2018-00234 - alarm system
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0795 Old Crystal Bay Road North - 28-118-23-34-0003
>
Permits/Inspections
>
2018-00234 - alarm system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:24:41 PM
Creation date
1/18/2019 3:50:20 PM
Metadata
Fields
Template:
x Address Old
House Number
795
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
795 Old Crystal Bay Road North
Document Type
Permits/Inspections
PIN
2811823340003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
192
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Name: Plan Review and Inspection Checklist <br /> NFPA 13(2010 Edition) Page 5 of 5 <br /> Plan Inspection <br /> System Component Section Review ; Comments <br /> Yes No = Yes! No <br /> Sprinklers continued <br /> 32 Are standard coverage upright sprinklers directly 8.6.5.2.1.8 <br /> attached to less than 3"pipe? <br /> 33 Are extended coverage upright sprinklers directly <br /> 8.8.5.2.1.7 <br /> attached to less than 3"pipe? <br /> 34 Are sprinklers in attic properly located at peak? (4/12 8.6.4.1.4.2 —_—, <br /> pitch) MSFC amendment <br /> 35 Are sprinklers in attic properly located at eave?(4/12 8.6.4.1.4.3 ^- <br /> pitch) MSFC amendment=5'min. <br /> 36 Small room rule properly applied? 8.6.3.2.4 <br /> Hydraulic Calculation Checklist(Non-Storage) Section Yes No Comments <br /> 1 Is the flow test current?<3 years Division Policy <br /> FP-02 2007 <br /> 2 Flow test utilized in the calculations match: <br /> 3 the cover sheet? ✓ <br /> 4 the plan? v <br /> 5 the graph sheet? tr <br /> 6 System demand satisfy 5 psi safety margin? MSFC 903.3.8 ✓ <br /> 7 Correct hose streams been added? 11.2.3.1.2 v <br /> 8 Is the size of the remote area correct? Fig. 11.2.3.1.1 ✓ <br /> • <br /> 9 Is the shape of the remote area correct? 22.4.4.1.1.1 ' <br /> 10 Remote area location correct?(Hyd.most remote) A.22.4.4.6 <br /> 11 Has room design method beenplied correct? 11.2.3.3 .� <br /> 12 Design area QR reduction been applied correctly? 11.2.3.2.3.3 <br /> 13 Is the number of design sprinklers correct? 11.2.3.2.3.2 _ <br /> 14 30%design area increase for sloped ceiling? 11.2.3.2.4 <br /> 15 30%design area increase for dry system? 11.2.3.2.5 <br /> 16 Extra haz.,high temp.reduction correct? 11.2.3.2.6 <br /> 17 Multiple adjustments been applied correctly? 11.2.3.2.7 <br /> 18 All sprinklers in the design area operating? 14.4.4.4.1 & <br /> 14.4.4.4.2 <br /> 19 Is the occupancy correct? 5.1 ✓ J <br /> 20 Is the density correct? 11.2.3.1.1 <br /> 21 Is the coverage area for each sprinkler correct? 8.5.2.1.1 / <br /> Data sheet <br /> 22 Is the minimum GPM for the sprinklers correct? 22.4.4.6.1 /Data <br /> sheet <br /> 23 Is the pressure required for each sprinkler correct?(7 22.4.4.10.1 / <br /> psi min.) Data sheet <br /> Table 6.2.3.1 / <br /> 24 Is the K-factor(s)correct? Data sheet <br /> 25 Sprinklers on the plans same as on calculations? <br /> 26 Is the C-valve for the pipe correct? Table 22.4.4.7 <br /> 27 Are pipe I.D.'s correct? <br /> 28 Pipe sizes on the plans match calculations? <br /> 29 Pipe lengths on the plans match calculations? <br /> 30 All valves and fittings added into calculations? 22.4.3 <br /> 31 Friction loss through the pipe and fittings correct? 22.4.4.7 <br /> 32 Has correct amount of elevation been calculated? A.11.2.3. (Fig. <br /> A.22.3.2(c) <br /> 33 Nodes on calc. sheets match nodes on plans? <br /> 34 Are all the nodes indicated on the plan? <br /> 35 Are the nodes properly connected? -JI <br />