• Page 2 August 11,2014 <br /> 5. Provide equipment manufacturer's specification sheets for the following <br /> pieces of food service equipment: ALL equipment. There is a statement on the <br /> plan application "will drop off pics." Nothing has been received. <br /> 6. Provide the shop drawings for the following custom fabricated items: all custom <br /> equipment. All custom fabricated foodservice equipment must be manufactured to <br /> NSF standards by an NSF-listed fabricator. <br /> 7. All primary food preparation surfaces (preparation tables and counters) in the food <br /> service operation must meet NSF standards, such as stainless steel or solid surfaces, <br /> like CorianO and quartz, like Cambria.0 <br /> 8. The interior and exterior of exposed wood areas of the custom fabricated cabinets <br /> must be covered with a commercial-grade pressure-applied laminated plastic. Any <br /> cutouts into cabinetry must be properly finished with plastic laminate, melamine, or <br /> grommet, no caulk or painted finishes. <br /> 9. Provide sufficient refrigeration is to hold all readily perishable food products at 41° F <br /> or less. <br /> 10. All refrigerated preparation tables must meet the April 1998, NSF standard 7 criteria. <br /> 11. Provide specifications on a NSF approved water heater that can provide an <br /> adequate amount of hot water during peak hot water use periods. The water <br /> heater must be NSF-or NSF/ANSI-listed. <br /> 12. Any used or existing equipment must meet the NSF standards, be listed, and <br /> be in "like new" condition. Please indicate if any of the equipment is existing <br /> or used. <br /> Ventilation/Equipment Installation <br /> 13. All equipment, including millwork cabinets, must be mounted on casters, six-inch <br /> legs, or sealed to a solid masonry base. Enclosed, unfilled bases are not permitted. <br /> Small undercounter dishwashers may be installed on skids for ease in movement for <br /> cleaning. <br /> 14. All heating appliances that generate excessive heat, grease, vapors, condensation, <br /> odors, or fumes must be situated beneath a mechanical exhaust hood. <br /> 15. The hood and canopy construction must meet the applicable standards of the <br /> National Sanitation Foundation, the Uniform Mechanical Code, and the amended <br /> Minnesota Building Code covering commercial kitchen ventilation systems. <br /> 16. Provide properly installed sheets of stainless steel on the wall behind the grease <br /> producing equipment from the bottom of the hood to the top of the floor base cove. <br /> 17. If bar glasses are hung above the customer counter, approved shielding is required to <br /> protect the glassware. <br /> Plumbing <br /> M {.".�i."s<e,E�(3�?')Tfit,f�� 1..;';�() SY."-4��# yr 1{''t1 �Dtf(.S.�al. <br />