Laserfiche WebLink
❑ Pipes,ducts,wires,equipment and flues and chimneys through the interior air barrier are sealed. <br /> ❑ A sealed continuous interior air barrier is installed on the warm side of the building envelope at ceilings,walls,and floor rim joist <br /> areas'. <br /> ❑ Air barrier behind tub and shower is sealed and protected. <br /> ❑ Recessed light fixtures are sealed. <br /> Envelope Insulation: <br /> ❑ Basement insulation R-5 minimum. <br /> ❑ Wind wash barrier on wall separating house and garage is sealed. <br /> ❑ Loose fill insulation is prevented from entering the eaves. <br /> ❑ Insulation on skylight shafts and walls exposed in attics is supported on the unconditioned side. <br /> Attic Insulation: <br /> ❑ Attic access panel insulated to R-38 for ceiling panel and R-19 for wall panel. <br /> ❑ Attic card attached to framing near access opening. <br /> ❑ Notification of attic R-value and date of installation posted near building permit inspection card. <br /> This is a summary only.Other requirements may apply.See the Minnesota Energy Code.Questions?Call the Department of Public <br /> Service Information Center at 651-296-5175 or 1-800-657-3710. <br /> • <br /> • <br /> Proeschel Residence Page 3 of 3 <br />