My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Construction project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Construction project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:02 PM
Creation date
2/22/2018 1:41:15 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
271
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I. AAMA 608.1-77: Voluntary Guide Specifications and Inspection Methods for Electrolytically Deposited Color ' <br /> Anodic Finishes for Architectural Aluminum. <br /> J. ASTM E 283-84— Standard Test Method for Rate of Air Leakage Through Exterior Windows,Curtain Walls, and <br /> Doors; 1984. <br /> K. ASTM E330-84 — Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and <br /> Doors by Uniform Static Air Pressure Difference; 1984. ' <br /> L. ASTM E331-86—Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls,and Doors by <br /> Uniform Static Air Pressure Difference; 1986. , <br /> M. ASTM C 509-84—Specification for Cellular Elastomeric Preformed Gasket and Sealing Material. <br /> N. ASTM D 3656-89 — Specification for Insect Screening and Louver Cloth Woven from Vinyl-Coated Glass Fiber , <br /> Yam. <br /> O. ASTM E 783-84—Method for Field Measurement of Air Leakage Through Installed Exterior Windows and Doors. ' <br /> P. ASTM E 1105-86 — Test Method for Field Determination of Water Penetration of Installed Exterior Windows, <br /> Curtain Walls,and Doors by Uniform Cyclic Static Pressure Difference. ' <br /> Q. ASTM F 588-85—Test Method for Resistance of Window Assemblies to Forced Entry Excluding Glazing. <br /> 1.04 PERFORMANCE REQUIREMENTS ' <br /> A. Exterior Assemblies: Design and fabricate to comply with the performance characteristics listed below. <br /> B. Thermal Movement: Allow for expansion and contraction resulting from ambient temperature range of 120 degrees ' <br /> F(49 degrees Q. <br /> C. Wind Loading: Provide capacity to withstand the following loadings without deformation and without deflection ' <br /> greater than 1/175 of span: <br /> 1. Uniform pressure of 20 psf inward. ' <br /> 2. Uniform pressure of 20 psf outward. <br /> D. Condensation Resistance: Where framing systems are "thermal-break" construction, provide units tested for , <br /> thermal performance in accordance with AAMA 1503 showing condensation resistance factor (CRF) of not less <br /> than: 45 for single and double hung and 50 for all others. <br /> E. Thermal Transmittance: Provide framing systems that have an overall U-valve of not more than 0.65 BTU/(hr.x sq. , <br /> ft.x deg.F)at 15 mph exterior wind velocity when tested in accordance with AAMA 1503. <br /> F. Air Infiltration Rate <br /> 1. Fixed windows/storefront/entrance curtainwall not be more than 0.06 cfin per sq. ft. of window area for an <br /> inward test pressure of 6.24 lbf per sq.ft.,when tested in accordance with ASTM E 283. , <br /> G. Water Penetration: There will be not water penetration,as defined in ASTM E 331,when tested in accordance with <br /> ASTM E 331 at an inward test pressure of 10.00(6.24 for storefront)lb per sq.ft. , <br /> 08521-2 No.99132-CP2 , <br />
The URL can be used to link to this page
Your browser does not support the video tag.