2012-00697 - fire alarm system
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
2725 Wayzata Boulevard West - 33-118-23-13-0019
>
Permits/Inspections
>
2012-00697 - fire alarm system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:47:35 PM
Creation date
2/3/2020 10:34:53 AM
Metadata
Fields
Template:
x Address Old
House Number
2725
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
2725 Wayzata Boulevard West
Document Type
Permits/Inspections
PIN
3311823130019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/7 GEMC-FW-SLC <br /> NFIRE SIGNALING LINE CIRCUIT MODULE <br /> PCO <br /> 333 Bayview Avenue DATA SHEET <br /> Amityville,New York 11701 <br /> For Sales and Repairs,(800)645-9445 <br /> For Technical Service,(800)645-9440 <br /> Publicly tmded on NASDAQ Symbol:NSSc ©NAPCO 2010 WI1889 09/10 <br /> DESCRIPTION <br /> The GEMC-FW-SLC Signaling Line Circuit Module is the PHYSICAL <br /> hardwired interface between compatible NAPCO Fire Dimensions W x D x H: 4.5"x 4"x 1" <br /> SLC devices and the Gemini C-Series control panels. <br /> The 2-Wire UL Commercial Fire Listed SLC system re- AGENCY LISTINGS <br /> quires a Gemini C-Series control panel and at least one <br /> of the below listed compatible SLC Fire devices in order UL864 9th Edition: Commercial Fire <br /> to operate. These devices may be smoke detectors, UL985: Household Fire Warning System Units <br /> heat detectors, NAC devices, single or dual Fire- NFPA 72 National Fire Alarm Code <br /> initiating circuit-input devices, or other compatible de- Security Industry Association (SIA) False Alarm Reduc- <br /> vices that report zone status and supervision information tion Standard CP-01 <br /> to the GEMC-FW-SLC. CSFM: California State Fire Marshall (Pending) <br /> THE GEMC-FW-SLC module supports up to 126 Fire FM Approval: (Pending) <br /> SLC devices. A maximum of two GEMC-FW-SLC mod- NYCFD: NYC Fire Department(Pending) <br /> ules may be used with any Gemini C-Series control <br /> panel for a maximum total of 252 Fire SLC zones. The ORDERING INFORMATION <br /> GEMC-FW-SLC module is mounted inside the control GEMC-FW-SLC: Addressable SLC Fire Module, sup- <br /> panel metal housing and is connected to the control ports up to 128 addressable SLC Fire devices. Con- <br /> panel motherboard via the supplied connector. The nects to the GEMC control panel (2 maximum). <br /> GEMC-FW-SLC module polls each device, continually <br /> monitoring and updating the Fire status and conveying <br /> this information to the control panel. If there is no re- <br /> sponse from a Fire SLC device, a trouble will occur <br /> within 200 seconds. <br /> IMPORTANT: Only the NAPCO Firewolf SLC devices <br /> are compatible with the Gemini C-Series system. These <br /> NAPCO Fire SLC devices may NOT be used on other <br /> systems due to incompatibilities with this proprie- <br /> tary communication protocol. <br /> VERY IMPORTANT: For ANY keypad programming, <br /> the SLC board MUST be enabled in PCD-Windows <br /> Quickloader by opening the System Assignment <br /> screen, RF-Receiver/SLC tab. <br /> SPECIFICATIONS, GEMC-FW-SLC MODULE <br /> Electrical Ratings <br /> Input Power: <br /> Power Requirements: 24VDC, 70mA(standby current) <br /> + device current. <br /> Maximum Total Combined 24V Input Current: <br /> 475mA. <br /> Output Power: 36V pk, 150mA maximum. The addi- <br /> tional alarm current (5 LED's @ 8mA for 40mA) is auto- <br /> matically added to determine standby+ alarm current. <br /> Note: Refer to PCD-Windows Quickloader download <br /> software's calculation tools for 24V standby current cal- <br /> culation. GEMC-Series total combined 24V auxiliary <br /> standby current must be reduced by GEMC-FW-SLC <br /> input current. <br /> Maximum Line Impedance: 5012 <br /> 7 7,�5 Way zal <br /> vim✓ t v <br />