My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-01026 - new structure
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road South
>
0425 Old Crystal Bay Road South - 04-117-23-31-0001
>
Permits/Inspections
>
2017-01026 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:12:04 PM
Creation date
3/23/2018 12:48:34 PM
Metadata
Fields
Template:
x Address Old
Address
0425 Old Crystal Bay Rd S
Document Type
Permits/Inspections
PIN
0411723310001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section B <br /> Ventilation Method <br /> (Choose either balanor exhaust) <br /> ✓ lalanced,HRV(Heat Recovery Ventilator)or ERV(Energy la haust only(Continuous fan rating in cfrn) <br /> Recov-ery Ventilator)—dm of unit in low must not exceed <br /> continuous venti-lation rating by more than 100%. <br /> Low cfm: 175 High dm: 280 Contirjuous fan rating in dm(capacity must not exceed <br /> continuous ventilation rating by more than 100%) <br /> Directions -Choose the method of ventilation, balanced or exhaust only. Balanced ventilation systems are typically HRV or <br /> ERV's. Enter the low and high cfm amounts. Low cfm air flaw must be equal to or greater than the required continuous <br /> ventilation rate and less than 100%greater than the continupus rate. (For instance, if the low cfm is 40 cfm, the ventilation <br /> fan must not exceed 80 cfm.)Automatic controls may allow the use of a larger fan that is operated a percentage of each <br /> hour. <br /> 11 <br /> Section C <br /> Ventilation Fan <br /> Description Location Continuous Intermittent <br /> NA <br /> I <br /> Directions -The ventilation fan schedule should describe what the fan is for, the location, cfm, and whether it is used for <br /> continuous or intermittent ventilation. The fan that is chose(or continuous ventilation must be equal to or greater than the <br /> low cfm air rating and less than 100%greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the <br /> continuous ventilation fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a <br /> percentage of each hour. <br /> Section D <br /> Ventilatipn Controls <br /> Directions-Describe operation and control of the continuous and intermittent ventilation. There should be adequate detail for plan <br /> reviewers and inspectors to verify design and installation compliance. Related trades also need adequate detail for placement of controls <br /> and proper operation of the building ventilation. If exhaust fans are used for building ventilation,describe the operation and location of any <br /> controls, indicators and legends. If an ERV or HRV is to be installed,describe how it will be installed. If it will be connected and interfaced <br /> with the air handling equipment,please describe such connections as detailed in the manufactures'installation instructions. If the <br /> installation instructions require or recommend the equipment to be interlocked with the air handling equipment for proper operation, such <br /> interconnection shall be made and described. <br /> Honeywell Prestige IAQ thermostat to control ventilation per Ashrae. <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.