My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-01498 - fire systems
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0800 Old Crystal Bay Road North - 28-118-23-43-0010
>
Permits/Inspections
>
2015-01498 - fire systems
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:48 PM
Creation date
3/14/2018 3:15:00 PM
Metadata
Fields
Template:
x Address Old
House Number
800
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
800 Old Crystal Bay Road North
Document Type
Permits/Inspections
PIN
2811823430010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CICOWorldwide <br /> Fire Protection Contacts www.tyco-fire.com <br /> Products <br /> Series TY-B - 5.6 K-factor <br /> Horizontal and Vertical Sidewall Sprinklers <br /> Standard Response, Standard Coverage <br /> General plicable approval agencies, the test- I <br /> ing is not representative of all possible <br /> Description corrosive atmospheres.Consequently, <br /> it is recommended that the end user <br /> The TYCO Series TY-B, 5.6 K-factor, be consulted with respect to the suit- <br /> Horizontal and Vertical Sidewall Sprin- ability of these coatings for any given ./5- """ <br /> corrosive environment. The effects of1 <br /> klers described in this technical data ". . r <br /> sheet are standard response,standard ambient temperature,concentration of I �� <br /> coverage decorative 5 mm glass bulb chemicals, and gas/chemical velocity, ', <br /> type spray sprinklers designed for use should be considered, as a minimum, <br /> in light and ordinary hazard,commercial along with the corrosive nature of the , <br /> occupancies such as banks,hotels,and <br /> chemical to which the sprinklers will be <br /> shopping malls. exposed. <br /> They are designed for installation along NOTICE <br /> a wall or the side of a beam and just The Series TY-B Sprinklers described <br /> beneath a smooth ceiling. Sidewall herein must be installed and maintained <br /> sprinklers are commonly used insteadin compliance with this document, as <br /> of pendent or upright sprinklers due to well as with the applicable standards of <br /> aesthetics or building construction con- the National Fire Protection Association, ,... <br /> siderations, where piping across the in addition to the standards of any oth- r, <br /> ceiling is not desirable. er authorities having jurisdiction.Failure <br /> The recessed version of the Series TY-B to do so may impair the performance of <br /> Horizontal Sidewall Sprinkler is intend- these devices. •'. <br /> ed for use in areas with a finished wall. The owner is responsible for maintaining <br /> It uses a two-piece Style 10 Recessed their fire protection system and devices <br /> Escutcheon.The Recessed Escutcheon in proper operating condition. Contact '.' <br /> provides 1/2 inch(12,7 mm)of recessed the installing contractor or product man- _ <br /> adjustment or up to 3/4 inch(19,1 mm) ufacturer with any questions. <br /> of total adjustment from the flush side- -- <br /> wall position.The adjustment provided <br /> by the Recessed Escutcheon reduces Sprinkler Discharge Coefficient <br /> the accuracy to which the fixed pipe K=5.6 gpm/psif/2(80,6 Ipm/barti2) <br /> nipples to the sprinklers must be cut. Identification <br /> s, where Temperature Ratings <br /> Corrosion resistant coatings, Numbers Refer to Table A <br /> applicable, are utilized to extend <br /> the life of copper alloy sprinklers TY3351 —Horizontal Sidewall Finishes <br /> beyond that which would otherwise be TY3451 —Vertical Sidewall Sprinkler:Refer to Table C <br /> obtained when exposed to corrosive Recessed Escutcheon:Signal or Pure <br /> atmospheres. Although corrosion re- White,Jet Black,Chrome Plated,or <br /> sistant coated sprinklers have passed Technical Natural Brass <br /> the standard corrosion tests of the ap- <br /> Data Physical Characteristics <br /> Frame Bronze <br /> Approvals Button Brass/Copper <br /> IMPORTANT UL and C-UL Listed Sealing Assembly..Beryllium Nickel w/TEFLON <br /> Bs refer to Technical Data FMCompression <br /> Glass <br /> Always Approved Compression Screw Bronze <br /> Sheet TFP700 for the "INSTALLER LPCB Certified HSW Deflector Bronze <br /> WARNING"that provides cautions NYC Approved VSW Deflector Copper <br /> with respect to handling and instal (Refer to Table A for complete approval <br /> lation of sprinkler systems and com information, including corrosion-resis- <br /> ponents. Improper handling and in tant status.) <br /> stallation can permanently damage <br /> a sprinkler system or its compo- Maximum Working Pressure <br /> nents and cause the sprinkler to fail Refer to Table B <br /> to operate in a fire situation or cause <br /> it to operate prematurely. <br /> Page 1 of 6 APRIL 2015 TFP161 <br />
The URL can be used to link to this page
Your browser does not support the video tag.