My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
report of Geotechnical Exploration-1991
Orono
>
Property Files
>
Street Address
>
S
>
Shoreline Drive
>
3333 Shoreline Drive- 20-117-23-11-0024
>
Misc
>
report of Geotechnical Exploration-1991
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:47:46 PM
Creation date
11/30/2018 12:40:07 PM
Metadata
Fields
Template:
x Address Old
House Number
3333
Street Name
Shoreline
Street Type
Drive
Address
3333 Shoreline Drive
Document Type
Misc
PIN
2011723110024
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,._ <br /> Page 7 - #4220 91-1043 <br />" Standard Proctor density. Available information indicates that the excavation-refill system ' <br />: extended beyond the limits of the present construction to provide a ,1:1 lateral excavation , <br /> oversize as measured from elevation of pertinent foundation elements. <br />; In our opinion, the su�cial fill, topsoil and softer portions of the fine alluvium should ; <br /> not be relied upon for structural support. At the location of boring. #3, located very <br />-- near the southwest corner of the existing building, the fill encountered at depth appears <br />� to consist of moderately well-compacted fill placed during the excavation-refill earthwork <br /> for construction of the existing building. The results of laboratory testing performed on <br />_ selected fill samples indicates the present dry density of the fill is comparable at this <br /> location to the dry densities obtained at compaction test locations performed during the <br />� initial earthwork. <br /> r We recommend the in-place fill, topsoil and soft portions of the fine alluvium be <br /> y removed from the planned building area. The excavation should be extended beyond the <br />� edge of the planned building a minimum of 1' for each depth of excavation required <br /> below planned foundation grade (i.e., 1:1 lateral oversize). The minimum depth of <br />� excavation required at the boring locations is indicated in the following tabulation. <br />� Actual depth of excavation required will likely vary throughout the site, especially within <br /> the presently inaccessible portions of the site to the south of the planned building and <br /> the west edge. <br />
The URL can be used to link to this page
Your browser does not support the video tag.