My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-00024 - new house
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
420 Lakeview Parkway - 06-117-23-32-0016
>
Permits/Inspections
>
2018-00024 - new house
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:26:53 PM
Creation date
4/13/2018 3:36:50 PM
Metadata
Fields
Template:
x Address Old
House Number
420
Street Name
Lakeview
Street Type
Parkway
Address
420 Lakeview Pkwy
Document Type
Permits/Inspections
PIN
0611723320016
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Site address 420 Lakeview Parkway Date 10/1/17 <br /> Contractor Sabre Heating And A/C Completed Josh G. <br /> Section A <br /> Ventilation Quantity <br /> (Determine quantity by using Table R403.5.2 or Equation 11-1) <br /> Square feet(Conditioned area including 5681 Total required ventilation 225 <br /> Basement—finished or unfinished) - <br /> Continuous ventilation <br /> 6 113 Number of bedrooms <br /> Directions-Determine the total and continuous ventilation rate by either using Table R403.5.2 or equation 11-1. <br /> The table and equation are below <br /> Table R403.5.2 <br /> Total and Continuous Ventilation Rates(in cfm) _ <br /> Number of Bedrooms - <br /> 1 2 3 4 5 6 <br /> Conditioned space(in Total/ Total/ Total/ Total/ Total/ Total/ <br /> sn,ft.) continuous continuous continuous continuous continuous continuous <br /> 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 <br /> 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 <br /> 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 <br /> 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 <br /> 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 <br /> 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 <br /> 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 <br /> • 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 <br /> 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 <br /> 5501-6000 150/75 165/83 180/90 195/98 :210/105 05/11D <br /> Equation 11-1 <br /> (0.02 x square feet of conditioned space)+[15 x(number of bedrooms+1)]=Total ventilation rate(cfm) <br /> Total ventilation-The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate <br /> average,for each one-hour period according to the above table or equation.For heat recovery ventilators(HRV)and energy <br /> recovery ventilators(ERV)the average hourly ventilation capacity must be determined in consideration of any reduction of <br /> exhaust or out outdoor air intake,or both,for defrost or other equipment cycling. <br /> Continuous ventilation-A minimum of 50 percent of the total ventilation rate,but not less than 40 cfm,shall be provided, <br /> on a continuous rate average for each one-hour period.The portion of the mechanical ventilation system intended to be <br /> continuous may have automatic cycling controls providing the average flow rate for each hour is met. <br />
The URL can be used to link to this page
Your browser does not support the video tag.