1989-04-25 Inspection Report, Fire Sprinkler
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
1700 Fox Street - 03-117-23-41-0007
>
Paperwork from old PID# 03-117-23-41-0003
>
Permits/Inspections
>
1989-04-25 Inspection Report, Fire Sprinkler
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2026 3:22:02 PM
Creation date
4/29/2026 3:17:24 PM
Metadata
Fields
Template:
x Address Old
House Number
1700
Street Name
Fox
Street Type
Street
Address
1700 Fox Street
PIN
0311723410003
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EAGLE FIRE PROTECTION CO. <br />2335 NEVADA AVE. NO. <br />MINNEAPOLIS, MN. 55427 <br />PH. 546-2335 <br />REPORT OF INSPECTION <br />INSPECTION CONTRACT NO. 14033 <br />REPORT T0: MACMILL AN TENNIS BUILDING/ LOCATION: <br />STREET: 170 FOX STREET INSPECTOR: DALE BISTODEAU <br />CITY/STATE: WAYZATA, MN ZIP:55391 DATE: APRIL 25, 1989 <br />-------------------------------------------------------------------------------- <br />OWNER'S SECTION (TO BE ANSWERED BY OWNER OR OCCUPANT) <br />A. Explain any occupancy hazard changes since the previous inspection. <br />B. Describe fire protection modifications made since last inspection. <br />C. Describe any fires since last inspection. <br />D. When was the system piping last checked for stoppage, corrosion or foreign <br />material?. <br />E. When was the dry -piping system last checked for proper pitch? <br />F. Are dry valves adequately protected from freezing? <br />Signature: Title: Date: <br />------------------------------------------------------------------------------- <br />INSPECTOR'S SECTION (ALL RESPONSES REFERENCE CURRENT INSPECTION) <br />NA - NOT APPLICABLE <br />1. <br />General <br />a. <br />Is the building occupied? YES <br />b. <br />Are all systems in service? YES <br />c. <br />Is there a minimum of 18 in. 1457 mm) clearance between the top of the <br />storage and the sprinkler deflectors? YES <br />d. <br />Does all electrical heat tape appear tote satisfactory? <br />e. <br />Does the rand hose on the sprinkler system(s) appear to be satisfactory? <br />N/A <br />2. <br />Contr—ol Valves (See Item <br />a. <br />Are all spr. , kler system control valves and all other valves in the <br />appropriate open or closed position? YES <br />o. <br />Are all control valves in the opeci posi ur, locked, sealer or equippf d <br />with tamper switch? YES <br />3. <br />Water Supplies (See Item 16.) <br />a. <br />Was a water flow test of main drain made at the sprinkler riser(s):' <br />YES <br />4. <br />Tanks, Pumps, Fire Department Connections <br />a. <br />Are fire pumps, gravity tanks, reservoirs and pressure tanks in good <br />condition and properly maintained? YES <br />b. <br />Are fire department connections in satisfactory condition, couplings <br />free, caps in place, and check valves tight? YES <br />Are <br />they accessible and visible? YES <br />EN <br />