,b <br /> 1.- Residential Plans Examiner Review • Form <br /> ACC" • • • . • Equipment, RIPER 1.01 <br /> Arca�sa� 8 Mar 10 <br /> County, Town, Municipality, Jurisdiction <br /> Header Information <br /> Contractor REQUIRED ATTACHMENTS' ATTACHED <br /> Manual J1 Form(and supporting worksheets): Yes❑ No Z <br /> Mechanical License# or MJ1AE Form'(and supporting worksheets): Yes❑ No Z <br /> OEM performance data(heating,cooling,blower): Yes❑ No M <br /> Building Plan# Sys,2 Manual D Friction Rate Worksheet: Yes❑ Nog <br /> Duct distribution system sketch: Yes❑ No Z <br /> Home Address(Street or Lot#, Block, Subdivision) <br /> HVAC LOAD CALCULATION (IRC M1401 .3) <br /> Design Conditions Building Constr 1 _tion Information <br /> Winter Design Conditions Building <br /> Outdoor temperature 0 OF Orientation(Front door faces) North <br /> Indoor temperature 70 OF North,East,west, South,Northeast,Northwest,Southeast,Southwest <br /> Total heat loss 32977 Btu/h Number of bedrooms 0 <br /> Summer Design Conditions Conditioned floor area 896 Sq Ft <br /> Outdoor temperature go OF Number of occupants 2 <br /> Indoor temperature 79 OF Windows <br /> Roof <br /> Grains difference 3$ L Gr @ _9() % Rh Eave overhang depth Ft <br /> Sensible heat gain 1(2 11 Btu/h Internal shade <— <br /> Eave <br /> Latent heat gain 1835 Btu/h Blinds,drapes.etc Depth Window <br /> Total heat gain 12046 Btu/h Number of skylights <br /> EQUIPMENTHVAC •N (IRC M1401.3) <br /> Heating Equ*pmant Dat Copleng Fquipment Data Blower Data <br /> Equipment type Furnace Equipment type Standard Air Conditioner Q <br /> Furnace,Heat pump,Boller,etc. Air conditioner,Heat pump,etc Heating CFM 478 CFM <br /> Model Model <br /> Cooling CFM d78 CFM <br /> Heating output capacity Btu/h Sensible cooling capacity Btu/h <br /> Heat pumps-capacity at winter design outdoor conditions <br /> Latent cooling capacity Btu/h <br /> Auxiliary heat output capacity Btu/h Total cooling capacity Btu/h <br /> DISTRIBUTION,HVAC DUCT •1 <br /> Design airflow CFM Longest supply duct: Ft Duct Materials Used(circle) <br /> Trunk Duct: Duct board,Flex,Sheet metal, <br /> External Static Pressure(ESP) IWC Longest return duct: Ft Lined sheet metal, Other (specify) <br /> Component Pressure Losses(CPL) IWC Total Effective Length(TEL) Ft <br /> Branch Duct: Duct board,Flex,Sheet metal, <br /> Available Static Pressure(ASP) IWC Friction Rate: IWC Lined sheet metal, Other(specify) <br /> ASP=ESP-CPL Friction Rate=(ASP■100)+TEL <br /> above,I declare the load calculation, equipment selection, and duct system design were rigorously performed based on the building plan listed <br /> • e on -se forms will be subjectto review and verification. <br /> Contractor's Printed Name Date <br /> Contractor's Signature <br /> Reserved for use by County, Town, Municipality, or Authority having jurisdiction. <br /> We AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors,see list on page 2 of instructions. <br /> ' If abridged version of Manual J is used for load calculation,then verify residence meets requirements,see Abridged Edition Checklist on page 13 of instructions. <br /> Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program. <br />