Laserfiche WebLink
NOTE: The 411 UD application for monitoring Alarm, Trouble and <br /> Supervisory relays of a competitive FACP requires mounting both <br /> ID the 411 UD and IPDACT-2UD inside the HP3000LX. <br /> 4. When more power is required,the IP Communicator can <br /> be mounted inside the HP3000LX power supply. The <br /> power supply should be connected to the fire alarm panel <br /> ® ' with a short piece of conduit. <br /> 0 • Fire Alarm <br /> Control Panel 1 <br /> I ® 0(FACP) i <br /> IP <br /> FACP backbox,® ' ® Circuit Board Communicator <br /> standoffs ® C <br /> ® . .- 1111 <br /> IPDACT module 4* Ow , o Primary <br /> �� , - a. I <br /> IPBRKT bracket ►o i Line i ti o <br /> ° I �� 0 0] <br /> . 0 I polycarbonate cover I HP3000LX <br /> with label Power Supply <br /> standoff 0 tandoff Metal conduit <br /> Mounting in the Control Panel Enclosure Mounting in the HP3000LX Power Supply <br /> 2. The IP Communicator can be mounted in a CAB-3/4 <br /> Series Cabinet using the IP Communicator Chassis Mount- NOTE: Refer to the IP Communicator Series Installation Docu- <br /> ing Kit P/N IPCHSKIT.The IPCHSKIT mounts onto a CHS- ment PN 53109 for additional installation information. <br /> 4/N,CHS-4L,CHS-M3,or NFS2-640 Chassis.If the system PROGRAMMING OPTIONS <br /> configuration does not support the installation of the <br /> IPCHSKIT, use the IPENC enclosure. 1. Console terminal using the HyperTerminal software pro- <br /> 3. The IP Communicator can be mounted inside the small gram found on all Microsoft operating systems. Requires <br /> add-on IPENC enclosure. This is typically used with previ- serial programming cable PN ALMSC-119. <br /> ous panels that did not use the common enclosure.This will 2. Local or remote Telnet session via Ethernet connection. <br /> be connected to the fire alarm panel with a short piece of Requires either switch/hub connection or Ethernet cross- <br /> conduit. over cable from laptop to Ethernet Port and programming <br /> HP3000LX <br /> U `_•MI AC Power <br /> X111Imo+24 VDC <br /> .'VDC <br /> +Battery/ !pi@-BatteryTo Alarm,Trouble, AC FailConw6 .li2.2Kb <br /> Supervisory FACE" 1111411.11... <br /> ;��'��� ELR <br /> Output Relays man alf; Illi •� 1 K <br /> on FACP 1111111 ELR <br /> (2.2KLI ELRs at FACP) ' j TG•1-.•'I F -• I� <br /> iitl. i ' { = a ' IPDA T <br /> Communicator Fault ll= ••• • ; I c i : <br /> to monitor module I Pili' I I ' p1wt <br /> i i , s i-' �al; To AP <br /> on FACP SLC Loop Iiiq rop i <br /> or in-line of ii�s € I { r _ Lh <br /> NAC on FACP ;.Eli .F ' .114•1131 a INPUT <br /> I i e 4 <br /> �; fl DC a "G24 VDC <br /> 64 isi <br /> i <br /> ® 'g <br /> 1 ' <br /> I 11111111111110A <br /> MINIM& <br /> Connecting the IPDACT,411 UD, and HP3000LX <br /> DN-60408:D3•10/15/2014—Page 3 of 4 <br />