�, 03 3 7 7 ��d� �� <br /> , ` . , �'o g9a� <br /> -I.B.C. 1003.2.2.5 Occupant load signs required <br /> -I.B.C. 1003.3.1.4 Floor elevations must be the same on each side of doors <br /> -I. B.C. 1003.3.3.2 Stairways shall have a min. head room of 80" <br /> -LB.C. 1208.1 Requires crawl spaces to have an access opening not less than 18" by 24" <br /> -I.B.C. 2902.1 as amended by state code section 1305.2902 .2 Where plumbing fixtures are <br /> required, separate facilities are required for each sex <br /> -I.B.C. table 2902.1 requires one drinking fountain <br /> -Drinlcing fountain must be in compliance with state code section 1341.0446 - <br /> -I.B.C. 1209 Requires toilet room floors to be a smooth, hard, nonabsorbent surface that <br /> extends up the wall a min. of 6" <br /> -I.B.C. 1209.2 Requires walls within 2 feet of L�rinals and water closets to be a smooth, <br /> hard, nonabsorbent surface to a height of 4 feet above the floor <br /> - Door hardware must be in compliance with section 1341.0442 subp. 9 <br /> -State code section 1341.0520 Requires counters to be accessible in compliance with <br /> section1341.0480 � p7 <br /> _ . (Z,ry�`' �.Z.'t' <br /> ��0. <br />