2018-00234 - alarm system
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0795 Old Crystal Bay Road North - 28-118-23-34-0003
>
Permits/Inspections
>
2018-00234 - alarm system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:24:41 PM
Creation date
1/18/2019 3:50:20 PM
Metadata
Fields
Template:
x Address Old
House Number
795
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
795 Old Crystal Bay Road North
Document Type
Permits/Inspections
PIN
2811823340003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
192
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Name: Plan Review and Inspection Checklist <br /> NFPA 13(2010 Edition) Page 4 of 5 <br /> Plan Inspection <br /> System Component Section Review Comments <br /> Yes No Yes No <br /> Sprinklers <br /> 1 Make,type, model, K-factor, and sprinkler 22,1.3(12) <br /> identification number indicated? <br /> 2 Are sprinklers listed for their use? 6.1.1 <br /> 3 Are nonmetallic escutcheons listed type? 6.2.7.1 <br /> Are escutcheons for recessed or flush sprinklers part <br /> 4 of listed assembly? 6'2.7'2 <br /> 5 Residential sprinklers used in residential areas? 8.4.5.1 /~ <br /> Are residential sprinklers within each compartment of <br /> 6 the same fast response type? 8.4.5.3 <br /> 7 Is the correct K-factor used? Table 6.2.3.1 <br /> Are small orifice sprinklers used on dry systems? 8.3.4.1(2) <br /> 8 Exception <br /> (Note exception) <br /> 8.6.4.1.4.4 <br /> Has strainer been provided for small orifice <br /> 9 8.3.4.1(3) <br /> sprinklers? <br /> 10 Do sprinklers have correct temperature rating? 8.3.2.1 <br /> 11 Have spare sprinklers and wrench been provided? 6.2.9 <br /> 12 List of sprinklers posted? 6.2.9.7 <br /> 13 Are guards provided for sprinklers subject to injury? 6.2.8 <br /> 14 Are all sprinkler coverage areas within listing limits? 8.1.1(2) <br /> 15 Are upright and pendent sprinklers correctly spaced 8.6.3.2&8.6.3.3 <br /> from walls? <br /> 16 Are sprinklers 4"minimum from walls? 8.7.3.3.1 & <br /> 8.6.33 <br /> Is minimum 18"clearance provided from sprinkler to " <br /> 17 top of storage? 8.5.6.1 \/1 <br /> 18 Are sprinklers within allowable distance below ceiling/ 8.5.4 <br /> roof? <br /> 19 Are combustible concealed spaces protected? 8.15.1 - • <br /> 20 Sprinklers located correctly under peaked roof? 8.6.4.1.3 <br /> 21 Are shafts protected with sprinklers? 8.15.2 <br /> 22 Sprinklers located to minimize obstructions? 8.5.5 <br /> 23 Skylights properly protected? 8.5.7 .� <br /> 24 Ceiling pockets properly protected? 8.6.7&8.8.7 <br /> NFPA 82(04)5.2.6 <br /> 25 Are chutes and discharge rooms protected? &5.2.7&MSFC <br /> 903.2.10.2 <br /> 26 Are floors, atriums and stair(vertical)openings 8.15.4 <br /> protected? <br /> 27 Are exterior balconies, decks, canopies and platforms 8 15.7 <br /> protected? <br /> Are sprinkler omissions from bathrooms in 8.15.8.1 - <br /> 28 accordance with correct size and construction NOTE: <br /> requirements? 8.15.8.1.2 <br /> Are sprinkler omissions from closets in accordance <br /> 29 with correct size and construction requirements? 8.15.8.2 • <br /> MSFC amendment <br /> 30 Are areas under OVHD doors, large ducts, etc. 8.5.5.3.1 <br /> protected? <br /> 31 Is commercial-type cooking equipment protected? 7.10&MSFC <br /> 904.2.1 <br /> 32 IAre coolers and freezers protected? (above&below) 4.1 &8.15.2.2.1 f IALie.-c v- cAry 5e-c.c1 15 <br />