Laserfiche WebLink
• Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power <br /> • Direct-dial entry of address: 01 — 159 on MS-9600 series source. <br /> panels,01 —99 on other compatible systems • High noise(EMF/RFI)immunity. <br /> ___ • SEMS screws with clamping plates for ease of wiring. <br /> 3 14�5 0 � 0 � • Direct-dial entry entry of address: 01 — 159 on MS-9600 <br /> � �g 2 2 series panels,01 —99 on other compatible systems. <br /> 3 12 3 3 • LED flashes during normal operation. <br /> � �� O 4 � O 4 • LED latches steady to indicate alarm on command from <br /> 1 <br /> control panel. <br /> 9 8 � 6 9 8 � 6 The MMF-302(A)Interface Module is intended for use in intelli- <br /> TENS ONES <br /> gent, addressable systems, where the individual address of <br /> ; each module is selected using built-in rotary switches. This <br /> module allows intelligent panels to interface and monitor two- <br /> wire conventional smoke detectors. It transmits the status <br /> Y (normal, open, or alarm) of one full zone of conventional <br /> � � � � detectors back to the control panel. All two-wire detectors <br /> � ) ap being monitored must be UL compatible with the module.The <br /> MMF-302(A) can be used to replace M302(A) modules in <br /> existing systems. <br /> MMF-302(A)AaaucanoNs <br /> Use the MMF-302(A) to monitor a zone of two-wire smoke <br /> The MMF-301(A) Mini Monitor Module can be installed in a detectors. The monitored circuit may be wired as an NFPA <br /> single-gang junction directly behind the monitored unit. Its Style B(Class B)or Sryle D(Class A)Initiating Device Circuit. <br /> small size and light weight allow it to be installed without rigid A 3.9 K Ohm End-of-Line Resistor (provided) terminates the <br /> mounting. The MMF-301(A) is intended for use in intelligent, end of the Style B or D (class B or A) circuit(maximum IDC <br /> two-wire systems where the individual address of each module loop resistance is 25 Ohms). Install ELR across terminals 8 <br /> is selected using rotary switches. It provides a two-wire initiat- and 9 for Style D application. <br /> ing device circuit for normally-0pen-contact fire alarm devices. <br /> The MMF-301(A)can be used to replace M301(A)modules in MMF-302(A)OPERATION <br /> existing systems. Each MMF-302(A) uses one of the available module <br /> MMF-301(A)APPLICATIONs addresses on an SLC loop. It responds to regular polls from <br /> the control panel and reports its type and the status(open/nor- <br /> Use to monitor a single,device or a zone of four-wire smoke maVshort)of its Initiating Device Circuit(IDC).A flashing LED <br /> detectors, manual fire alarm pull stations, waterflow devices, indicates that the module is in communication with the control <br /> or other normally-open dq/;�ontact devices.May also be used panel. The LED latches steady o�,alarm (subject to curcent <br /> to monitor normally-open.,,supervisory devices with special limitations on the loop). ., <br /> supervisory indication at the control panel. Monitored circuiU <br /> device is wired as an NFPA Style B(Class B)Initiating Device MMF-302(A)SPec�FlCATIon►s <br /> Circuit.A 47K Ohm End-of-Line Resistor(provided)terminates Nominal operating voltage: 15 to 32 VDC. <br /> the circuit. Maximum current draw:5.1 mA(LED on). <br /> MMF-$O'I(A�OPERATION Maximum IDC wiring resistance:25 Ohms. <br /> Each MMF-301(A) uses one of the available module p�erage operating current: 270 NA, 1 communication and 1 <br /> addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3.9k eol. <br /> the control panel and reports its type and the status(open/nor- <br /> mal/short)of its Initiating Device Circuit(IDC). EOL resistance:3.9K Ohms. <br /> MMF-301(A)SPECIF�CaT1oNS External supply voltage(between Terminals T10 and T11): <br /> Nominal operating voltage: 15 to 32 VDC. • DC voltage:24 volts power limited. <br /> Average operating current: 350 uA, 1 communication every ' Ripple voltage:0.1 Vrms maximum. <br /> 5 seconds, 47k EOL; 600 NA Max. (Communicating, IDC ' Current:90 mA per module maximum. <br /> Shorted). Temperature range:32°F to 120°F(0°C to 49°C). <br /> Maximum IDC wiring resistance: 1500 Ohms. Humidity range: 10%to 93%noncondensing. <br /> Maximum IDC Voltage: 11 Volts. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x <br /> Maximum IDC Current:450 NA. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x <br /> 2.125"(5.398 cm)deep box. <br /> EOL resistance:47K Ohms. <br /> Temperature range:32°F to 12o°F(o°C to 4s°C). MDF-300(A] Dual Monitor Module <br /> Humidity range: 10%to 93%noncondensing. The MDF-300(A) Dual Monitor Module is intended for use in <br /> Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm)wide x intelligent, two-wire systems. It provides two independent two- <br /> 0.65"(1.651 cm)deep. wire initiating device circuits(IDCs)at two separate,consecutive <br /> addresses.It is capable of monitoring normally open contact fire <br /> Wire length:6"(15.24 cm)minimum. alarm and supervisory devices.The module has a single panel- <br /> controlled LED. <br /> MMF-302(A) Interface Module <br /> • Supports compatible two-wire smoke detectors. <br /> Page 2 of 4—DF-52121:E•07130/2015 <br />