Laserfiche WebLink
���'�5���f�;'� <br /> MINNESOTA DEPARTMENT OF HEALTH QUG � 4 200� <br /> Division of Environmental Health <br /> REPORT ON PLANS �4�Y�:3r-����o <br /> Plans and specitications on plumbing: St. Edward the Confessor Episcopal Church, 865 North Ferndale Road, <br /> Orono, Hennepin County, Minnesota, Plan No. 050483 <br /> OWNERSHIP: St. Edward the Confessor Episcopal Church, 865 Noth Femdale Road, Orono, <br /> Minnesota 55323 <br /> SUBMITTER(S): Gilbert Mechanical Contractors, Inc., 4451 West 76th Street, Minneapolis, Minnesota 55435 <br /> Plans Dated: <br /> Date Received: August 4, 2004 <br /> Date Reviewed: August 19, 2004 <br /> SCOPE: This review is limited to the design of this particular project only insofar as the provisions of the <br /> Minnesota Plumbing Code, as amended, apply, and does not cover the water supply or sewerage system to which <br /> this plumbing system is connected. The review is based upon the supposition that the data on which the design is <br /> based are correct, and that necessary legal authority has been obtained to construct the project. The <br /> responsibility for the design of structural features and the eiticiency of equipment must be taken by the project <br /> designer. Approval is contingent upon satisfactory disposition of any requirements included in this report. <br /> Special care should be taken to insure that the material and installation of the plumbing system are in accordance <br /> with the provisions of the Minnesota Plumbing Code. A copy of the approved plans and specifications should <br /> be retained at the project location for future reference. <br /> A set of the identii-ied plans and specifications is being returned to Gilbert Mechanical Contractors, Inc. <br /> INSPECTIONS: All plumbing installations must be tested and inspected in accordance with the requirements of <br /> the Minnesota Plumbing Code. As specified in Minnesota Rules, part 4715.2830, no plumbing work may be <br /> covered prior to completing the required tests and inspections. Provisions must be made for applying an air test <br /> at the tirrie of the roughiug-in inspection as outlined in Minnesota Rules, part 47152820, subpart 2, of the code. <br /> A manometer test, as specified in Minnesota Rules, part 47152820, subpart 3, is required at the time of the <br /> finished plumbing inspection. It is the responsibility of the contractar/installer to notify the Minnesota <br /> Department of Health when an installation for a state contract job, licensed facility, or project in an area where <br /> there is no local administrative authority is ready for an inspection and test. To schedule inspections, contact the <br /> state plumbing standards representative far your region, or call the metro office inspection hotline at 1-800-926- <br /> 6216 (7:30 a.m to 9 a.m), or 651/215-0836 (8 a.m to 9 a.m) on Monday, Wednesday or Friday. <br /> REQUIREMENT(S): <br /> 1. Elevator pit drains must discharge to the sanitary sewer through an indirect connection which precludes the <br /> possibility of sewage backup into the pit. If a sump is used, a dry-pan drain must discharge to the sump. <br /> The waste pipe from the sump shall discharge indirectly to the sanitary waste system through a fixture that <br /> is trapped and vented (see Miru�esota Rules, part 4715.1305). Please see the enclosed handout for specifics <br /> on elevator pit drain construction. <br /> 2. The sump must be designed in accordance with Minnesota Rules, part 4715.2440. The following items <br /> must be included in the construction of the sump: <br /> a. A gate valve and check valve must be provided on the sump pump discharge line, must be accessible <br /> and located outside of the sump. <br /> b. An air-tight cover must be provided far the sump. <br /> 3. A urinal may not discharge to a water closet vent(see Minnesota Rules,part 4715.2580). The urinal(s) must be <br /> provided with individual waste and vent connections. The sanitary sewer isometric on Sheet No. P6 shows the <br /> water closet (P-2) and the urinal (P-3) on the top floor to have corrunon waste and vent connections. <br />