My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Mech/Elect project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Mech/Elect project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:04 PM
Creation date
2/22/2018 2:03:43 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1) Coils with more than 12 circuits shall have two distributors. <br /> 2) Split circuit coils shall have two distributors. <br /> F. Dampers: <br /> 1. General: Leakage rate when tested in accordance with AMCA Standard 500 - Test Method for Louvers, <br /> Dampers and Shutters,shall not exceed 2 percent of air quantity calculated at 2,000 fpm face velocity through <br /> damper and 4.0 inches w.g.pressure differential. <br /> a. Damper operators are specified in Division 15 Section 15970 "Energy Management and Control <br /> Systems". <br /> 2. Provide inlet guide vane dampers as indicated or required. <br /> G. Filters Section: <br /> 1. General: Filters shall comply with NFPA Standard 90A"Standard for the Installation of Air Conditioning and <br /> Ventilating Systems." <br /> 2. Access Doors: Same material as cabinets complete with hinges,latches,handles and gaskets. <br /> 3. Extended Surface Filters: Provide filter section and media as indicated. <br /> a. Pre-Filters: Provide disposable type air filters 2 inches thick, consisting of viscous coated fibers with <br /> filtering media encased in fiberboard cell sides having perforated metal grids on each face to provide <br /> media support Airflow resistance with clean media shall not exceed 0.10 inch w.g. at face velocity of <br /> 300 fpm, and filter arrestance efficiency of 70 to 82 percent based on ASHRAE Test Standard 52 - <br /> Method of Testing Air-Cleaning Devices Used in General Ventilation for Removing Particulate Matter. <br /> b. Extended Surface Self-Supporting Filters: Provide factory-fabricated, dry, extended surface self- <br /> supporting filters with holding frames; where indicated, in sizes indicated. Equip with UL Class 1 <br /> fibrous media material constructed so that individual pleats are maintained in tapered form by flexible <br /> internal supports under rated air flow conditions. Construct holding frames of 18-ga galvanized steel and <br /> provide suitable fasteners and gasketing to hold filter units and to prevent unfiltered air passing between <br /> media frames and holding devices. Design holding frames which are suitable for bolting together into <br /> built-up filter banks. Provide filters with rated face velocity of 500 fpm, initial resistance of 0.25"w.g. <br /> with 60-65% dustspot efficiency, 0.40" w.g. with 80-85% efficiency, and 0.70" w.g. with 90-95% <br /> efficiency,and final rated resistance of 1.0"w.g. <br /> H. Vibration Control: <br /> 1. Spring Isolators, Housed: Except as otherwise indicated, provide vibration isolation spring between <br /> telescoping steel housings with top and bottom loading plates, and with pad-type isolator bonded to bottom of <br /> loading plate. Include resilient inserts to separate and guide telescoping housings. <br /> a. Equip top loading plate with equipment anchorages as indicated or as required for support and <br /> attachment <br /> b. Include pad-type isolator bonded to top of top loading plate,except on units with leveling bolts. <br /> c. Include holes in bottom plate for bolting unit to substrate. <br /> 2.05 EXTRA MATERIALS <br /> A. Furnish one additional complete set of belts for each central-station air-handling unit <br /> 15854-10 No.99132-CP2 <br />