My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016-01123 - pool
Orono
>
Property Files
>
Street Address
>
O
>
Orono Lane
>
1380 Orono Lane - 02-117-23-34-0012
>
Permits/Inspections
>
2016-01123 - pool
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:10:07 PM
Creation date
5/2/2018 9:37:13 AM
Metadata
Fields
Template:
x Address Old
House Number
1380
Street Name
Orono
Street Type
Lane
Address
1380 Orono La
Document Type
Permits/Inspections
PIN
0211723340012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
acr-c( ZEXJ'+ iw•a; P.02.'02 <br /> . .. <br /> • <br /> • <br /> PERIMETER DEFLECTION TEST <br /> The perimeter deflection test was conducted on both Cover-Pool safety covers in <br /> accordance with section 9.2 of ASTM ES 13. With a 50 lb. weight placed 4' from the <br /> edge of the pool on top of the safety covet, the test object was unable to pass through <br /> any opening at the perimeter of the pool. Both Cover-Pool safety covers met the <br /> performance requirements for the perimeter deflection test as outlined In ASTM ES 13 <br /> section 7.2. <br /> SURFACE DRAINAGE TEST <br /> On June 12. 1990. the surface drainage test was conducted on a Cover-Pool safety <br /> cover which was installed on a local private pool. The tracidng system was an under <br /> track system. The pool dimensions were 14.1Tx42.5'. The surface drainage test was <br /> conducted in accordance with ASTM ES 13 section 9.3. Water was applied evenly at <br /> • a rate of 11.7 gpm per 1000 sq. ft. A small sump pump, with discharge capacity of 20 <br /> gpm. was placed at one end of the safety cover with the discharge hose snaking the <br /> length of the pool. on top of the safety cover, and discharging at the opposite end from <br /> • the pump. The water was applied for 30 minutes with the pump on and In place. The <br /> water was then shut off and the pump was allowed to run for an additional 30 minutes. <br /> The test mannequin (Timmy) was then placed upon the safety cover. At the end of 3 <br /> minutes after placing Timmy upon the safety cover, an unsafe amount of water as <br /> described In ASTM ES 13 section 9.3.1 did not exist. The Cover-Pool safety cover met <br /> the safety requirements as outlined in ASTM ES 13 section 7.3. <br /> All safety covers and equipment tested were standard as provided by Cover-Pools inc. Safety covers <br /> were Installed according to Cover-Adds, inc. standard installation criteria. <br /> Inspector. Jerry Hall <br /> NINi1ae UO IMUCIAILI ow?to mono SUMO TOMO. <br /> ARM KW NOT SIN PACOUNa;NNW"N MLAVICauf <br /> NW=PellMKaNt MY PM.INC. <br /> Respectfully submitted, <br /> Professional Servlcti Industries. Inc. <br /> Any 3.INN <br /> Department Manager <br /> • <br /> TOTAL P.02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.