Laserfiche WebLink
REVIEW PLAN <br />This plan is at a review stage and is NOT a permit set. Please review <br />the plan in its entirety and let DFP know if you have any changes prior <br />to us proceeding. The plan will be placed on hold until we receive <br />confirmation from you to proceed, meaning no additional work will be <br />done on the plan until we receive your approval to move forward. <br />03/06/2018 1:09:28 PM <br />SEE EN6INEERIN6 PAGES 51 -SX <br />FOUNDATION PLAN <br />SCALE; 1/4"=I' -O" <br />EXTERIOR DIMENSION ARE FROM EXTERIOR OF FOUNDATION WALLS <br />AT FULL BASEMENT AREAS AND A5 NOTED AT FRAMED WALLS AT <br />LOOKOUT AND WALKOUT AREAS <br />BASEMENT FINISHED XXXX 50. FT. <br />BASEMENT UNFIN151-1E0 XXXX 50. FT. <br />WINDOW & DOOR NOTES <br />• XXXX WINDOWS <br />CODE MIN. U VALUE = 0.32 MIN. 5THC = 0.35 <br />• •• ALL WINDOW5 SET AT 81-0" UNLE55 NOTED OTHERWISE <br />• BUILDER TO PROVIDE WINDOW ORDER L15T WITH U FACTOR, <br />5614C, & 5TC RATING FOR EACH WINDOW & EXTERIOR DOOR <br />• BUILDER TO VERIFY ALL WINDOW, DOOR & OPENING HDR. HT5. <br />• WINDOW WELLS WITH A VERTICAL DEPTH OF MORE THAN 44" <br />MUST BE EQUIPPED WITH AN APPROVED LADDER <br />GUARDRAIL NOTE5 <br />• GUARDRAIL REQUIRED ON OPEN SIDE OF ANY STAIR MORE THAN <br />30" ABOVE FLOOR <br />• ALL OPENINGS LE55 THAN 4" AT ALL GUARDRAILS <br />FLOOR 515TEM NOTE5 <br />• ALL FLOORS TO BE L/480 <br />• FLOOR TRU55 MANUFACTURER TO VERIFY FRAMING BELOW <br />GRANITE TOPS, TU135 & TILE AREAS ABOVE <br />• FLOOR TRU55 MANUFACTURER TO PROVIDE HEAT SUPPLY & <br />RETURN CHASE IN TRUSSES <br />• BUILDER TO PROVIDE CITY WITH TRU55 LAYOUT PLANS <br />FOUNDATION WALL & FOUNDATION INSULATION NOTE5 <br />• 91-0" POURED FOUNDATION WALLS W/ SINGLE PLATE <br />• BASEMENT FLOOR RAISED TO TOP OF WALKOUT STEM WALL <br />• A55UMED 501L BEARING CAPACITY 2,000 LBS <br />• MAINTAIN 42" MIN. GRADE ABOVE FOOTING <br />• BOTTOM OF DECK & PORCH FOOTIN65 TO BE 72" BELOW GRADE <br />• MA50NRY CONTRACTOR TO VERIFY WALL & FOOTING <br />REQUIREMENTS WITH 51TE CONDITION5 <br />• MA50NRY CONTRACTOR TO VERIFY ALL WALL AND FOOTING <br />REQUIREMENTS AT ALL UNBALANCED BACKFILL LOCATIONS <br />FX <br />SEE FOUNDATION WALL DETAIL ON PAGE DI <br />N X INDICATES DISTANCE FOUNDATION 15 HELD <br />IN FROM 5HEATHIN6 ABOVE <br />• FOUNDATION WALLS HELD IN FROM SHEATHING ABOVE A5 <br />INDICATED BY FOUNDATION WALL DETAIL <br />• SILL PLATE OVERHANGS FOUNDATION I #" MAXIMUM SEE <br />FOUNDATION WALL DETAIL5 (WHEN TRTD 2X8 PLATE 15 U5ED) <br />• <br />SEE FOUNDATION WALL DETAIL5 FOR FOUNDATION WALL <br />INSULATION (R-10 EXTERIOR/ R-5 INTERIOR) <br />5HEETROCK & IN511JLAT ION NOTE5 <br />• GYP. BD. REQUIRED AT ENTIRE CEILING (EXCEPT 80 50.FT. <br />MAXIMUM AT MECHANICAL) <br />• V GYP. BD. AT WALLS & CEILING BELOW STAIRS <br />• ALL SPRAY FOAM INSULATION MUST BE COVERED BY MIN. " <br />GYP. BD. AT HABITABLE AREAS <br />FRAMING NOTES <br />• 8'-9 1/2'' PLATE HEIGHT UNLE55 NOTED OTHERW15E <br />• 2X6 5TUD5 @ POCKET DOOR WALLS UNLE55 NOTED OTHERW15E <br />• DOUBLE 5TUD5 AT ALL WINDOW & PATIO DOOR HEADERS <br />UNLE55 NOTED OTHERW15F <br />• PROVIDE LVL/L5L SOLID BLOCKING AT ALL POINT LOAD5, <br />SUPPORT BEAMS, MICROLAM5, & GIRDER TRUSSES TO <br />FOUNDATION <br />• PROVIDE FIRE BLOCKING VERTICALLY @ CEILIN65 & FLOORS & <br />HORIZONTALLY @ INTERVALS NOT EXCEEDING 10'-0" <br />(CONCEALED 5PACE5 @ SOFFITS, DROPPED CEILINGS, BETWEEN <br />STAIR STRINGERS & BETWEEN STORIES) <br />• PROVIDE DRAFT STOPPING BETWEEN STORIES DIVIDED INTO <br />APPROXIMATELY EQUAL SPACES NOT EXCEEDING 1.000 SOFT. <br />SMOKE AND CAR60N MONOXIDE DETECTORS <br />• PROVIDE SMOKE DETECTOR5 IN EVERY BEDROOM & THE <br />CORRIDOR 61VIN6 ACCE55 TO THE BEDROOM ON EACH FLOOR <br />INCLUDING THE BASEMENT, & IN AY ROOM THAT HAS A CEILING <br />HEIGHT MORE THAN 24" HIGHER THAN A CORRIDOR GIVING <br />ACCESS TO THE BEDROOMS. <br />• PROVIDE CARBON MONOXIDE DETECTOR5 WITHIN 10'-0" OF ALL <br />BEDROOM5 <br />rn 7�; <br />'Q -O <br />Ito <br />Lo zLn <br />�00 <br />(nCO <br />z w <br />0 <br />a -CO <br />-w� <br />wo <br />z p <br />Z _j <br />w <br />C_3 m z <br />X <br />a <br />J w <br />O Q <br />w w <br />�w <br />�N <br />W <br />w E-4 O <br />q z co <br />0-4 Pq <br />Z <br />Jaz <br />i�+••I C <br />guz <br />C\2 <br />w <br />DATE: <br />3-6-18 <br />REVISIONS: <br />DRAWN BY: <br />KH <br />COMM. NO. <br />217338 <br />SHEET NO. <br />2 <br />U <br />