Inspection Report No.14033 Eagle Fire Protection Co. Page 2 <br />Report <br />To:MACMILLAN TENNIS <br />-------------------------------------------------------------------------------- <br />5. <br />Wet <br />Systems <br />a. <br />Are cold weather valves (O.S.& Y.) in the appropriate open or closed <br />position? <br />b. <br />Have antifreeze syscam solutions been tested? N/A <br />c. <br />Were the antifreeze test results satisfactory? _N7A <br />d. <br />In areas protected by wet system (s) , does the building appear to be <br />properly heated in all areas, including blind attics and perimeter areas <br />where accessible? YES Do all e-terior openings appear to be protected <br />against freezing? YES <br />6. <br />Dry <br />Systems (See Items 11 to 13.) <br />a. <br />Are dry valve(s) in service? YES <br />b. <br />Are the air pressures and priming water levels in accordance with the <br />manufacturer's instructions? YES <br />c. <br />Has the operation of the air or nitrogen supplies been tested? YES <br />d. <br />Were low points drained during this inspection? YES <br />e. <br />Did quick -opening devices operate satisfactorily? <br />f. <br />Did the dry valve(s) trip properly during the trip pressure test? YES <br />g. <br />Did the heating equipment in the dry -pipe valve room(s) operate at tTie <br />time •f inspection? YES <br />7. <br />Special S�, . L;ems <br />a. <br />Did the deluge or pre -action valves operate properly during testing? <br />b. <br />Did the heat-respons�:e devices operate properly during testing? N/A <br />C. <br />Did the supervisory devices operate during testing? N/A <br />8 . <br />Alarms <br />a. <br />Did water motor(s) and gong(s) test satisfactorily? <br />b. <br />Did electric alarm(s) test satisfactorily? YES <br />C. <br />Did supervisory alarm service test satisfact-o-r-lly? YES <br />9. <br />Sprinklers <br />a. <br />Are all sprinklers free from corrosion, loading or obstruction to spray <br />discharge? YES <br />b. <br />Are sprinklers less than 50 years old? YES <br />c. <br />Is stock of spare sprinklers available? NO <br />d. <br />Does the exterior condition of sprinkler system appear to be <br />satisfactory? YES <br />e. <br />Are sprinklers improper temperature ratings for their locations? <br />YES <br />10. <br />Explain any "NO" answers and/or co c;.ta:fi0 HEAD COX <br />11. Date dry pipe valve trip tested (control valve partially open) 4/25/89 <br />(See Trip Test Table attached.) <br />12. Date dry pipe valve trip tested (control valve fully open) <br />(See Trip Test Table attached.) <br />13. Date quick -opening device tested N/A (See Trip Test Table attached.) <br />14. Date deluge or preaction valve tested N/A (See Trip Test Table attached.) <br />