BACK BACK 7.SIDE WALL SIDING CUT LIST: . <br /> ]04 waferboard&T1-11:Cut 1-4'x8'into 2-4'x4'. <br /> 166 ifaferboard:Cut 2-4'x8'into 2-4'x6'. <br /> 2'x6' 4'x6' 4'x6' 10x6 T1-11:Cut 2-4'x8'into 2-4'x4'&2-2'x4'. <br /> 2'x8' 4'x8' 4'x8' 10x8 waferboard:No cutting required. Use 2-4'x8'. <br /> 10x8 T1-11:Cut 2-41x8'into 4-4'x4'. <br /> 10x10 waferboard:Cut 1-2'x8'into 2-2'x4'& use 2-4'x8'. <br /> 101x8' FRONT 10x10 T1-11:Cut 3-4'x8'into 4-4'x4'&2-2'x4'. <br /> BACK 10x12 waferboard:Cut 1-4'x8'into 2-4'x4'& use 2-4'x8'. <br /> 2'x2' 2W* 1 0x1 2 T1-11:Cut 3-4'x8'into 6-4'x4'. <br /> 2'x8' 4'x8' 4'x8' 10x14 waferboard:Cut 2-4'x8'into 2-4'x6'&use 2-4'x8'. <br /> 1 0x1 4 Ti-11:Cut 4-4'x8'into 6-4'x4'&2-2'x4'. <br /> 10x16 waferboard:No cutting required.Use 4-4'x8'. <br /> 2'x8' 4'x8' 4'x8' 10x16 T1-11:Cut 4-4'x8'into 8-4'x4'. <br /> 10'x14' FRONT <br /> j BACK <br /> 8. Set the prefabricated back wall into <br /> 101x1o' FRONTplace. The 2x6 on the bottom of the <br /> BACK 2'x8' 4'x8' 4'x8' Q back wall sits on the ends of the <br /> 3 TREATED RUNNERS(C).The middle <br /> 2'x4' 4'x8' x of the back wall must be tight against <br /> a the FLOOR SHEATHING.Nail the back <br /> m wall to the 2x6 FLOOR STRINGER A <br /> C ( ) <br /> with 3-16d nails on each side.Nail the <br /> C FLOOR SHEATHING to the back wall <br /> 2'x8' 4'x8' 4'x8' 2'x8' 4'x8' 4'x8' every 8". <br /> 10'x17 FRONT 101x18' FRONT <br /> 1 "S <br /> A <br /> 5.Chalk a line on the 2x6 FLilOR STRINGERS(A),2"from the <br /> bottom of the FLOOR STRINGER(A).Tack a 6d nail aboutevery <br /> 12"on the chalk line with the head of the nail sticking out about A <br /> 1".This tine will be used as a guide for the bottom edge of the side <br /> wall siding. <br /> 9A.T1-11 siding:Nail a 4'x4'piece on each side,with the overlapping <br /> edge of the siding even with the outside of the 2x3 on the back wall, <br /> with the bottom of the sheet on the nails on the chalk line on the 2x6 <br /> D FLOOR STRINGER(A).Nail only to the 2x3 on the back wall every 6" <br /> with 6d nails. <br /> D E 9B.Waferboard siding:Nail a 4'x8'(4'x4'on the 1 Ox4 barn&4'x6'on <br /> the 10x6 barn).on each side with the bottom of the sheet on the nails <br /> D D on the chalk line on the FLOOR STRINGER(A) and the edge even <br /> E with the outside of the 2x3 on the back wall.Nail only to the 2x3 on the <br /> back wall with 6d nails every 6". <br /> 6.Nail the JOIST HANGERS(D)with 4-6d nails,centered over 10.SIDE WALL& ROOF STRINGER CUT LIST: <br /> the"V"on the 2x3's on the front and back walls,and even with the 10'x4'-Cut 4-2x4x92 5/8"to 7-2x4x44 3/4". <br /> top of the 2x3's.Starting at the peak, measure down 22",place 10'x6'-Cut 7-2x4x92 5/8"to 5'8 3/4". <br /> this mark on each 2x3 on the back and front walls. Center the 10'x8'-Use 7-2x4x92 5/8. <br /> JOIST HANGER (E) on this mark. With the tips of the JOIST 10'x10'- Cut 7-2x4x10'to 9'8 3/4". <br /> HANGER(E) even with the TOP edge of the 2x3's,nail with 10'x12'- Cut 4-2x4x12'to 11'8 3/4"&3-2x6x12'to 11'8 3/4" (D). <br /> 4-6d nails.Bend over the nails that attach the trim boards on the 10'x14'-Cut 4-2x4x14'to 13'8 3/4"&3-2x6x14'to 13'8 3/4" (D). <br /> front wall and the door. 10'x16'-Cut 4-2x4x16'to 15'8 3/4"&3-2x6x16'to 15'8 3/4"(D). <br />