F4 <br />H <br />GENERAL NOTES <br />ELECTRICAL <br />SYMBOLS <br />NOMINAL <br />MOUNTING <br />A. MOUNT <br />EQUIPMENT AT NOMINAL MOUNTING HEIGHT INDICATED IN ELECTRICAL SYMBOL <br />SYMBOL <br />DESCRIPTI❑N HEIGHT <br />SCHEDULE <br />UNLESS NOTED OTHERWISE ON THE FLOOR PLANS OR <br />DETAILED IN <br />LIGHTING AND POWER <br />ARCHITECTURAL ELEVATIONS. DIMENSION SHOWN IS TO CENTER LINE OF BOX, <br />® LIGHT FIXTURE <br />** <br />B. SEE ARCHITECTURAL <br />INTERI❑R ELEVATIONS FOR EXACT LOCATION OF WALL MOUNTED <br />C_� <br />LIGHT FIXTURE <br />** <br />DEVICES AND LIGHT FIXTURES. <br />® <br />EXIT LIGHT <br />** <br />C. INSTALL <br />INSULATED GREEN GROUND CONDUCTOR WITH ALL BRANCH CIRCUIT AND <br />0 <br />LIGHT FIXTURE ON <br />** <br />FEEDER <br />CONDUCTORS, SIZED PER NEC 250-95, <br />EMERGENCY CIRCUIT <br />PART OF LIGHT FIXTURE <br />D. SEE ARCHITECTURAL <br />REFLECTED CEILING PLANS FOR FINAL L❑CATION <br />OF CEILING <br />❑N EMERGENCY CIRCUIT <br />MOUNTED <br />EQUIPMENT. <br />()9- <br />LIGHT TRACK <br />** <br />E. THREE <br />AND FOUR LAMP FLUORESCENT LUMINAIRES ARE TO BE <br />BI-LEVEL SWITCHED <br />'-� <br />POLE MOUNTED LIGHT <br />** <br />WITH OUTBOARD <br />LAMPS CONNECTED TO SWITCH %' AND INBOARD <br />LAMPS CONNECTED <br />FIXTURE <br />TO SWITCH <br />'b', TYPICAL UNLESS NOTED OTHERWISE. <br />419- <br />SINGLE POLE SWITCH <br />48' <br />F. IN GENERAL„ BRANCH CIRCUIT CONDUIT AND WIRE IS NOT SHOWN. <br />PROVIDE CONDUIT <br />-692 <br />2 POLE SWITCH <br />48' <br />AND WIRE <br />TO CONNECT DEVICES TO CIRCUITS SHOWN, WIRE <br />FILL AND CONDUCTOR <br />4,43 <br />3 WAY SWITCH <br />48' <br />SIZE SHALL BE AS SPECIFIED. <br />-644 <br />4 WAY SWITCH <br />48' <br />-69K <br />KEY OPERATED SWITCH <br />48' <br />_164M <br />OD <br />MOMENTARY CONTACT <br />SWITCH <br />DIMMER/DIMMER CONTROL <br />48' <br />48' <br />DRAWING INDEX <br />E001 <br />ELECTRICAL SYMBOLS, SITE PLAN <br />-64P <br />SWITCH WITH PILOT LIGH148' <br />� <br />SEPERATE PILOT LIGHT <br />a8• <br />E201 <br />LIGHTING FLOOR PLAN <br />Q <br />OCCUPANCY SENSOR <br />** <br />E301 <br />POWER AND SIGNAL FLOOR PLAN <br />QT <br />TIME CONTROL <br />** <br />E401 <br />SCHEDULES ONE LINE DIAGRAM <br />© <br />PHOT❑CONTROL <br />** <br />-e <br />SINGLE 125V RECEPTACLEI8' <br />=0 <br />DUPLEX 125V RECEPTACLEI8' <br />-9 <br />SPECIAL PURPOSE <br />** <br />RECEPTACLE <br />DOUBLE DUPLEX <br />18' <br />RECEPTACLE <br />EMERGENCY DUPLEX <br />18' <br />RECEPTACLE < <br />EMERGENCY DOUBLE <br />18' <br />DUPLEX RECEPTACLE <br />SWITCHED OR SPLIT <br />18' <br />WIRED RECEPTACLE <br />JUNCTION BOX <br />-- <br />Q <br />FLOOR BOX <br />-- <br />© <br />CLOCK <br />80' <br />PUSHBUTTON <br />48' <br />MUSHROOM TYPE <br />48' <br />PUSHBUTTON <br />—Pl— <br />SURFACE MOUNTED RACEWAY <br />** <br />—Rl— <br />UNDERFLOOR RACEWAY <br />-- <br />SYSTEM <br />SYMBOL EXPLANATION <br />COMMUNICATION <br />® <br />VOICE\DATA OUTLET <br />18' <br />® <br />PAY TELEPHONE <br />48' <br />DEVICES SHOWN IN THIS MANNER INDICATE THE GANGING <br />P <br />49 OR b9 <br />TOGETHER OF THE DEVICES UNDER COMMON COVER PLATE. <br />INTERCOM <br />18' <br />UPPER CASE LETTER INDICATES LIGHT FIXTURE TYPE. LOWER CASE <br />a <br />COMPUTER SYSTEM <br />18' <br />boA <br />23 <br />INDICATES CONTROL, NUMBER INDICATES CIRCUIT CONNECTION. <br />OUTLET <br />(SEE LIGHT FIXTURE SCHEDULE) <br />aTVwinTELEVISION <br />OUTLET <br />* <br />ARROWS CONNECTED TO A DEVICE INDICATE AIMING <br />DIRECTION. ARROWS <br />AUDI❑ <br />NEAR ALL EXIT SIGNS IDENTIFY DIRECTION OF ARROW ON FACE PLATE. <br />_- <br />SHADED PDRTWN OF EXIT SIGN INDICATES FACE(S) <br />TO BE ILLUMINATED, <br />SPEAKER <br />VOLUME CONTROL <br />48' <br />�D <br />SPECIAL RECEPTACLES. THE TYPE IS SHOWN WITH <br />LETTER, SEE THE SPECIAL RECEPTACLE SCHEDULE <br />AN UPPER CASE <br />FOR THE <br />® <br />MICROPHONE OUTLET <br />18' <br />DESCRIPTION. <br />AUXILLARY OUTLET <br />18' <br />�2 <br />THE CIRCUIT DESIGNATION IS SHOWN BY NUMBER FOR <br />ADJACENT EQUIPMENT. <br />PROJECTOR CONTROL <br />18' <br />EXAMPLEi DUPLEX OUTLET ON CIRCUIT NUMBER 2. <br />OUTLET <br />"D600 <br />WALL BOX DIMMER WITH SIZE AS INDICATED AT DEVICE. EXAMPLE] <br />POWER DISTRIBUTION <br />600 WATT WALL BOX DIMMER. <br />/Cy <br />MOTOR <br />-- <br />THE SYMBOL INDICATES TYPE OF DEVICE TO BE INSTALLED IN THE <br />SAFETY DISCONNECT <br />** <br />FLOOR BOX, EXAMPLE, A FLOOR BOX WITH A DUPLEX <br />RECEPTACLE <br />SWITCH <br />AND A TELEPHONE OUTLET. <br />® <br />MAGNETIC STARTER <br />** <br />SYMBOL WITH EQUIPMENT IDENTIFICATION. SEE MOTOR OR <br />COMBINATION STARTER <br />** <br />,�EF-1 <br />EQUIPMENT SCHEDULE FOR COMPLETE ELECTRICAL INFORMATION. <br />MANUAL MOTOR STARTER <br />** <br />EXAMPLEt EXHAUST FAN #1. <br />® <br />RELAY OR CONTACTOR <br />A <br />UPPER CASE LETTER INDICATES SPEAKER TYPE. <br />® <br />CONTROL STATION <br />-- <br />SEE SPECIFICATIONS. <br />® <br />TRANSFORMER <br />-- <br />-� <br />LIGHT FIXTURES OR DEVICES SHOWN WITH STEM <br />ARE TO BE WALL MOUNTED <br />o <br />POWER OR DISTRIBUTI❑N <br />** <br />PANEL <br />PLAN KEYED NOTE. SEE KEYED NOTE SCHEDULE ON <br />THAT SHEET. ARROW <br />PANELBOARD <br />** <br />1 <br />POINTS TO THE ITEM TO WHICH THE NOTE APPLIES. <br />SECURITY <br />® <br />CODE CARD READER <br />40' <br />3/4'C #8 <br />INDIVIDUAL HOME RUN TO BRANCH CIRCUIT PANELBOARD. PANELBOARD ANDMO <br />MONIT❑RING DEVICE <br />** <br />` <br />CIRCUIT DESIGNATION ARE PLACED ADJACENT TO HOMERUN ARROW, MULTI-POLE <br />L <br />Q <br />DOOR