My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00379 - sprinkler system
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0450 Old Crystal Bay Road North - 33-118-23-13-0020
>
Permits/Inspections
>
2015-00379 - sprinkler system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:47:42 PM
Creation date
3/9/2018 11:47:59 AM
Metadata
Fields
Template:
x Address Old
House Number
450
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
450 Old Crystal Bay Road North
Document Type
Permits/Inspections
PIN
3311823130020
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TFP213 <br /> Page 2 of 4 <br /> 3 10 TEMPERATURE 2-9/16" DIA. <br /> RATING (65,0 mm) <br /> da kC C C <br /> — — <br /> — <br /> ,-, -7 2 m <br /> Orr <br /> ------ <br /> 11§1 <br /> 1- Frame 0���� "' _ <br /> 2- Deflector gill ' / tE0 \ ' '�(It if 1 -( _1`��_ 1 iiII -( V I 1 <br /> 3- Compression Screw 5 mil <br /> 4- Hook 4 3-3/4" <br /> 5- Strut I 5 <br /> (95,3 mm) <br /> II <br /> 6- Link Assembly M <br /> 7- Button 41. 6 .0'51 9/16" <br /> 8- Gasketed Spring Plate .00" a' . PP� (14,3 mm) <br /> 9- Ejection Spring NW 9 WRENCH ---....---11= NOMINAL <br /> 10- Deflector Nut a=yam FLATS MAKE-IN <br /> N 8 <br /> 'ISO 7-Ri pipe thread can <br /> be provided on special 7 <br /> request. S\ 1" NPT" <br /> 1 t <br /> FIGURE 1 <br /> MODEL EC-25 EXTENDED COVERAGE <br /> UPRIGHT SPRINKLER <br /> Design • The minimum distance between • NFPA obstruction rules for Extended <br /> sprinklers is 8 feet(2,44 m). Coverage Sprinklers must be utilized. <br /> Criteria • The minimum flow requirement is System Type <br /> based on the design density applied Wet pipe, dry pipe, and preaction sys- <br /> UL AND C-UL LISTING CRITERIA over the actual coverage area per tems are acceptable. <br /> sprinkler. <br /> NFPA 13, Chapter 12 through 20- For example: when sprinkler spac- FM APPROVAL CRITERIA <br /> Density/Area Design in is 14ft. x 12 ft.-bin. (4,3 m x 3,8 <br /> The TYCO Model EC-25 Extended m)or 175 ft2 (16,3 m2), and the de- FM Loss Prevention Data Sheets <br /> 2-0,3-26,and 8-9 <br /> Coverage Upright Sprinklers (TY9128) sign density is 0.6 GPM/ft2 (24,4 <br /> are UL and C-UL Listed for installation mm/min), the sprinkler design flow The TYCO Model EC-25 Extend- <br /> in accordance with the extended cov- rate is 105 GPM (397 LPM) and the ed Coverage Upright Sprinklers <br /> erage upright spray sprinkler require- required design pressure is 17.4 psi (TY9128) are FM Approved to be uti- <br /> ments of NFPA 13 or other applicable (1,2 bar). lized in accordance with the following <br /> NFPA standards when used in con- guidelines. <br /> junction with the following guidelines: • The minimum clearance between the <br /> deflector and the top of storage is 36 Application <br /> • Suitable for the protection of extra inches (0,9 m). For clearances of 36 The Model EC-25 Extended Cover- <br /> hazard and high-piled storage oc- inches (0,9 m) up to 48 inches (1,21 age Upright Sprinklers are FM Ap- <br /> cupancies where area/density de- m), the minimum design pressure is proved ceiling-level Storage Sprin- <br /> sign criteria are provided. 22 psi (1,52 bar). For clearances of klers for storage occupancy hazards <br /> • Suitable for"unobstructed" or 48 inches (1,21 m) and greater, the and other similar high heat release <br /> "noncombustible obstructed" minimum design pressure is estab- type fires. When compared with other <br /> construction. lished by the minimum flow require- FM Approved Storage Sprinklers, the <br /> ment. However, the pressure can Model EC-25 Sprinkler provides low <br /> • The Model EC-25 Sprinklers hav- never be less than 7 psi(0,5 bar). hydraulic demand,the spacing advan- <br /> ing been specifically tested and to of extended coverage, and the <br /> listed for noncombustible obstruct- • Ordinary and intermediate tern- es g g <br /> ed construction are suitable for use perature rated Model EC-25 Sprin- FM obstruction benefits of an upright <br /> within trusses or bar joists hav- klers have been investigated for use sprinkler. <br /> ing noncombustible web members in high-piled storage occupancies Model EC-25 Sprinklers should be <br /> greater than 1 inch (25,4 mm) when at the hydraulic demand normal- used in conformance with applicable <br /> applying the 4 times obstruction cri- ly associated with high tempera- FM Global Property Loss Prevention <br /> teria rule defined under "Obstruc- ture sprinklers. As such, the Model Data Sheets. <br /> tions to Sprinkler Discharge Pattern EC-25 Sprinklers are listed storage <br /> Development". sprinklers having a K-factor great- Hydraulic Design <br /> er than 11.2 (161,4) and having or- To determine the hydraulic design for <br /> • The maximum coverage area per dinary and intermediate tempera- . the Model EC-25 Sprinkler refer to the <br /> sprinkler is 196 ft2(18,2 m2). ture ratings (that is, 165°F or 74°C applicable FM Global Property Loss <br /> • The maximum distance between and 214°F or 101°C). Consequent- Prevention Data Sheet. <br /> sprinklers is 15 feet (4,6 m) when ly, the Model EC-25 Sprinklers, in <br /> the coverage area does not exceed accordance with NFPA 13, may be System Type <br /> 144 ft2 (13,4 m2), and the maximum used in conjunction with the den- Wet-pipe systems only <br /> distance between sprinklers is 14 sity curves for high temperature <br /> feet(4,3 m)when the coverage area sprinklers. <br /> does not exceed 196 ft2(18,2 m2). <br />