Laserfiche WebLink
REVIEW PLAN <br />This plan is at a review stage and is NOT a permit set. Please review <br />the plan in its entirety and let DFP know if you have any changes prior <br />to us proceeding. The plan will be placed on hold until we receive <br />confirmation from you to proceed, meaning no additional work will be <br />done on the plan until we receive your approval to move forward. <br />�o <br />m <br />03/06/2018 1:09:28 PM <br />96'-6" <br />1_ 12'-6" 331-6" 501-6" 1 <br />121-6" <br />41'-0" <br />M <br />32'-0" <br />rn 0 <br />�o <br />�o <br />Ln z Ln <br />Lo cD o <br />(n00 <br />z w <br />0 <br />a -co <br />-w� <br />wo <br />z @ r� <br />Z i <br />Jw <br />C_3 m z <br />X <br />a <br />(DJ w <br />O Q <br />w w <br />� w <br />�N <br />0t w75 <br />w z o <br />v� <br />z o <br />� (D o <br />w E' co <br />Zoo <br />_Owm <br />Z o �; <br />a Qm <br />LL <br />J o <br />O m 0 <br />Ci amw� <br />5EE ENG (NEER IN6 PAGES 51-5X <br />F I R 5T FLOOR PLAN <br />56ALE : 1/4"4-011 <br />I'-0" <br />EXTERIOR 12IMEN51ONS ARE 5HEATHIN6 TO 5HEATHIN6 <br />FIRST FLOOR FINISHED 1,634 50. FT. <br />GARAGE 815 50. FT. <br />3 5EA50N PORCH 350 50. FT. <br />WINDOW & DOOR NOTE5 Z 0.i 4 <br />•XXX <br />•• CODE MIN. U VALUE = 0.32 MIN. 5TH6 = 0.35 W H 0 <br />• ALL WINDOWS SET 8'-0" UNLESS NOTED OTHERWISE A Z W <br />• BUILDER TO PROVIDE WINDOW ORDER L15T WITH U FACTOR, 1--1 <br />56HC, & 5TC RATING FOR EACH WINDOW & EXTERIOR DOOR a Z <br />• BUILDER TO VERIFY ALL WINDOW, DOOR & OPENING HDR. HTS. W Z <br />• FP = PROVIDE FALL PROTECTION @ OPERATING WINDOWS �y 0 <br />GUARDRAIL NOTE5 <br />• GUARDRAIL REQUIRED ON OPEN 51DE OF ANY STAIR MORE THAN <br />30" ABOVE FLOOR U) 0 <br />� Z <br />• ALL OPENIN65 LE55 THAN 4" AT ALL 6UARDRAIL5 w 0 <br />FLOOR 5Y5TEM NOTE5 <br />• ALL FLOORS TO BE L/480 Z <br />• FLOOR TRU55 MANUFACTURER TO VERIFY FRAMING BELOWr , <br />GRANITE TOPS, TUBS & TILE AREAS ABOVE 1+1 <br />• FLOOR TRUSS MANUFACTURER TO PROVIDE HEAT SUPPLY & <br />RETURN CHASE IN TRU55E5 <br />• BUILDER TO PROVIDE CITY WITH TRUSS LAYOUT PLANS <br />U <br />FRAM IN6 NOTE5 <br />• 9'-1 8" PLATE HEIGHT UNLE55 NOTED OTHF-RW15E <br />• 2X6 5TUD5 @ POCKET DOOR WALLS UNLE55 NOTED OTHERWISE <br />• DOUBLE 5TUD5 AT ALL WINDOW & PATIO DOOR HEADERS <br />UNLE55 NOTED OTHF-RW15F <br />• PROVIDE LVL/L5L 5OL ID BLOCKING AT ALL POINT LOAD5, <br />SUPPORT BEAMS, MICROLAM5, AND GIRDER TRUSSES TO <br />FOUN12AT ION <br />• PROVIDE FIREBLOCKING VERTICALLY @ GEILIN65 & FLOORS & <br />HORIZONTALLY @ INTERVALS NOT EXCEEDING 10'-0" <br />(CONGEALED SPACES @ SOFFITS, DROPPED GEILING5, BETWEEN <br />STAIR 5TRIN6ER5 & BETWEEN STORIES <br />• PROVIDE DRAFT STOPPING BETWEEN 5TORIE5 DIVIDED INTO <br />APPROXIMATELY EQUAL SPACES NOT EXCEEDING 1,000 SOFT. <br />• ALL SPRAY FOAM INSULATION MUST BE COVERED BY MIN." <br />GYP. BD AT HABITABLE AREAS <br />DATE: <br />3-6-I8 <br />REVISIONS: <br />BENCH I <br />W. I.C. <br />DRAWN BY: <br />KH <br />SMOKE <br />• <br />• <br />AND CAR60N MONOXIDE DETECTORS <br />PROVIDE SMOKE DETEGTOR5 IN EVERY BEDROOM & THE <br />CORRIDOR 61VIN6 AGGE55 TO THE BEDROOM ON