My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-01498 - fire systems
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0800 Old Crystal Bay Road North - 28-118-23-43-0010
>
Permits/Inspections
>
2015-01498 - fire systems
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:48 PM
Creation date
3/14/2018 3:15:00 PM
Metadata
Fields
Template:
x Address Old
House Number
800
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
800 Old Crystal Bay Road North
Document Type
Permits/Inspections
PIN
2811823430010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TFP161 <br /> Page 2 of 6 <br /> Operation DEFLECTOR <br /> 1 - Frame <br /> The glass bulb contains a fluid which 2 - Button HAT 5 <br /> 4'�.G�isY.r6% <br /> expands when exposed to heat.When 3 -Sealing _ .' <br /> the rated temperature is reached, the Assembly <br /> fluid expands sufficiently to shatter the 4 - Bulb i�� ��,� <br /> glass bulb,allowing the sprinkler to ac- 5 - Compression <br /> tivate and water to flow. Screw <br /> 6 - Deflector* 6* 4 2 3 1 <br /> Design <br /> 9/16' WRENCH <br /> ** <br /> Criteria (14,3 mm) FLATS NPT <br /> The TYCO Series TY-B, 5.6 K-factor, �I / <br /> Horizontal and Vertical Sidewall Sprin- `r .-�7 *HAN <br /> klers are intended for fire protection -1/O\�- / 1/ <br /> systems designed in accordance with <br /> the standard installation rules recog- ��+ <br /> nized by the applicable Listing or Ap- • <br /> prove!agency(for example,UL Listing 1-13/16• 7/16° <br /> is based on the requirements of NFPA - (46,0 mm) (11,1 mm) <br /> 13, and FM Approval is based on the NOMINAL <br /> requirements of the FM Loss Preven- CENTERLINE MAKE-IN <br /> tion Data Sheets). Only the Style 10 OF SPRINKLER <br /> WATERWAY <br /> Recessed Escutcheon, as applicable, 1-1/2" <br /> is to be used for recessed horizontal x(38,1 mm)y <br /> installations. *Temperature rating <br /> is indicated on - 2-3/16' - <br /> Installation Deflector. (55,6 mm) <br /> ESCUTCHEON <br /> The TYCO Series TY-B, 5.6 K-factor, ** Pipe thread I STYLE 10 — I PLATE SEATING <br /> Horizontal and Vertical Sidewall Sprin- connections per RECESSED SURFACE <br /> klers must be installed in accordance ISO 7-1 can be ESCUTCHEON <br /> with this section. provided on <br /> special request. <br /> General Instructions ���1� <br /> Do not install any bulb type sprinkler 2-7/8'DIA. II►�__ <br /> if the bulb is cracked or there is a loss (73,0 mm) �,, I IIIIIIIIII I <br /> of liquid from the bulb.With the sprn- 3 •� <br /> 1 1 <br /> kler held horizontally,a small air bubble E <br /> should be present.The diameter of the <br /> air bubble is approximately 1/16 inch <br /> (1,6 mm)for the 135°F(57°C)to 3/32 <br /> inch(2,4 mm)for the 360°F(182°C)tem- <br /> perature ratings. FIGURE 1 <br /> A leak-tight 1/2 inch NPT sprinkler joint SERIES TY-B HORIZONTAL SIDEWALL(TY3351)SPRINKLER <br /> should be obtained by applying a min- 5.6 K-FACTOR STANDARD RESPONSE <br /> imum-to-maximum torque of 7 to 14 <br /> ft.-lbs. (9,5 to 19,0 Nm). Higher levels ceiling.The word"TOP"on the Deflec- Vertical Sidewall Sprinkler <br /> of torque may distort the sprinkler inlet tor is to face towards the ceiling. Installation <br /> and cause leakage or impairment of the The Series TY-13 Vertical Sidewall Sprin- <br /> sprinkler. Step A. After installing the Style 10 klers must be installed in accordance <br /> Do not attempt to make-up for insuf- Mounting Plate over the sprinkler with the following instructions. <br /> ficient adjustment in the escutcheon threads,hand-tighten the sprinkler into <br /> the sprinkler fitting. Install vertical sidewall sprinklers in the <br /> plate by under-or over-tightening the <br /> sprinkler. Readjust the position of the Step B.Tighten the sprinkler into the pendent or upright position with the ar- <br /> sprinkler fitting to suit. sprinkler fitting using only the W-Type 7 row on the Deflector pointing away from <br /> Recessed Sprinkler Wrench(Ref.Figure the wall. <br /> Horizontal Sidewall Sprinkler 5).Apply the W-Type 7 Recessed Sprin- Step 1.With pipe thread sealant applied <br /> Installation kler Wrench to the sprinkler wrench flats to the pipe threads, hand-tighten the <br /> The TYCO Series TY-B Recessed Hori- (Ref.Figure 1). sprinkler into the sprinkler fitting. <br /> zontal Sidewall Sprinklers must be in- <br /> stalled in accordance with the following Step C.After the ceiling is installed or Step 2. Tighten the sprinkler into the <br /> instructions. the finish coat is applied, slide on the sprinkler fitting using only the W-Type <br /> Install recessed horizontal sidewall Style 10 Closure over the Series TY-B 6 Sprinkler Wrench(Ref.Figure 4). For <br /> Sprinkler and push the Closure over the wax-coated sprinklers, use an 8 or 10 <br /> sprinklers in the horizontal position with Mounting Plate until its flange comes in inch adjustable Crescent wrench.Apply <br /> the centerline of waterway perpendicu- contact with the ceiling. the W-Type 6 Sprinkler Wrench or the <br /> lar to the back wall and parallel to the Crescent wrench,as applicable,to the <br /> wrench flats(Ref.Figure 2). <br />
The URL can be used to link to this page
Your browser does not support the video tag.