My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Re: plan review notes/2004
Orono
>
Property Files
>
Street Address
>
S
>
Shadywood Road
>
2377 Shadywood Road - 17-117-23-44-0009
>
Correspondence
>
Re: plan review notes/2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:44:11 PM
Creation date
10/9/2018 11:06:14 AM
Metadata
Fields
Template:
x Address Old
House Number
2377
Street Name
Shadywood
Street Type
Road
Address
2377 Shadywood Road
Document Type
Correspondence
PIN
1711723440009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � �3 77 ��,�r��z� /�� <br /> , o�o �9a� <br /> - y � <br /> Date; 8-1-2005 <br /> Plan Review Notes <br /> Address; 2377 Shadywood <br /> Project; Finish shell into coffee shop <br /> Architect; Architectural Alliance <br /> Contractor; Verne V Olson Inc. � <br /> Owner; Christine Valerius <br /> Lessee; Caribou Coffee Co. Inc. <br /> Inspector; Lyle Oman ��. <br /> Occupancy Classification; I.B.C. section 303.1 A-2 Occupancy (inain Floor and luncl�/meeting <br /> room on second floor) <br /> I.B.C. section 304.1 B occupancy ( office portion of second floor ) <br /> Construction type; VB <br /> Location on property; > 30' to property lines, no requirements <br /> Allowable Height and floor area; <br /> Height, 1 story Max- 2 story allowed with sprinkler -proposed 2 story <br /> Basic allowable floor area - 9000 sq. ft. - 4256 proposed <br /> Means of egress; Occupant load -Basement; 800 square feet clivided by 300 = 2 occupants <br /> -1 S` floor <br /> Kitchen - 513 divided by 200 = 2.5 occupants <br /> Restaurant area- 565 divided by 15 = 37.6 occupants <br /> Porch - 103.5 divided by 15 = 6.9 occupants <br /> _�"a floor <br /> Luncl�/ meeting room - 194 divided by 1�= 12 occupants <br /> Office spaces-847 divided by 100 = 8.47 occupants <br /> Egress width; table 10032.3 <br /> Basement- 2 times .15 = .3 <br /> 15` floor - 40 times .15 = 6 <br /> 2"d floor - 20.4 times .15 = 3 <br /> Proposed exceeds total required <br /> Number of exits; table 1004.2.1 Group A <50 occupants req. 1 exits -4 proposed <br /> Requirements; <br /> -I.B.C. table 302.3.3 requires a two hour separation between group A2 and group B <br /> occupancies - I.B.C. 302.3.3 allows a reduction of one hour when the building is provided <br /> with a sprinkler system <br /> -I.B.C. table 71�.2 i•cquires one hoily door assemblies in a one hour separatior.. Provide <br /> plan on ho�v separation will be accomplished prior to construction <br /> -I.B.C. 10032.12.1 Guards required to be 42" hiQh when more than 30" of arade <br />
The URL can be used to link to this page
Your browser does not support the video tag.