Laserfiche WebLink
PC.The PC's IP address must be set to the default range of In addition to Contact ID alarm communication, the IPDACT- <br /> the IPDACT-2/2UD such as 192.168.0.XX. 2UD version 6.0 supports upload and download to the panel <br /> 3. Windows-based configuration software (shipped with IP from anywhere on the Internet.This communication uses stan- <br /> Communicator version 6.0 or higher). Version 6.0 permits dard modem control signals wrapped up in TCP/IP packets. <br /> use of either Ethernet Crossover cable or Serial Cable. Standard programming software such as PS-Tools are used <br /> on the remote programming PC. A separate application <br /> ORDERING OPTIONS (UDPORT.exe) is started on the programming PC. This soft- <br /> IPDACT-2: IP Communicator. Includes configuration software, ware contains settings that include central station receiver IP <br /> manuals, and prepared 30"telephone cable for connection to address, port number, upload/download username and pass- <br /> panel's DACT Telco ports. word(supplied by central station).UDPORT is set to a specific <br /> IPDACT-2UD: IP Communicator with upload/download capa- communication port that will be used by the programming soft- <br /> bility (2UD modem daughter board). Includes configuration ware.The PK-PLUS program is also set to this same commu- <br /> software,manuals,and prepared 30"telephone cable for con- nicationport. The programming software must contain a <br /> to panel's DACT telco ports. subscriber number that matches the desired remote IPDACT- <br /> nection2UD card's subscriber number set at the central station. PK- <br /> 2UD: Optional modem daughter board for upgrading an PLUS "dials" the remote via standard ATDT modem corn- <br /> IPDACT 2 to an IPDACT-2UD. mands.The IPDACT-2UD v.32 modem daughter card sees the <br /> IPBRKT:Mounting bracket kit consisting of screws and battery modem commands via TCP/IP and provides a RING to the <br /> shield with standoffs. Required for mounting in lower enclo- panel. The modem on the panel handshakes with the local <br /> sure section of NFW-50, NFW2-100, SFP-5UD, and SFP- IPDACT-2UD modem and communications begin.While com- <br /> 10UD. Required for use with 411 and HP3000LX in competi- munications are limited to the panel's baud rate, the advan- <br /> tive fire panels. tage is that all communications from the remote site <br /> programming PC all the way to the remote panel are fully digi- <br /> IPENC: External mounting enclosure consisting of mounting tal and are not subject to drop outs due to phone line noise. <br /> bracket IPBRKT, and screws. Enclosure must be "close-nip- <br /> ple"to a panel.(Red;order IPENC-B for black.) Temperature and Humidity Ranges <br /> IPSPLT: Y adaptor option to allow connection of both panel <br /> dialer outputs to one cable input to IPDACT-2/2UD. This system meets NFPA requirements for operation at 0 - <br /> 49°C/32-120°F and at a relative humidity up to 93%±2%RH <br /> ALMSC-119:Serial programming cable. (non-condensing) at 32°C ± 2°C (90°F ± 3°F) However, the <br /> HP3000LX: Honeywell Power Products UL 1481-listed auxil- useful life of the electronic components may be adversely <br /> iary power supply. Enclosure must be"close-nipple"to a panel affected by extreme temperature ranges and humidity.There- <br /> via conduit. Requires IPBRKT purchased separately. fore it is recommended that this system and its peripherals be <br /> installed in an environment with a normal room temperature of <br /> IPCHSKIT: IP Communicator Chassis Mounting Kit. For 15-27°C/60-80°F. <br /> mounting an IPDACT-2/2UD onto a CHS-4/N, CHS-4L, CHS- <br /> M3,or NFS2-640 Chassis. Agency Listings and Approvals <br /> System Architecture/Operating Theory The listings and approvals below apply to the IP Communica- <br /> tor. In some cases certain modules may not be listed by cer- <br /> The Fire Watch IP Communicators and an Ethernet connection tain approval agencies,or listings may be in process. Consult <br /> simply replace the telephone lines as the primary communica- factory for latest listing status. <br /> tions path to the central station. It connects to customer sup- <br /> plied network equipment with a gateway to the Internet. The • UL:S2424,S624 <br /> communicators provide supervised telephone line voltage to • CSFM:7300-0075:223. <br /> both panel DACT ports. Upon network communication loss, <br /> telephone line voltage is dropped to the panel and panel <br /> reports communication loss trouble.The communicators moni- <br /> tor the connectivity to both the primary and secondary receiver <br /> at the central station. Upon failure of a central station receiver <br /> the backup automatically and instantly assumes the primary <br /> role.The communicator supervises the connection to the cen- <br /> tral station at a minimum of once every 90 seconds. <br /> For a Fire or Trouble event, The Fire Alarm Panel will send <br /> Contact ID alarm event information from its DACT port. The <br /> communicator will sense the off-hook status of the panel and <br /> accept all data. The IP Communicator will then immediately <br /> packetize the Contact ID information into UDP protocol and <br /> encrypt it with 512 bits of AES encryption and send it to the <br /> central station. The central station receiver will decrypt and FireWatchTM is a trademark and Notifier® is a registered trademark of <br /> unpacketize the Contact ID information and present it to the Honeywell International Inc.HyperTerminalTM is a trademark of Hilgrave Inc. <br /> central station automation software. Upon operator acknowl- Microsoft® is a registered trademark of the Microsoft Corporation. <br /> edgement the kiss-off signal will be sent back to the panel. VisorALARM®is a registered trademark of the Teldat Corporation. <br /> ©2014 by Honeywell International Inc.All rights reserved.Unauthorized use <br /> of this document is strictly prohibited. <br /> ISO 9001 This document is not intended to be used for installation purposes. <br /> We try to keep our product information up-to-date and accurate. <br /> C E R T F E O We cannot cover all specific applications or anticipate all requirements. <br /> ENCINEMINC 8 MURMURING All specifications are subject to change without notice. <br /> QUALITY SYSTEMS <br /> For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. <br /> www.notifier.com <br /> Page 4 of 4—DN-60408:D3•10/15/2014 <br />