LOCK/STRIKE <br />77- <br />L2A CIRCUIT BREAKERS ARE INDICATED BY THE FIRST POLE <br />NUMBER FOLLOWED <br />BY CAMPS / NUMBER OF POLES). EXAMPLE] HOMERUN TO PANEL L2A. <br />oa <br />TELEVISION CAMERA <br />** <br />L315 <br />UNDESIGNATED SLASH MARKS INDICATE #12 C❑NDUCTORSI NO SLASH MARKS <br />OUTLET <br />INDICATE 2 #12 CONDUCTORS. CONDUCTOR SIZES INDICATED ADJACENT TO <br />SLASH MARKS SHALL APPLY TO ENTIRE CIRCUITS. <br />FIRE ALARM <br />® <br />SMOKE DETECTOR <br />-- <br />-P1— <br />'Pl' OR 'Rl' INDICATES RACEWAY TYPE, REFER <br />TO SPECIFICATIONS <br />DUCT SMOKE DETECTOR <br />-- <br />OR <br />o—Rl— <br />® <br />SPRINKLER FLOW SWITCH -- <br />® <br />GATE VALVE SWITCH <br />-- <br />r--{� <br />'m' or 's' INSIDE LIGHT FIXTURE INDICATES FIXTURE IS PART OF <br />® <br />MAGNETIC DOOR HOLDER <br />J <br />MASTER/SATELLITE COMBINATION. DASHED LINE INDICATES FACTORY <br />® <br />DAMPER OPERATOR <br />INTERCONNECT. <br />® <br />FIRE ALARM MANUAL <br />48' <br />STATION <br />® <br />FIRE ALARM AUDIO- <br />80' <br />VISUAL UNIT <br />ELECTRICAL ABBREVIATI❑NS <br />® <br />FYRE ALARM VISUAL UNIT 80' <br />�{ <br />FIRE ALARM CHIME <br />80• <br />LFjQ <br />FIRE ALARM AUDIO UNIT <br />80' <br />ABBREV. <br />DESCRIPTION <br />[ <br />FIRE FIGHTER PHONE JAC148' <br />A,AMP <br />AMPERE MCC <br />MOTOR CONTROL CENTER <br />® <br />HEAT DETECTOR <br />-' <br />A/C <br />AIR CONDITIONING MIN <br />MINIMUM <br />HEAT DETECTOR HIGH <br />-- <br />AFF <br />ABOVE FINISH FLOOR MISC <br />MISCELLANEOUS <br />TEMPERATURE <br />AIC <br />AMPERE INTERRUPTING MLO <br />MAIN LUGS ONLY <br />AL <br />CAPACITY MHS <br />ALUMINUM MOA <br />MANUAL MOTOR STARTER <br />MULTI-OUTLET ASSEMBLY <br />CONDUIT AND WIRING <br />APPROX <br />APPROXIMATELY MTR <br />MOTOR <br />CONDUIT CONCEALED IN <br />-- <br />ARCH <br />ARCHITECT, ARCHITECTURAL <br />WALL OR OVERHEAD <br />ATS <br />AUX <br />A�JTOMATIC TRANSFER SWITCH N/C <br />A X1UlA1ty NEC <br />NORMALLY CLOSED <br />NAiIUNAL ELLL;IKICAL LUTA_ <br />/V <br />iDivLuii iurvEtALEy iri <br />-- <br />AV <br />AUDIO VISUAL NEMA <br />NATI❑NAL ELECTRICAL <br />OR BELOW FLOOR <br />CTURER'S <br />CONDUIT INSTALLED <br />-- <br />BLDG <br />BUILDING <br />ASS❑CIA I® <br />EXPOSED <br />NFSS <br />NON-FUSED SAFETY <br />C <br />CONDUIT <br />SWITCH <br />—• <br />CONDUIT VERTICAL <br />-- <br />CB <br />CIRCUIT BREAKER NIC <br />NOT IN CONTRACT <br />TRANSITION <br />CCTV <br />CLOSED CIRCUIT TELEVISION N/O <br />NORMALLY OPEN <br />CLG <br />CEILING NTS <br />NOT T❑ SCALE <br />�-y <br />CONDUIT STUBBED OUT <br />-- <br />CONN <br />CONNECTION <br />CONDUIT SEAL <br />-- <br />CONT <br />CONTINUOUS OR OL <br />CONTINUATION <br />OVERLOADS <br />/\ <br />EXISTING-C❑NDUIT <br />-- <br />CRT <br />CATHODE-RAY TUBE P <br />POLE/ <br />EX <br />EXISTING CONDUIT <br />-- <br />C/T <br />CURRENT TRANSFORMER PA <br />PUBLIC ADDRESS <br />INTERCEPTED <br />CEN <br />CENTER PE <br />PNEUMATIC ELECTRIC <br />CU <br />COPPER PF <br />POWER FACTOR <br />, UTA <br />UNDERGROUND TELEPHONE -- <br />DISC <br />PH <br />DISCONNECT PNL <br />PHASE <br />PANEL <br />/ L----, <br />LOW VOLTAGE CABLE <br />-- <br />DIST <br />DISTRIBUTION PP <br />POWER POLE <br />1--k. <br />INDIVIDUAL BRANCH <br />-- <br />DN <br />DOWN PR <br />PAIR' <br />CIRCUIT HOMERUN <br />DWG <br />DRAWING PRI <br />PRIMARY <br />PROD <br />PROJECTION <br />MISCELLANEOUS <br />ECB <br />ENCLOSED CIRCUIT BREAKER PRV <br />P/T <br />POWER ROOF VENTLATOR <br />PO T E:11ITIAL TRANSFORMER <br />BUZZER <br />vv' <br />ELL <br />ELEC <br />ELECTRIC(AL) <br />,_ _ECTRIC( ':= r; ; ? 1 PT e moi; <br />,,. <br />P^i I JTNYL CH�CRIL <br />i <br />EP <br />�I <br />Et.ECTf''IC PiJEUNATIC READ <br />REQi ED <br />i LA <br />GtiiHc <br />30' <br />EQUIP <br />EQUIPMENT <br />BELL <br />BO° <br />EWC <br />ELECT RTC WATER COOLER <br />SJQ <br />SOLID <br />EXST <br />EXH <br />EXISTING <br />EXHAUST <br />SPECIFICATION <br />,�;, <br />CROSS HATCHING OF <br />DASHED SYMBOL <br />-- <br />EXP <br />SPEC <br />EXPLOSION PROOF SPKR <br />SPEAKER <br />F "< <br />INDICATES REMOVED <br />F <br />FUSE SP <br />STD <br />SPARE <br />STANDARD <br />DASHED SYMBOL <br />-- <br />FA <br />FIRE ALARM SW <br />SWITCH <br />INDICATES EXISTING <br />FLR <br />FLOOR SWBD <br />SWITCHBOARD <br />EQUIPMENT AS NOTED <br />** <br />SWGR <br />SWITCHGEAR <br />GALV <br />GALVANIZED SYM <br />SYMMETRICAL <br />GFI <br />GROUND FAULT CIRCUIT SYS <br />SYSTEM <br />KEYED NOTE <br />'- <br />GNP <br />INTERRUPTER TEL <br />GROUND <br />TELEPHONE <br />GYP <br />GYPSUM TERM <br />TERMINAL <br />XFMR <br />TRANSFORMER <br />HOA <br />HAND-OFF-AUTOMATIC SWITCH TV <br />TELEVISION <br />H❑RIZ <br />HORIZONTAL TYP <br />TYPICAL <br />HP <br />HGT <br />HORSEPOWER <br />HEIGHT UE <br />UNDERGROUND ELECTRICAL <br />HV <br />HIGH VOLTAGE UG <br />UNDERGROUNDUH <br />UNIT HEATER <br />- <br />JB <br />JUNCTION BOX UT <br />UNDERGROUND TELEPHONE <br />KV <br />KILOVOLT V <br />VOLT <br />KVA <br />KILOVOLT-AMPERE VA <br />VOLT AMPERES <br />KVAR <br />KILOVOLT-AMPERE REACTIVE VDT <br />VIDE❑ DISPLAY TERMINAL <br />KW <br />KILOWATT VERT <br />VERTICAL <br />KWH <br />KILOWATT HOUR VFD <br />VARIABLE FREQUENCY DRIVE <br />VOL <br />VOLUME <br />LV <br />LOW VOLTAGE W <br />WATT <br />** - SEE DRAWING SPECIFICATION <br />OR LIGHTING <br />W/ <br />W/O <br />WITH <br />WITHOUT <br />FIXTURE SCHEDULE FOR MOUNTING HEIGHT <br />WP <br />WEATHERPROOF <br />F4 <br />H <br />
The URL can be used to link to this page
Your browser does not support the video tag.