1989-04-25 Inspection Report, Fire Sprinkler
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
1700 Fox Street - 03-117-23-41-0007
>
Paperwork from old PID# 03-117-23-41-0003
>
Permits/Inspections
>
1989-04-25 Inspection Report, Fire Sprinkler
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2026 3:22:02 PM
Creation date
4/29/2026 3:17:24 PM
Metadata
Fields
Template:
x Address Old
House Number
1700
Street Name
Fox
Street Type
Street
Address
1700 Fox Street
PIN
0311723410003
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Inspection Report No.14033 Eagle Fire Protection Co. Page 2 <br />Report <br />To:MACMILLAN TENNIS <br />-------------------------------------------------------------------------------- <br />5. <br />Wet <br />Systems <br />a. <br />Are cold weather valves (O.S.& Y.) in the appropriate open or closed <br />position? <br />b. <br />Have antifreeze syscam solutions been tested? N/A <br />c. <br />Were the antifreeze test results satisfactory? _N7A <br />d. <br />In areas protected by wet system (s) , does the building appear to be <br />properly heated in all areas, including blind attics and perimeter areas <br />where accessible? YES Do all e-terior openings appear to be protected <br />against freezing? YES <br />6. <br />Dry <br />Systems (See Items 11 to 13.) <br />a. <br />Are dry valve(s) in service? YES <br />b. <br />Are the air pressures and priming water levels in accordance with the <br />manufacturer's instructions? YES <br />c. <br />Has the operation of the air or nitrogen supplies been tested? YES <br />d. <br />Were low points drained during this inspection? YES <br />e. <br />Did quick -opening devices operate satisfactorily? <br />f. <br />Did the dry valve(s) trip properly during the trip pressure test? YES <br />g. <br />Did the heating equipment in the dry -pipe valve room(s) operate at tTie <br />time •f inspection? YES <br />7. <br />Special S�, . L;ems <br />a. <br />Did the deluge or pre -action valves operate properly during testing? <br />b. <br />Did the heat-respons�:e devices operate properly during testing? N/A <br />C. <br />Did the supervisory devices operate during testing? N/A <br />8 . <br />Alarms <br />a. <br />Did water motor(s) and gong(s) test satisfactorily? <br />b. <br />Did electric alarm(s) test satisfactorily? YES <br />C. <br />Did supervisory alarm service test satisfact-o-r-lly? YES <br />9. <br />Sprinklers <br />a. <br />Are all sprinklers free from corrosion, loading or obstruction to spray <br />discharge? YES <br />b. <br />Are sprinklers less than 50 years old? YES <br />c. <br />Is stock of spare sprinklers available? NO <br />d. <br />Does the exterior condition of sprinkler system appear to be <br />satisfactory? YES <br />e. <br />Are sprinklers improper temperature ratings for their locations? <br />YES <br />10. <br />Explain any "NO" answers and/or co c;.ta:fi0 HEAD COX <br />11. Date dry pipe valve trip tested (control valve partially open) 4/25/89 <br />(See Trip Test Table attached.) <br />12. Date dry pipe valve trip tested (control valve fully open) <br />(See Trip Test Table attached.) <br />13. Date quick -opening device tested N/A (See Trip Test Table attached.) <br />14. Date deluge or preaction valve tested N/A (See Trip Test Table attached.) <br />