My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Re: work being done at hse-1996
Orono
>
Property Files
>
Street Address
>
L
>
Loma Linda Avenue
>
1040 Loma Linda Avenue - 08-117-23-23-0028
>
Correspondence
>
Re: work being done at hse-1996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:42:52 PM
Creation date
5/30/2017 1:20:26 PM
Metadata
Fields
Template:
x Address Old
House Number
1040
Street Name
Loma Linda
Street Type
Avenue
Address
1040 Loma Linda Ave
Document Type
Correspondence
PIN
0811723230028
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� -. <br /> 50 highland avenue excelsior, minnesota 55331 <br /> - <br /> . , � I� <br /> . February 26, 1996 <br /> kilstofte <br /> associates <br /> �. Bart Roeglin architects <br /> Bart Roeglin Building&Remodeling . ts�. 6t 2•a�o•osos <br /> 2260 Westedge Boulevard trwtn t,.kilstofte <br /> � Mound, Miimesota 55364 president <br /> Subject: Holcombe House � <br /> Existing Flat Roof Over Garage <br /> Dear Bart, <br /> Existing 2"x 8" framing at 16" o.c., Fb 1200, spatuiing approximately 12' will hold 54#/s.f. total <br /> load at L/360 deflection. Allowing for live load of 40#/s.f. and dead load of 10#/s.f. leaves excess <br /> capacity of 4#/s.f. <br /> The cerrter beam at the garage, 5 1/2" x 13" or 6" x 14" nominal at a span of 21.33' will carry <br /> onty 294#Ilin.ft. at a deflection of L/360. The total load of 50#/s.f. at 12' span results in a total <br /> load of 600#/lin.ft. The excess load of 306#/lin.ft. can be supported by the addition of two gang- <br /> lam beams 1 3/4" x 14" glued and nailed on both sides of the presetrt beam. The total load <br /> capacity of these beams is 384#/lin.ft. added to the 294#/lin.ft. carried by the original beam <br /> making a total capacity of 778#/lin.ft,, or 178#/liu.ft. excess capacity. Live load deflection at <br /> L/360 is 480#/lin.ft. The capacity of the three members together is 550#/lin.ft. at L/360. <br /> Additional studs must be added under the beams at bearing. The gang lam beams by Structural <br /> Wood Corporation used in calculations, have an Fb of 3100 P.S.I. and an"E"of 2.0. <br /> The beam in the garage at the east wall nearest the dining room has only�about 2/3 of the load of <br /> the center beam. I think it would be a good idea to add one 1 3/4" x 14" gang-lam glued and <br /> nailed to this beam This would preverrt atry additional load to be transfen�ed to the first floor <br /> structure through the stud wall below it. <br /> Yours truly, • • <br /> KILSTOFTE ASSOCIATES, INC. <br /> , I ofte . . . <br /> cc: Doug Holcombe <br />
The URL can be used to link to this page
Your browser does not support the video tag.