Laserfiche WebLink
DF-52121:E•E-325 <br /> MMF-300(A) Series, <br /> MDF-300 � F��'��TC�`ALarCY1S <br /> Addressable Monitor Modules by Honeywell <br /> � - <br /> General <br /> Four different monitor modules are available for Fire•Lite's <br /> ;.,.�.,:w,.,.,&�i <br /> intelligent control panels to suit a variety of applications. Moni- > `` �,.w,i <br /> tor modules are used to supervise a circuit of dry-contact input ° ` ` t <br /> devices,such as conventional heat detectors and pull stations, �L ! , '°"' � <br /> or monitor and power a circuit of two-wire smoke detectors � y ' � 0�> � <br /> (MMF-302(A)). 1�E"" �µ�. ��M <br /> MMF-300(A)is a standard-sized module(typically mounts to a ��_�-�*� <br /> 4" [10.16 cm] square box) that supervises either a Style D �«� <br /> (Class A) or Style B (Class B) circuit of dry-contact input '�`",�, 5,��-'*� <br /> devices. ,�..�-,��,��.,....�.,,....o <br /> MMF-301(A)is a miniature monitor module a mere 1.3"(3.302 �•�•� ��,.: <br /> cm) H x 2.75" (6.985 cm)W x 0.65" (1.651 cm) D that super- o,'° `` � '�; <br /> vises a Style B(Class B)circuit of dry-contact input devices.Its ,� t,��, J Wp�� - <br /> compact design allows the MMF-301(A) to be mounted in a �,� � ,,,�, <br /> single-gang box behind the device it monitors. a <br /> ;� g <br /> MMF-302(A) is a standard-sized module used to monitor and � �� .,,_;.. _ .___._ __ .,::�;,_;>` <br /> supervise compatible two-wire, 24 volt, smoke detectors on a �'`' - �""�` �` <br /> Style D(Class A)or Style B(Class B)circuit. `' �'� `U <br /> MDF-300(A) is a standard-sized dual monitor module used to MMF-300(A)(Type H) <br /> monitor and supervise two independent two-wire Style B <br /> (Class B) dry-contact initiating device circuits (IDCs) at two supervisory indication at the control panel. Monitored circuit <br /> separate, consecutive addresses in intelligent, two-wire sys- may be wired as an NFPA Style B (Class B)or Style D (Class <br /> tems. A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor <br /> LiteSpeedT"" is a communication protocol developed by (provided)terminates the Style B circuit.No resistor is required <br /> Fire•Lite Engineering that greatly increases the speed of com- for supervision of the Style D circuit. <br /> munication between analog intelligent devices. Intelligent MMF-300(A) OPeRar�oN <br /> devices communicate in a grouped fashion. If one of the <br /> devices within the group has new information, the panel CPU Each MMF-300(A) uses one of the available module <br /> stops the group poll and concentrates on single points. The addresses on an SLC loop. It responds to regular polls from <br /> net effect is response speed greater than five times that of the control panel and reports its type and the status(open/nor- <br /> other communication protocols. mal/short)of its Initiating Device Circuit(IDC).A flashing LED <br /> indicates that the module is in communication with the control <br /> MMF-300(A) Monitor MOdule panel. The LED latches steady on alarm (subject to current <br /> limitations on the loop). <br /> • Built-in type identification automatically identifies this device <br /> as a monitor module to the control panel. MMF-300(A)SPECIFICATIONS <br /> • Powered directly by two-wire SLC loop. No additional Nominal operating voltage: 15 to 32 VDC. <br /> power required. Maximum current draw: 5.0 mA(LED on). <br /> • High noise(EMF/RFI)immunity. Average operating current: 375 NA (LED flashing), 1 com- <br /> • SEMS screws with clamping plates for ease of wiring. munication every 5 seconds,47k EOL. <br /> • Direct-dial entry of address: 01 — 159 on MS-9600 series Maximum IDC wiring resistance: 1500 Ohms. <br /> panels,01 —99 on other compatible systems. <br /> • LED flashes during normal operation and latches on steady Maximum IDC Voltage: 11 Volts. <br /> to indicate alarm. EOL resistance:47K Ohms. <br /> The MMF-300(A) Monitor Module is intended for use in intelli- Temperature range:32°F to 120°F(O�C to 49°C). <br /> gent, two-wire systems, where the individual address of each Humidity range: 10°/o to 93%noncondensing. <br /> module is selected using the built-in rotary switches. It pro- <br /> vides either a two-wire or four-wire fault-tolerant Initiating Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x <br /> Device Circuit (IDC)for normally-open-contact fire alarm and 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x <br /> supervisory devices. The module has a panel-controlled LED 2•125"(5.398 cm)deep box. <br /> indicator. The MMF-300(A) can be used to replace M300(A) <br /> modules in existing systems. MMF-301(A) Mini Monitor Module <br /> MMF-300(A)APPLICAT/ONS • Built-in type identifcation automatically identifies this device <br /> Use to monitor a zone of four-wire smoke detectors, manual as a monitor module to the panel. <br /> fire alarm pull stations, waterflow devices, or other normally- • Powered directly by two-wire SLC loop. No additional <br /> open dry-contact alarm activation devices. May also be used power required. <br /> to monitor normally-open supervisory devices with special • High noise(EMF/RFI)immunity. <br /> DF-52121:E•07/30/2015—Page 1 of 4 <br />