My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-00234 - alarm system
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0795 Old Crystal Bay Road North - 28-118-23-34-0003
>
Permits/Inspections
>
2018-00234 - alarm system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:24:41 PM
Creation date
1/18/2019 3:50:20 PM
Metadata
Fields
Template:
x Address Old
House Number
795
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
795 Old Crystal Bay Road North
Document Type
Permits/Inspections
PIN
2811823340003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
192
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Name: Plan Review and Inspection Checklist <br /> NFPA 13(2010 Edition) Page 3 of 5 <br /> Plan Inspection <br /> System Component Section Review Comments <br /> Yes No ; Yes No <br /> _ Fire Department Connection <br /> 1 Has FDC been provided? 8.17.2.1 ✓ <br /> 2 Is FDC location acceptable? MSFC 903.3.7 v- <br /> 3 Is FDC 18"-48"above grade? MSFC 912.2.3 <br /> 4 Is FDC correct size? 8.17.2.3 <br /> 5 Is FDC correctly arranged within system? 8.17.2.4 ✓ <br /> 6 Check valve installed on FDC? (Verify direction) 8.17.2.5.1 � <br /> • <br /> 7 FDC check within 25 feet of FDC inlet? MSFC <br /> 903.3.1.6.4 %./' <br /> 8 Has sign stating system type been installed? 8.17.2.4.7 <br /> 9 Is there a shutoff valve between FDC and the Not allowed <br /> system? (8.17.2.5.2) /170' <br /> 10 Does FDC have proper threads? 6.8.1 <br /> 11 Does FDC have protective caps? 6.8.2 <br /> 12 Is the FDC accessible and unobstructed? 8.18.2.4.6 s <br /> 13 Ball drip properly installed? 8.17.2.6 <br /> Drains <br /> 1 Are there provisions to drain the riser? 8.16.2.4.2 /p-f- Alum <br /> 2 Are drains provided for each sectional control valve? 8.16.2.4.3 <br /> 3 Are auxiliary drains provided for isolated piping? 8.16.2.5 A6r4 g hi UPI <br /> 4 Do drains terminate at approved locations? 8.16.2.4.4 / <br /> 5 Common drain riser size increased? 8.16.2.4.7 Y /l/1/17(/t/it /"/ <br /> Piping and Fittings 4r f )vi/Z <br /> i <br /> 1 'Is piping approved type c. listed? I 6.3.1 I 11 I T <br /> 2 Do pipe bending techniques comply? 6.3.7 <br /> 3 Does cross main have provision for flushing? 8.16.3.2 I . <br /> 4 Is end of cross main a minimum size of 1-1/4"? 8.16.3.3 <br /> 5 Are return bends properly provided? 8.15.18 <br /> 6 Is piping protected from freezing? 8.16.4.1 <br /> 7 Is pipe protected against corrosion? 8.16.4.2 <br /> 8 Are pipe joining techniques proper? 6.5 <br /> 9 Are fittings approved type or listed? 6.4 <br /> 10 Gaskets listed for use on dry pipe system? 6.5.3.3 <br /> 11 Have fasteners been welded topiping? Not allowed <br /> 6.5.2.4.6(7) <br /> 12 Are screwed unions used on pipe over 2"? Not allowed <br /> • <br /> 6.4.5.1 <br /> 13 Has plastic pipe been installed in unapproved Per manufacturer <br /> exposed areas? _ <br /> 14 Is piping properly pitched? 8.16.2.1 <br />