EACH FLOOR <br />INCLUDING THE BASEMENT, & IN AY ROOM THAT HAS A CEILING <br />HEIGHT MORE THAN 24" HIGHER THAN A CORR I12OR G IV ING <br />AGGE55 TO THE BEDROOMS. <br />PROVIDE CARBON MONOXIDE DETECTOR5 WITHIN 10'-0" OF ALL <br />BEDROOM5 <br />COMM. NO. <br />217338 <br />SHEET NO. <br />3 <br />G.TILE <br />_ <br />28 <br />I <br />I <br />I <br />24 <br />I <br />I <br />I <br />o <br />I <br />I <br />o, <br />O W <br />9'-1 I /8" <br />2 <br />N GE IL. HT. <br />N MUD <br />C.T ILE <br />_ <br />1�J❑❑ <br />i <br />------------ <br />m <br />IIII <br />�i� <br />_ o <br />1 <br />----------- <br />-----------IIIIz <br />REF <br />N <br />l <br />II BUTLERS <br />I I PANTRY <br />24 <br />-, <br />T„ <br />III <br />I I G.TILE <br />112 <br />W. I.P. <br />W <br />III <br />II <br />.0. <br />0-3" <br />WALL HT. <br />_ G.TILE <br />r i-i---------------� r---------------------------------- <br />19 XS GARAGE DOOR I 116'X8' GARAGE DOOR <br />5'-0" <br />4'-6" <br />I <br />RECESS OPEN - <br />_ ± <br />j 4 <br />W/ 6LA55 W/ 6LA55 <br />24" FLOOR <br />TOWEL <br />TOWEL 5TOR. 1 <br />GAB. ABV. <br />III 2 <br />III <br />❑F �0 <br />81-1 1/81, <br />CE IL. HT. <br />I I I I <br />I I I I <br />I I I I <br />D IN IN6 <br />TRU55E5 <br />TOILET <br />1 <br />WOOD <br />19.2" O.G <br />� <br />= I <br />I a 1 <br />I I I I <br />0 0 <br />11� <br />I I I I <br />I <br />I <br />� u <br />9'-1 I /8 <br />� <br />13ATH <br />I I I I <br />-----------T- ____ <br />GEIL. HT. <br />K ITCHEN <br />1 <br />G.TILE <br />= <br />I I 151MP50N STH014 <br />I I I I <br />IF <br />I I <br />42" <br />G.T. <br />I I I ANCHOR STRAPS I <br />=� <br />I I <br />WOOD_ <br />10" TREAD5 <br />"' <br />I I I TH15 WALL 1 <br />L1 <br />✓ <br />42" <br />------------------ --------------------------------- <br />6QXSQ I <br />Q -Q <br />16 X8 <br />V <br />I I�' <br />I� <br />41 <br />i 3 5EA50N i DOOR <br />- <br />�—P!N <br />o <br />N <br />i PORCH i - - - - - - - - - - - <br />- - - - - - - - - - <br />- - - - - <br />- - - - - - - -I <br />M <br />UP ISR <br />17R <br />30 <br />III <br />PORCH <br />9'-I I/8" <br />GEIL. HT. <br />Ir----------TT--------------TT----------- <br />I I I I I I I I <br />IIII <br />FOYER <br />II II <br />II <br />I <br />IIII <br />WOOD <br />I I I <br />I I <br />I I <br />I <br />I <br />I <br />III 20- <br />I I I I <br />I - L <br />----------------- II II <br />I I <br />II <br />I <br />I <br />IIII <br />o <br />- <br />I I I <br />I <br />I! <br />2X6 <br />n <br />II II <br />II <br />I0 <br />SP.D. <br />-11�N <br />I <br />I <br />I <br />I I I I <br />I <br />STEP CEILING <br />I I <br />I <br />I <br />I <br />o <br />N <br />I <br />9'-9 1/8" GEIL. HT. <br />I <br />I <br />II II <br />GREAT ROOM <br />II <br />I <br />24 FLOOR <br />I <br />-WOOD <br />I <br />I <br />x <br />TRU55E5 <br />I <br />I <br />I <br />N <br />19.2" 0.0 <br />OFFICE <br />I <br />I <br />I <br />W. I.C. <br />I <br />" <br />14 FLOOR <br />I <br />I <br />-WOOD= <br />I I I I <br />I <br />TRU55E5 <br />I I <br />I <br />I <br />I <br />wooD <br />2p <br />I <br />I I I