Laserfiche WebLink
REVIEW PLAN <br />This plan is at a review stage and is NOT a permit set. Please review <br />the plan in its entirety and let DFP know if you have any changes prior <br />to us proceeding. The plan will be placed on hold until we receive <br />confirmation from you to proceed, meaning no additional work will be <br />done on the plan until we receive your approval to move forward. <br />03/06/2018 1:09:28 PM <br />F- <br />87'-0" <br />f%L-VVLIL- FiJ nL-IAV. <br />FOR LAKE SET BACK <br />GOND IT ION5? <br />rn 7�; <br />'Q -O <br />Ito <br />Lo zLn <br />�00 <br />(nCO <br />z w <br />0 <br />a -CO <br />-w� <br />wo <br />z p <br />Z _j <br />w <br />C_3 m z <br />X <br />a <br />J w <br />O Q <br />w w <br />�w <br />�N <br />U <br />• GUARDRAIL REQUIRED ON OPEN SIDE OF ANY STAIR MORE THAN <br />30" ABOVE FLOOR <br />• ALL OPF-NIN65 LF -55 THAN 4" AT ALL GUARDRAILS <br />FRAM IN6 NOTE5 <br />• 8'-1 a" PLATE HEIGHT UNLE55 NOTED OTHERWI5E <br />• 2X6 STUDS @ POCKET DOOR WALLS UNLESS NOTED OTHERW15E <br />• DOUBLE STUDS AT ALL WINDOW & PATIO DOOR HEADER5 <br />UNLE55 NOTED OTHERW15F <br />• PROVIDE LVL/L5L SOLID BLOCK IN6 AT ALL POINT LOADS, <br />SUPPORT BEAMS, MI6ROLAM5, AND GIRDER TRU55E5 TO <br />FOUN12AT ION <br />• PROVIDE FIREBLOGK INC VERTICALLY @ GE IL ING5 & FLOORS & <br />HORIZONTALLY @ INTERVALS NOT EXCEEDING 10'-0" <br />(CONGEALED SPACES @ SOFFITS, DROPPED CEILINGS, BETWEEN <br />STAIR STRIN6ER5 & BETWEEN STORIES <br />• PROVIDE DRAFT 5TOPPIN6 BETWEEN STORIES DIVIDED INTO <br />APPROXIMATELY EQUAL SPACES NOT EXGEEDIN6 1,000 50.FT. <br />• ALL SPRAY FOAM INSULATION MUST BE COVERED BY MIN." <br />GYP. BD AT HABITABLE AREAS <br />W . <br />3-6-18 <br />REVISIONS: <br />5ECONn FLOOR PLAN <br />W H Co <br />SCALE 1/4"=I' -O" <br />co <br />EXTERIOR DIMEN510N5 ARE 5HEATHIN6 TO SHEATHING <br />A Z <br />SECOND FLOOR FINISHED 1,371 50. FT. <br />a Z <br />BONUS ROOM FINI5HED 653 50. FT. <br />rT, <br />WINDOW & DOOR NOTE5 <br />• XXXX WINDOW5 <br />., <br />•• CODE MIN. U VALUE = 0.32 MIN. STHC = 0.35 <br />Q <br />• ALL WINDOWS SET 0-10" UNLESS NOTED OTHERWISE <br />u Z <br />• BUILDER TO PROVIDE WINDOW ORDER L15T WITH U FACTOR, <br />M••1 <br />w <br />56HC, & 5TC RATING FOR EACH WINDOW & EXTERIOR DOOR <br />• BUILDER TO VERIFY ALL WINDOW, DOOR & OPENING HDR. HTS. <br />O� <br />• FP = PROVIDE FALL PROTECTION @ OPERATING WINDOWS <br />W CQ <br />GUARDRAIL NOTE5 <br />• GUARDRAIL REQUIRED ON OPEN SIDE OF ANY STAIR MORE THAN <br />30" ABOVE FLOOR <br />• ALL OPF-NIN65 LF -55 THAN 4" AT ALL GUARDRAILS <br />FRAM IN6 NOTE5 <br />• 8'-1 a" PLATE HEIGHT UNLE55 NOTED OTHERWI5E <br />• 2X6 STUDS @ POCKET DOOR WALLS UNLESS NOTED OTHERW15E <br />• DOUBLE STUDS AT ALL WINDOW & PATIO DOOR HEADER5 <br />UNLE55 NOTED OTHERW15F <br />• PROVIDE LVL/L5L SOLID BLOCK IN6 AT ALL POINT LOADS, <br />SUPPORT BEAMS, MI6ROLAM5, AND GIRDER TRU55E5 TO <br />FOUN12AT ION <br />• PROVIDE FIREBLOGK INC VERTICALLY @ GE IL ING5 & FLOORS & <br />HORIZONTALLY @ INTERVALS NOT EXCEEDING 10'-0" <br />(CONGEALED SPACES @ SOFFITS, DROPPED CEILINGS, BETWEEN <br />STAIR STRIN6ER5 & BETWEEN STORIES <br />• PROVIDE DRAFT 5TOPPIN6 BETWEEN STORIES DIVIDED INTO <br />APPROXIMATELY EQUAL SPACES NOT EXGEEDIN6 1,000 50.FT. <br />• ALL SPRAY FOAM INSULATION MUST BE COVERED BY MIN." <br />GYP. BD AT HABITABLE AREAS <br />DATE: <br />3-6-18 <br />REVISIONS: <br />DRAWN BY: <br />KH <br />5MOKE AND CARBON MONOXIDE PETECTOR5 <br />• PROVIDE SMOKE DETECTOR5 IN EVERY BEDROOM & THE <br />CORRIDOR 61VIN6 AGGE55 TO THE BEDROOM ON EACH FLOOR <br />IN6LUDIN6 THE BASEMENT, & IN AY ROOM THAT HAS A CEILING <br />HE ICHT MORE THAN 24 HIGHER THAN A CORRIDOR 61V INC <br />AGGE55 TO THE BEDROOMS. <br />• PROVIDE CARBON MONOXIDE DETECTORS WITHIN 10'-0" OF ALL <br />BEDROOM5 <br />COMM. NO. <br />217338 <br />SHEET NO. <br />4 <br />