My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
furnace specs
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
furnace specs
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:03 PM
Creation date
2/22/2018 2:06:16 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.. /N% ..► - • - rm Form <br /> �\✓1"�® Examiner <br /> RIPER 1.01 <br /> ,��� OIATe ft • - • •. • Equipment, 8 Mar 10 <br /> County, Town, Municipality, Jurisdiction <br /> Header Information <br /> Contractor REQUIRED ATTACHMENTS' ATTACHED <br /> Manual J1 Form(and supporting worksheets): Yes❑ No Q <br /> Mechanical License# or MJ1AE Form'(and supporting worksheets): Yes❑ No M <br /> OEM performance data(heating,cooling,blower): Yes ElNo 0 <br /> Building Plan# Sys. 1 Manual D Friction Rate Worksheet: Yes❑ No 0 <br /> Duct distribution system sketch: Yes El Nog <br /> Home Address(Street or Lot#, Block, Subdivision) <br /> HVAC LOAD CALCULATION (IRC M1401 .3) <br /> Design Conditions Ruilding construction Information <br /> Winter Design Conditions Building <br /> Outdoor temperature 0 OF Orientation(Front door faces) North <br /> Indoor temperature 70 OF North,East,West, South,Northeast,Northwest,Southeast,Southwest <br /> Btu/h <br /> Total heat loss <br /> 299193 Number of bedrooms 0 <br /> Summer Design Conditions Conditioned floor area 6784 Sq Ft <br /> Outdoor temperature go OF Number of occupants _ 0 <br /> Indoor temperature 79 OF Windows <br /> Roof <br /> Grains difference 38 L Gr @� % Rh Eave overhang depth 0 Ft <br /> Sensible heat gain 86213 Btu/h <— <br /> Internal shade Eave <br /> Latent heat gain 16053 Btu/h Blinds,drapes,etc Depth Window <br /> Total heat gain 102266 Btu/h Number of skylights 0 <br /> EQUIPMENTIHVAC • 40 <br /> Hating Equipment Data Cooling Equipment Data Blower Data <br /> Equipment type Furnace Equipment type Standard Air Conditioner <br /> Fumaoe,Heat pump,Boiler,etc. Air Conditioner,Heat pump,etc Heating CFM 4039 CFM <br /> Model Model <br /> Cooling CFM 403A CFM <br /> Heating output capacity Btu/h Sensible cooling capacity Btu/h <br /> Heat pumps-capacity at winter design outdoor conditions <br /> Latent cooling capacity Btu/h <br /> Auxiliary heat output capacity Btu/h Total cooling capacity Btu/h <br /> DISTRIBUTIONHVAC DUCT •1 <br /> Design airflow CFM Longest supply duct: Ft Duct Materials Used(circle) <br /> Trunk Duct: Duct board,Flex,Sheet metal, <br /> External Static Pressure(ESP) IWC Longest return duct: Ft Lined sheet metal, Other (specify) <br /> Component Pressure Losses(CPL) IWC Total Effective Length(TEL) Ft <br /> Branch Duct: Duct board,Flex,Sheet metal, <br /> Available Static Pressure(ASP) IWC Friction Rate: IWC Lined sheet metal, Other(specify) <br /> ASP=ESP-CPL Friction Rate=(ASP■100)+TEL <br /> I declare the load calculation, equipment selection, and duct systern design were rigorOLISly performed based on the building plan listed <br /> above, I understand the claims made on these forms will be subject to review and verification. <br /> Contractor's Printed Name Date <br /> Contractor's Signature <br /> Reserved for use by County, Town, Municipality, or Authority having jurisdiction. <br /> a The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors,see list on page 2 of instructions. <br /> If abridged version of Manual J Is used for load calculation,then verify residence meets requirements,see Abridged Edition Checklist on page 13 of instructions. <br /> Form generated by ACCA-approved Manual J Eighth Edftlon Version 2 Elite Software Rhvec program. <br />
The URL can be used to link to this page
Your browser does not support the video tag.