I <br />19.2" <br />I I <br />I <br />IL ----------- L I <br />-------------- <br />1----------- <br />L------ <br />-------------- <br />--------- <br />FLUSH HEARTH <br />____ <br />rT <br />D.V. GAS <br />_- FIREPLACE -- <br />121-6" <br />41'-0" <br />M <br />32'-0" <br />rn 0 <br />�o <br />�o <br />Ln z Ln <br />Lo cD o <br />(n00 <br />z w <br />0 <br />a -co <br />-w� <br />wo <br />z @ r� <br />Z i <br />Jw <br />C_3 m z <br />X <br />a <br />(DJ w <br />O Q <br />w w <br />� w <br />�N <br />0t w75 <br />w z o <br />v� <br />z o <br />� (D o <br />w E' co <br />Zoo <br />_Owm <br />Z o �; <br />a Qm <br />LL <br />J o <br />O m 0 <br />Ci amw� <br />5EE ENG (NEER IN6 PAGES 51-5X <br />F I R 5T FLOOR PLAN <br />56ALE : 1/4"4-011 <br />I'-0" <br />EXTERIOR 12IMEN51ONS ARE 5HEATHIN6 TO 5HEATHIN6 <br />FIRST FLOOR FINISHED 1,634 50. FT. <br />GARAGE 815 50. FT. <br />3 5EA50N PORCH 350 50. FT. <br />WINDOW & DOOR NOTE5 Z 0.i 4 <br />•XXX <br />•• CODE MIN. U VALUE = 0.32 MIN. 5TH6 = 0.35 W H 0 <br />• ALL WINDOWS SET 8'-0" UNLESS NOTED OTHERWISE A Z W <br />• BUILDER TO PROVIDE WINDOW ORDER L15T WITH U FACTOR, 1--1 <br />56HC, & 5TC RATING FOR EACH WINDOW & EXTERIOR DOOR a Z <br />• BUILDER TO VERIFY ALL WINDOW, DOOR & OPENING HDR. HTS. W Z <br />• FP = PROVIDE FALL PROTECTION @ OPERATING WINDOWS �y 0 <br />GUARDRAIL NOTE5 <br />• GUARDRAIL REQUIRED ON OPEN 51DE OF ANY STAIR MORE THAN <br />30" ABOVE FLOOR U) 0 <br />� Z <br />• ALL OPENIN65 LE55 THAN 4" AT ALL 6UARDRAIL5 w 0 <br />FLOOR 5Y5TEM NOTE5 <br />• ALL FLOORS TO BE L/480 Z <br />• FLOOR TRU55 MANUFACTURER TO VERIFY FRAMING BELOWr , <br />GRANITE TOPS, TUBS & TILE AREAS ABOVE 1+1 <br />• FLOOR TRUSS MANUFACTURER TO PROVIDE HEAT SUPPLY & <br />RETURN CHASE IN TRU55E5 <br />• BUILDER TO PROVIDE CITY WITH TRUSS LAYOUT PLANS <br />U <br />FRAM IN6 NOTE5 <br />• 9'-1 8" PLATE HEIGHT UNLE55 NOTED OTHF-RW15E <br />• 2X6 5TUD5 @ POCKET DOOR WALLS UNLE55 NOTED OTHERWISE <br />• DOUBLE 5TUD5 AT ALL WINDOW & PATIO DOOR HEADERS <br />UNLE55 NOTED OTHF-RW15F <br />• PROVIDE LVL/L5L 5OL ID BLOCKING AT ALL POINT LOAD5, <br />SUPPORT BEAMS, MICROLAM5, AND GIRDER TRUSSES TO <br />FOUN12AT ION <br />• PROVIDE FIREBLOCKING VERTICALLY @ GEILIN65 & FLOORS & <br />HORIZONTALLY @ INTERVALS NOT EXCEEDING 10'-0" <br />(CONGEALED SPACES @ SOFFITS, DROPPED GEILING5, BETWEEN <br />STAIR 5TRIN6ER5 & BETWEEN STORIES <br />• PROVIDE DRAFT STOPPING BETWEEN 5TORIE5 DIVIDED INTO <br />APPROXIMATELY EQUAL SPACES NOT EXCEEDING 1,000 SOFT. <br />• ALL SPRAY FOAM INSULATION MUST BE COVERED BY MIN." <br />GYP. BD AT HABITABLE AREAS <br />DATE: <br />3-6-I8 <br />REVISIONS: <br />DRAWN BY: <br />KH <br />SMOKE <br />• <br />• <br />AND CAR60N MONOXIDE DETECTORS <br />PROVIDE SMOKE DETEGTOR5 IN EVERY BEDROOM & THE <br />CORRIDOR 61VIN6 AGGE55 TO THE BEDROOM ON EACH FLOOR <br />INCLUDING THE BASEMENT, & IN AY ROOM THAT HAS A CEILING <br />HEIGHT MORE THAN 24" HIGHER THAN A CORR I12OR G IV ING <br />AGGE55 TO THE BEDROOMS. <br />PROVIDE CARBON MONOXIDE DETECTOR5 WITHIN 10'-0" OF ALL <br />BEDROOM5 <br />COMM. NO. <br />217338 <br />SHEET NO. <br />3 <br />