My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Mech/Elect project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Mech/Elect project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:04 PM
Creation date
2/22/2018 2:03:43 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Cleanout Types: Install floor and wall cleanout for concealed piping, types as indicated. Provide floor cleanouts , <br /> with features described below, suitable for use in the following special applications to match floor finishes;refer to <br /> schedule on Architects Drawings for room finish: <br /> 1. Carpeted floors: 'Round top with stainless steel carpet marker and vandal proof exposed screw. <br /> 2. Other finished areas: Satin polished round top with vandal proof screws. <br /> 3. Unfinished areas: Heavy duty,round cast-iron top with standard mill finish. <br /> E. Flashing Flanges: Install flashing flange and clamping device with each stack and cleanout passing through <br /> waterproof membranes. <br /> F. Vent Flashing Sleeves: Install on stacks passing through roof, secure over stack flashing in accordance with <br /> manufacturer's instructions. <br /> 3.06 INSTALLATION OF FLOOR DRAINS <br /> A. Install floor drains in accordance with manufacturer's written instructions and in locations indicated. <br /> B. Install floor drains at low points of surface areas to be drained, or as indicated. Set tops of drains flush with <br /> finished floor. <br /> C. Set drain elevation depressed below finished slab elevation as listed below to provide proper slope to drain: <br /> DEPRESSION RADIUS OF AREA DRAINED <br /> 1/2" 5'-0" <br /> 3/4" 10'-0" <br /> 1" 15'-0" <br /> 20'-0" <br /> 25'-0" <br /> D. Trap all drains connected to the sanitary sewer. <br /> E. Install drain flashing collar or flange so that no leakage occurs between drain and adjoining flooring. Maintain <br /> integrity of waterproof membranes,where penetrated <br /> F. Position drains so that they are accessible and easy to maintain. <br /> 3.07 INSTALLATION OF TRAP PREKERS <br /> A. Install trap primers with piping pitched towards drain trap, minimum of 1/8" per foot (1 percent). Adjust trap <br /> primer for proper flow. <br /> 3.08 INSTALLATION OF SUMP BASINS <br /> A. Install basin with anchoring flange and mud ring set in concrete floor slab. Excavate to provide minimum 12" of <br /> pea gravel backfill on all sides and at bottom. <br /> 3.09 CONNECTIONS <br /> A. Piping Runouts to Fixtures: Provide drainage and vent piping runouts to plumbing fixtures and drains, with <br /> approved trap,of sizes indicated;but in no case smaller than required by Minnesota Plumbing Code. <br /> 15412-6 No.99132-CP2 <br />