' Section E <br /> Make-up air <br /> 0 Passive (determined from calculations from Table 501.3.1) <br /> 0 Powered(determined from calculations fro Table 501.3.1) <br /> Q Interlocked with exhaust device(determined from calculation from Table 501.3.1) <br /> 0 Other,describe: <br /> Location Of duct or system ventilation make-up air: Determined from make-up air opening table <br /> Cfm Size and type(round,rectangular,flex or rigid) <br /> Directions -In order to determine the makeup air, Table 501.3.1 must be filled out(see below). For most new <br /> installations, column A will be appropriat , however, if atmospherically vented appliances or solid fuel appliances are <br /> installed, use the appropriate column. For existing dwellings,see IMC 501.3.3. Please note, if the makeup air quantity <br /> is negative, no additional makeup air will be re-quired for ventilation, if the value is positive refer to Table 501.3.2 and <br /> size the opening. Transfer the cfm, sizeof opening and type(round, rectangular, flex or rigid)to the last line of section D. <br /> The make-up air supply must be installed per IMC 501.3.2.3. <br /> Table 501.3.1 <br /> PROCEDURE TO DETERMIN MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS <br /> (Additional combustion air ill be required for combustion appliances,see KAIR method for calculations) <br /> One or m Itiple power One or multiple fan- One atmospherically vent Multiple atmospherically <br /> vent or di ct vent assisted appliances and gas or oil appliance or vented gas or oil appliances <br /> appliance or no power vent or direct one solid fuel appliance or solid fuel appliances <br /> combustiappliances vent appliances <br /> C lumn A Column B Column C Column D <br /> ' <br /> a)pressure factor(cfm/sf) 1115 0.09 0.06 0.03 <br /> b)conditioned floor area(sf) I6920 <br /> (including unfinished basements) I " <br /> Estimated House Infiltration(cfm): 623 <br /> [lax1b] <br /> 2.Exhaust Capacity <br /> a)continuous exhaust-only NA BALANCED <br /> ventilation system(cfm);(not <br /> applicable to balanced ventilation <br /> systems such as HRV) <br /> b)clothes dryer(cfm) 1135 135 135 135 <br /> c)80%of largest exhaust rating(cfm); <br /> Kitchen hood typically(not applicable 720 <br /> if recirculating system or if powered <br /> makeup air is electrically interlocked <br /> and match to exhaust) <br /> d)80%of next largest exhaust rating <br /> (cfm); bath fan typically(not Not 64 <br /> applicable if recirculating system or if <br /> powered makeup air is electrically Applicable <br /> interlocked and matched to exhaust) <br /> Total Exhaust Capacity(cfm); 919 <br /> [2a+2b+2c+2d] <br /> 3.Makeup Air Quantity(cfm) 919 <br /> a)total exhaust capacity(from above) <br /> b)estimated house infiltration(from 623 <br /> above) <br /> Makeup Air Quantity(cfm); �� <br /> [3a—3b](if value is negative,no <br /> makeup air is needed) i <br /> 4.For makeup Air Opening Sizing, <br /> refer to Table 501.4.2 Passive 10„Duct <br /> A. Use this column if there'are other than fan-assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances.(Power <br /> vent and direct vent appliances may be used.) <br /> B. Use this column if there is one fan-assisted appliance per venting system.(Appliances other than atmospherically vented appliances may be included.) <br /> C. Use this column if there is one atmospherically vented(other than fan-assisted)gas or oil appliance per venting system or one solid fuel appliance. <br /> D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or <br /> oil appliances and solid fuel appliances. <br /> 3 <br />