My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Re: fire alarm system
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0795 Old Crystal Bay Road North - 28-118-23-34-0003
>
Correspondence
>
Re: fire alarm system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:24:43 PM
Creation date
3/14/2018 11:28:29 AM
Metadata
Fields
Template:
x Address Old
House Number
795
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
795 Old Crystal Bay Road North
Document Type
Correspondence
PIN
2811823340003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M OR A NDUM <br /> 111 <br /> WOLD ARCHITECTS-01.0 <br /> AND ENGINEERS <br /> 305 ST. PETER STREET <br /> Sr. PAUL. MN 55102 <br /> 651.227.7773 <br /> TO: Meeting Attendants FAX 651.223.5646 <br /> -TUN) <br /> 25 SOUril GRovE AVENUE <br /> FROM: Tearinie Nielsen I U" SI;ITE 500 <br /> Ei(,iv II. 60120 <br /> 84'.608.2600 <br /> DATE: May 8, 2001 <br /> I..AX 8-1'.605.265-i <br /> (V AY'\C'.AA((I.I):AE.( O.(I <br /> COMM. No: Comm. No. 01059 <br /> VI,AI1.R1 AA OLU.Af. coo <br /> SUBJECT: Orono Public Schools, ISD 278-Fire Alarm Remodel 7 <br /> High School and Intermediate/Elementary School <br /> Meeting at Orono High School and Intermediate School to discuss fire alarm system <br /> requirements. <br /> Attendants: <br /> Bill Meyer, Orono Fire Marshal <br /> John Ostlund, Coordinator of Building and Grounds—Orono Schools <br /> Vaughn Dierks, Wold Architects and Engineers <br /> Tearinie Nielsen, Wold Architects and Engineers <br /> The following items are comments and recommendations for the Fire Alarm <br /> Systems based on Bill Meyer's review: <br /> High School <br /> Aid <br /> 1. The existing fire alarm system will be replaced with a fully addressable system <br /> including horn/strobe devices installed throughout the building per ADA. <br /> 2. One new FACP will replace the two existing panels located in the mechanical <br /> room near the gym. <br /> 3. There will be(3)remote annunciator panels installed. There will be recessed <br /> FAA's located at the Music Room entry and the"Main Entry." A surface mounted <br /> FAA will be installed in the Maintenance Office. Bill reviewed and approved <br /> locations. <br /> 4. There will be manual pull stations installed only at the Kitchen/Maintenance area <br /> door, in the basement lab office,and the Main Office. The existing pull stations <br /> will be removed. <br /> 5. The exterior fire alarm horn will be replaced with a horn/strobe device. <br /> 6. Smoke detectors will be installed in the gym mezzanine area. Smoke detectors <br /> will not be required in the gym per Bill. <br /> 7. Heat detectors are not required in sprinkled storage rooms(Per Bill Meyer). <br /> 8. The basement open storage area will have smoke detection and horn/strobes <br /> located through the center of the space only. <br /> 9. Wold to verify sprinkler system for possibility of installing additional flow <br /> switches(FS) for each floor. The existing FS near the new media center will be <br /> connected as required. <br /> 10. The existing addressable devices located in the media center will be reconnected to <br /> new FACP. Existing devices to be reprogrammed accordingly. <br />
The URL can be used to link to this page
Your browser does not support the video tag.