My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Re: work being done at hse-1996
Orono
>
Property Files
>
Street Address
>
L
>
Loma Linda Avenue
>
1040 Loma Linda Avenue - 08-117-23-23-0028
>
Correspondence
>
Re: work being done at hse-1996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:42:52 PM
Creation date
5/30/2017 1:20:26 PM
Metadata
Fields
Template:
x Address Old
House Number
1040
Street Name
Loma Linda
Street Type
Avenue
Address
1040 Loma Linda Ave
Document Type
Correspondence
PIN
0811723230028
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r �• /(�� `���, ' ��� <br /> 50 highland avenue excelsior, minnesota 55331 � <br /> � <br /> �h�z, 1�6 � . kilstofte <br /> � associates <br /> � architects <br /> Mr. Bart Roeglin te1.612•470•o8os <br /> Bart Roeglin Bu�ding&Remodeling icwin h.kilstotte <br /> 2260 Westedge Boulevard president <br /> Mound,Minnesota 55364 <br /> Subject: Holcombe House <br /> Reinforcing of Existing Wood Beam Near Dining�Area <br /> Dear Bart, <br /> Since the decision by Doug Holcombe to leave the dining room as is and not expand it, the steel <br /> beam shown m our plans w�l not be required. We are assuming that the existing wood beam is a <br /> 6"x 12" timber, and the addition of the�w column reduces its span from 20' to two spans, one <br /> of'7' and one of 13'. With the reduced span this beam is st�l inadequate a�d w�l require one ply <br /> of gang lam 1 3/4 z 11 1/4 glued and nailed to one side. <br /> If it is found that this beam is a 4"x 12" and not a 6"x 12", add one m�re gang lam of the same <br /> size. Gang lam's should have an Fb of 3100 P.S.I. � <br /> If you aze going to use a steel adjust-a post in lieu of a standard 3" steel pipe column at the new <br /> column location,the adjust-a post must have a capacity of 10 kips. <br /> We have checked the existing W 10 x 68 beam at the first�oor and it has adequate capacity f�r . <br /> this change. � � . <br /> Sincerely yours, _ <br /> I�LLSTOFTE ASSOCIATES,INC. <br /> �`•� <br /> H. K�7stofte <br /> � <br /> cc: Doug Holcombe <br /> R <br />
The URL can be used to link to this page
Your browser does not support the video tag.