Laserfiche WebLink
II <br /> New Construction Energy Code Compliance Certificate <br /> Per N1101.8 Building Certificate.A building certificate shall be posted in a permanently visible location inside the Date Certificate Posted <br /> building. The certificate shall be completed by the builder and shall list information and values of components O lad O n <br /> listed in Table N1101.8. 4/23/15 5 <br /> Mailing Address of the Dwelling or Dwelling Unit City a m e S <br /> Orono CONSTRUCTION <br /> Name of Residential Contractor MN License Number <br /> GORDON JAMES CONSTRUCTION BC531961 <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type:Check All That Apply X Passive(No Fan) <br /> w <br /> o o <br /> . . <br /> ORONO COPY -,-:„ . <br /> a <br /> T 0 Active(With fan and monometer or <br /> T other system monitoring device) <br /> o. <br /> o a 4 U d .00 c) <br /> d Fc CO g U -8 <br /> o y H o 0 w o <br /> Insulation Location •° z U 0 W <br /> � o � m � m 10 7:0.�- C 2 1 g G <br /> F .6 z i=. w wo wo a i _Other Please Describe Here <br /> Below Entire Slab ---- J( <br /> Foundation Wall w/Waterproofing R-10 X Exterior w/Waterproofing <br /> Perimeter of Slab on Grade(2"Rigid on Fnd wall) X <br /> Rim Joist(Foundation) 2 1/4"Thick X Type in location:interior exterior or integral <br /> Wall R-21 X <br /> Ceiling,flat(attic) R-50 X <br /> Ceiling,vaulted(attic) R-50 X _ <br /> Bay Windows or cantilevered areas R-38 X <br /> Bonus room over garage X <br /> Describe other insulated areas <br /> Windows 8 Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Average U-Factor(excludes skylights and one door)U: 0.30 Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): 0.32 21 R-value <br /> MECHANICAL SYSTEMS I Make-up Air Select a Type <br /> Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code <br /> Fuel Type Gas Electric Passive <br /> Manufacturer Lennox Lennox Powered <br /> Interlocked with exhaust device. <br /> Model EL296UHO9XV48C XC-048-230 Describe: <br /> Input in Capacity in Output in Other,describe: <br /> Rating or Size BTUS: 90,000 Gallons: Tons: 4 <br /> Heat Loss: 74,305 Heat Gain: 27503 Location of duct or system: <br /> Structure's Calculated <br /> AFUEor 41111111 SEER: 16 MECHANICAL ROOM <br /> HSPF% 96.00/0 <br /> Calculated 30,110 <br /> Efficiency cooling load: Cfm's <br /> • <br /> "round duct OR <br /> Mechanical Ventilation System "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace): NONE Not required per mech.code <br /> Select Type X Passive <br /> X Heat Recover Ventilator(HRV) Capacity in cfms: Low: 105 High: 197 Other,describe: <br /> Energy Recover Ventilator(ERV)Capacity in cfms: Low: High: Location of duct or system: <br /> Continuous exhausting fan(s)rated capacity in cfms: MECHANICAL ROOM <br /> Location of fan(s),describe: BATHROOMS 60 Cfm's <br /> Capacity continuous ventilation rate in cfms: 6 "round duct OR <br /> Total ventilation(intermittent+continuous)rate in clips: 200/105 "metal duct <br /> 'O.,....1-11..., 0/J.1 06E000 <br />