.. /N% ..► - • - rm Form <br /> �\✓1"�® Examiner <br /> RIPER 1.01 <br /> ,��� OIATe ft • - • •. • Equipment, 8 Mar 10 <br /> County, Town, Municipality, Jurisdiction <br /> Header Information <br /> Contractor REQUIRED ATTACHMENTS' ATTACHED <br /> Manual J1 Form(and supporting worksheets): Yes❑ No Q <br /> Mechanical License# or MJ1AE Form'(and supporting worksheets): Yes❑ No M <br /> OEM performance data(heating,cooling,blower): Yes ElNo 0 <br /> Building Plan# Sys. 1 Manual D Friction Rate Worksheet: Yes❑ No 0 <br /> Duct distribution system sketch: Yes El Nog <br /> Home Address(Street or Lot#, Block, Subdivision) <br /> HVAC LOAD CALCULATION (IRC M1401 .3) <br /> Design Conditions Ruilding construction Information <br /> Winter Design Conditions Building <br /> Outdoor temperature 0 OF Orientation(Front door faces) North <br /> Indoor temperature 70 OF North,East,West, South,Northeast,Northwest,Southeast,Southwest <br /> Btu/h <br /> Total heat loss <br /> 299193 Number of bedrooms 0 <br /> Summer Design Conditions Conditioned floor area 6784 Sq Ft <br /> Outdoor temperature go OF Number of occupants _ 0 <br /> Indoor temperature 79 OF Windows <br /> Roof <br /> Grains difference 38 L Gr @� % Rh Eave overhang depth 0 Ft <br /> Sensible heat gain 86213 Btu/h <— <br /> Internal shade Eave <br /> Latent heat gain 16053 Btu/h Blinds,drapes,etc Depth Window <br /> Total heat gain 102266 Btu/h Number of skylights 0 <br /> EQUIPMENTIHVAC • 40 <br /> Hating Equipment Data Cooling Equipment Data Blower Data <br /> Equipment type Furnace Equipment type Standard Air Conditioner <br /> Fumaoe,Heat pump,Boiler,etc. Air Conditioner,Heat pump,etc Heating CFM 4039 CFM <br /> Model Model <br /> Cooling CFM 403A CFM <br /> Heating output capacity Btu/h Sensible cooling capacity Btu/h <br /> Heat pumps-capacity at winter design outdoor conditions <br /> Latent cooling capacity Btu/h <br /> Auxiliary heat output capacity Btu/h Total cooling capacity Btu/h <br /> DISTRIBUTIONHVAC DUCT •1 <br /> Design airflow CFM Longest supply duct: Ft Duct Materials Used(circle) <br /> Trunk Duct: Duct board,Flex,Sheet metal, <br /> External Static Pressure(ESP) IWC Longest return duct: Ft Lined sheet metal, Other (specify) <br /> Component Pressure Losses(CPL) IWC Total Effective Length(TEL) Ft <br /> Branch Duct: Duct board,Flex,Sheet metal, <br /> Available Static Pressure(ASP) IWC Friction Rate: IWC Lined sheet metal, Other(specify) <br /> ASP=ESP-CPL Friction Rate=(ASP■100)+TEL <br /> I declare the load calculation, equipment selection, and duct systern design were rigorOLISly performed based on the building plan listed <br /> above, I understand the claims made on these forms will be subject to review and verification. <br /> Contractor's Printed Name Date <br /> Contractor's Signature <br /> Reserved for use by County, Town, Municipality, or Authority having jurisdiction. <br /> a The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors,see list on page 2 of instructions. <br /> If abridged version of Manual J Is used for load calculation,then verify residence meets requirements,see Abridged Edition Checklist on page 13 of instructions. <br /> Form generated by ACCA-approved Manual J Eighth Edftlon Version 2 Elite Software Rhvec program. <br />