My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Re: engineering review
Orono
>
Property Files
>
Street Address
>
T
>
Turnham Road
>
125 Turnham Road - 31-118-23-43-0018
>
Correspondence
>
Re: engineering review
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:33:00 PM
Creation date
7/1/2019 1:37:56 PM
Metadata
Fields
Template:
x Address Old
House Number
125
Street Name
Turnham
Street Type
Road
Address
125 Turnham Road
Document Type
Correspondence
PIN
3111823430018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
View images
View plain text
• = BO ETON M B N K , I NC® <br /> Consulting Engineers & Surveyors <br /> 2638 Shadow Lane, Suite 200•Chaska, MN 55318-1172 <br /> Phone(952)448-8838• Fax(952)448-8805 <br /> www.bolton-menk.com <br /> July 16,2012 <br /> City of Orono <br /> Attn: Melanie Curtis <br /> PO Box 66 <br /> Orono,Mn 55323 <br /> RE: Building Permit Application 2012-00589 <br /> House Construction <br /> 125 Turnham Road <br /> Dear Melanie: <br /> As requested,we have completed an engineering review of the documents submitted for the above <br /> referenced project. Our current review is based on the documents listed below,and we offer the <br /> following observations,comments,and recommendations for your consideration. <br /> Submittal Documents <br /> • Building Permit Application dated June 25,2012 <br /> • Certificate of Survey prepared by Gronberg&Associates dated June 14,2012 <br /> • Resolution 6117 approving CUP <br /> • Wetland Buffer Establishment Plan <br /> • MCWD correspondence regarding Erosion Control and Wetland Protection permits <br /> Review Comments <br /> 1. Per City Council resolution 6117,the following items should be conditional to the approval of the <br /> building permit: <br /> a. The City Engineer shall be allowed to inspect any fill being brought to the site prior to it <br /> being placed. <br /> b. The applicant shall work with the City Engineer to locate and install protection around <br /> the potential septic areas to insure they are not impacted and compacted during fill <br /> activities. The protection fencing location must be inspected and approved by the City <br /> Engineer prior to any land disturbing activities other than placement of silt fence. <br /> c. The applicant shall confirm with the City Engineer acceptable hours of truck hauling and <br /> provide documentation on the haul route to be used. Acceptable hours and haul route <br /> must be approved prior to the importing of any fill. <br /> d. If fill is imported to the site,the City Engineer shall inspect roadways on haul route prior <br /> to and following completion of work to determine whether adverse impacts have <br /> occurred. The applicant shall be responsible for the repair to roadways for any adverse <br /> impacts. <br /> e. The cmp culvert under the driveway is in poor condition,with holes rusted through the <br /> top of the pipe. The culvert should be replaced as part of this project,matching existing <br /> size and elevations. <br /> f. The condition of the driveway and Turnham Road has been documented with digital <br /> pictures. A few minor ruts and riffles have been noted on the shared gravel driveway. <br />
The URL can be used to link to this page
Your browser does not support the video tag.
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).