Laserfiche WebLink
• Page 3 August 11,2014 <br /> 18. A licensed plumber shall install all plumbing according to the Minnesota Plumbing <br /> Code. In addition, plumbing plans must be submitted to the Minnesota Department of <br /> Labor and Industry, Plumbing and Engineering Unit, 443 Lafayette Road North, St. <br /> Paul, MN 55155-4343 or a municipality with the delegated plumbing inspection <br /> program for review and approval prior to installation. <br /> 19. Check with the local municipality for their regulations regarding grease trap <br /> requirements. If a grease trap is installed, the lid should be mounted flush with <br /> the floor and it shall be accessible for cleaning. <br /> Sinks <br /> 20. Either adequate space (12 inches) or a shield must be provided between the <br /> preparation/hand sink and a preparation table to preclude contamination by <br /> splash. <br /> 21. The plans and specifications did not depict a ufility service sink. Provide a <br /> mop sink for proper disposal of mop water. <br /> 22. For hot water sanitizing, a minimum of three drying rack spaces is required. For <br /> chemical sanitizing, a minimum space for five dish racks is required. <br /> Storage <br /> 23. Adequate approved NSF shelving for the food service operation must be <br /> provided to ensure that food products, utensils, or single service articles are <br /> stored at least six inches off the floor. <br /> 24. Provide an area for storage of employees' personal belongings that is separate <br /> form food, clean equipment, and single service supplies. Employee lockers <br /> must be wall mounted or on six-inch legs. <br /> 25. The food storage shelving used in the walk-in refrigerators must be NSF <br /> approved stainless steel, factory pre-coated epoxy or Metroseal�for example. <br /> Chrome or zinc-plated shelving without an approved factory applied hard- <br /> baked protective coating is not approved for this purpose. <br /> 26. Provide a separate storage area that is not adjacent to or above food or food <br /> service items for cleaning chemicals. <br /> 27. Is there a remote storage area? <br /> Room Finishes <br /> 28. The walls and ceilings in the food preparation, utensil washing and toilet room areas <br /> must be smooth, durable, non-absorbent, and easily cleanable such as stainless <br /> steel, ceramic tile, or fiberglass reinforced panels (FRP). In areas where paint is <br /> permittable, the finish shall be light in color, smooth, durable, and easily cleanable <br /> (e.g. high gloss enamel). <br /> 29. The floors in the food preparation, food storage, utensil washing and toilet rooms <br /> must be of a smooth durable material with an integral coved base at the wall/floor <br /> ti. f:3,�i9i{)��l z3l�::i.� y i':Ill( 1 -�r;.'€�'�.4 pt�.'zi#�<7;'7r>> <br />