary devices •Fire Keypad with Gemini-style Menu-functionality <br /> •Wireless PIR Sensor •Dual Phone Line built in;Synch module built in(System Sensor& <br /> •Wireless Dual Technology Sensor Wheelock protocols) <br /> •Wireless Glass break Sensor Firewoff 32-Point Conventional Kit for Sprinkler/Waterflow <br /> •Wireless 2-Point Window/Door Transmitter <br /> •Conventional 1-to 4-zone EZM Expansion modules on the 4-wire burg (See ordering info.) <br /> or fire bus or SLC loops NAC Extender-Powerful flexibility <br /> •Conventional 2-wire or 4-wire smoke detector input module •Nearly 7Amps power <br /> •Addressable SLC Fire Devices Supported: •4 onboard NACs with up to 2A ea.,expandable for up to 24 per <br /> •Analog Smoke Detector system <br /> •Heat Detector •Up to 16Ah total battery capacity <br /> •Duct Detector •Regulated 24V Aux.power <br /> •Pull Station •Distributes synched bell and strobe outputs with built-in module <br /> •Conventional Zone Module •Monitors AC,battery trouble,tamper and ground fault on Napco bus <br /> •Short Circuit Isolator -or-provides universal FACP support. <br /> •Addressable SLC Burg Devices Supported: Gemini-C Burglary-Only Configuration,Commercial Conventional/ <br /> • 1 Zone Burg Input Module Addressable 96-Zone System <br /> •4 Zone Burg Input modules •Supports full line of new GEMC Commercial-rated addressable, <br /> •PIR Motion Sensor conventional or wireless devices simultaneously <br /> •Dual Tech Microwave/PIR Sensor •8 to 96 fully-configurable zones,with up to 7 partitions <br /> OUTPUTS •Familiar Napco Quickloader up/downloading and keypad operation <br /> Up to 96 outputs •Dual line DACT on board <br /> •Four on board Class B or 2 Class A NAC circuits,2 amps each,total 6.5 Compliances <br /> amps at 24V NFPA 72,UL Commercial Fire,UL864 9th Ed.,SIA CP01,UL985.UL <br /> •Built in Wheelock and System Sensor NAC sync/strobe/horn protocol household&commercial burg.:UL1610,UL609,UL365,UL1023.NYC FD; <br /> allows initial silence of audible appliances while maintaining visual CSFM(fire). <br /> notification,without the use of additional modules. <br /> •Addressable SLC Fire Devices:Supervised relay,unsupervised relay ��/� –C� �� <br /> •Addressable SLC Burg Devices:unsupervised relay C� <br /> •Burg/Fire 4-wire bus devices:8 zone form C relay(GEMC-RM3008),8 <br /> open collector output(GEMC-OUTS) <br /> Wd lti <br />