/ a <br /> Crystal Bay Business Center II, Service Connections <br /> Sewer and/or Water Service Connection <br /> Plan No. 087547 <br /> Page 2 <br /> August 5, 2008 <br /> 5. Materials used for the subsoil (draintile)drains must comply with Minnesota Rules,part 4715.0620. No <br /> quality standard for this material is provided on the submitted plans. <br /> 6. Disinfection of the potable water system must include the following(see Minnesota Rules,part 4715.2250): <br /> a. The pipe system must be flushed with clean,potable water until no dirty water appears at the points of <br /> outlet; <br /> b. The system must then be filled with a water chlorine solution containing at least 50 parts per million of <br /> chlorine and allowed to stand for 24 hours; or a solution containing at least 200 parts per million of <br /> chlorine and allowed to stand for three hours; and <br /> c. Following the allowed standing time the system must be flushed with clean potable water until no <br /> chlorine remains. <br /> 7. The plumbing system shall be tested in accordance with Minnesota Rules,part 4715.2820. This includes <br /> all portions of the storm sewer located within 10 feet horizontally of the building or water service piping. <br /> NOTE(S): <br /> 1. This approval is for the site utilities only. Plans and specifications for the interior portion of the plumbing <br /> system have been reviewed under Plan No. 087584. <br /> 2. As noted in the July 14,2008, letter from Evelyn Turner,City Planner for Orono,the city engineer has <br /> reviewed and approved the civil plans for the above mentioned project. Once the sewer,water,and storm <br /> drain have been constructed in a manner satisfactory to the City,the owner will grant the City utility <br /> easements. The City will then accept the improvements. Turner's August 5,2008,email to our office <br /> clarified that the City will own and maintain the sanitary sewer and water mains within the easements. The <br /> City will also own the storm sewer mains within the easements and will maintain them except for the four <br /> manholes that are part of the sediment control system. The owner will be required to maintain these. <br /> 3. The Minnesota Plumbing Code is available on our website at: www.doli.state.mn.us/plumbing.html <br /> Prior to the installation of additional plumbing,not covered by this review,plans and specifications must be <br /> submitted to and approved by this office. <br /> Authorization for construction in accordance with the approved plans may be withdrawn if construction is not <br /> undertaken within a period of two years. The fact that the plans have been approved does not necessarily mean <br /> that recommendations or requirements for change will not be made at some later time when changed conditions, <br /> additional information,or advanced knowledge make improvements necessary. <br />