My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
From Dept of Health on plmb plans
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Road North
>
865 Ferndale Road North - 25-118-23-44-0002
>
Correspondence
>
From Dept of Health on plmb plans
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:16:09 PM
Creation date
9/7/2016 1:58:55 PM
Metadata
Fields
Template:
x Address Old
House Number
865
Street Name
Ferndale
Street Type
Road
Street Direction
North
Address
865 Ferndale Road North
Document Type
Correspondence
PIN
2511823440002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
St. Edward the Confessor Episcopal Church <br /> Plumbing <br /> Plan No. 050483 <br /> Page 2 <br /> August 19, 2004 <br /> 4. Faucets equipped with threaded hose connections must be provided with approved backflow preventers. This " <br /> shall include the faucet for the janitor's sink. <br /> 5. The vent pipe opening from a soil or waste pipe may not be below the weir of the trap. The fixture drain lines <br /> must connect to the vertical sanitary drain with a tee connection rather than a wye connection as indicated in <br /> the waste and vent riser diagrams (see Minnesota Rules, part 4715.2620> subpart 2). <br /> 6. The copper water distribution piping must meet ASTM Standard B 88 (see Minnesota Rules, part 4715.0520). <br /> The plumbing specification list on Sheet No. P1 (Item 3F)incorrectly refers to ASTM Standard 388 for water <br /> distribution piping. <br /> 7. Pipe hanger and support spacing shall conform to the requirements specified in Minnesota Rules, <br /> part 4715.1430. <br /> 8. The plans and specitications were prepared by a licensed master plumber. The plumber who has prepared the <br /> plans is the only one that can use the plans for construction. If another plumber is contracted to install the <br /> plumbing, they must submit their own plans and specifications for the project. <br /> NOTE(S): <br /> 1. The scope of this project consists of the remodeling of an existing building. The plumbing installation includes <br /> water closets, urinals,lavatories,kitchen sinks, water coolers, a mop sink, a water heater, a sump pump, and <br /> floor drains. <br /> 2. This facility will be served by existing municipal sewer and water service connections. <br /> Authorization for construction in accordance with the approved plans may be withdrawn if construction is not <br /> undertaken within a period of two years. The fact that the plans have been approved does not necessarily mean that <br /> recoinmendations or requirements for change will not be made at some later time when changed conditions, <br /> additional information, or advanced knowledge make improvements necessary. <br /> Ap roved: <br /> Todd Schaefer <br /> Public Health Engineer <br /> Environmental Health Services Section <br /> P.O. Box 64975 <br /> St. Paul, Minnesota 55164-0975 <br /> 651/215-1249 <br /> TDS 1ss <br /> Enclosure <br /> cc: Gilbert Mechanical Contractors, Inc. <br /> St. Edward the Confessor Episcopal Chy.rch <br /> Mr. Lyle Oman, Plumbing Inspector � <br /> File <br />