Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
-�o���. <br /> � . � <br /> ; o o��. <br /> �,,, <br /> ��� � . CITY of OR�NO <br /> , r, �:,, <br /> +� s,'; ` P;�•;� . �+ � � <br /> � � },��, �.,� ,` ��, '. Municipal Offices <br /> �,� ; ta�G Street Address: �iSa-a4q'�b� � Mailing Address: <br /> '9$ESHpg' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: I D�`� S,�.r`n°l �;1� � <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (i-3): � <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the locadon,design and construction standazds of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requ'uement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> ( 3 J'`NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> �Jor may not meet all the location,design,or conshvction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> �6�Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> `'� Tank was last pumped �7���i'� 1 ). <br /> Make sure septic tanks are pumped throu�h manhole and not throu¢h white inspection pipes. This allows for the proper <br /> cleaning. Keep water softner and iron filter dischar¢e out of septic svstem to prolon¢life of drainfield. Ask pumper to test <br /> alarm float to verifv alarm is still workin¢in vour house. The alarm warns owner that seata¢e is about to backua into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-101: <br /> � Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within 90 days. <br /> COMMENTS: �f4-.��-,t�� �S �r.- �d.— 1:�rs- �-- t`����-- b� r <br /> C;�'�\o' c< �,--� \Z.-�1-10 6 7� t�,.p,s���L -jrn,.,�i� S�^r,�.�� <br /> 0� - <br /> ._-- <br /> 1 � -�-oy � <br /> Date of Inspection Matt Bolterman - Septic System Inspector <br /> Notc In the event that diis inspection report is used to satisfj� the requirements for a mortgage or other transf'er ot�properh. be advised tliat this report dues <br /> nu� �suaruntee or eertitj that an e�istine system ��•ill continue to Cunclion prop¢rl��, hut is• mereh an opinion of the adequac� of the s�stem under currcnt <br /> �un�ition;based on the avail�blc inlunnation. <br />