Laserfiche WebLink
I. AAMA 608.1-77: Voluntary Guide Specifications and Inspection Methods for Electrolytically Deposited Color ' <br /> Anodic Finishes for Architectural Aluminum. <br /> J. ASTM E 283-84— Standard Test Method for Rate of Air Leakage Through Exterior Windows,Curtain Walls, and <br /> Doors; 1984. <br /> K. ASTM E330-84 — Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and <br /> Doors by Uniform Static Air Pressure Difference; 1984. ' <br /> L. ASTM E331-86—Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls,and Doors by <br /> Uniform Static Air Pressure Difference; 1986. , <br /> M. ASTM C 509-84—Specification for Cellular Elastomeric Preformed Gasket and Sealing Material. <br /> N. ASTM D 3656-89 — Specification for Insect Screening and Louver Cloth Woven from Vinyl-Coated Glass Fiber , <br /> Yam. <br /> O. ASTM E 783-84—Method for Field Measurement of Air Leakage Through Installed Exterior Windows and Doors. ' <br /> P. ASTM E 1105-86 — Test Method for Field Determination of Water Penetration of Installed Exterior Windows, <br /> Curtain Walls,and Doors by Uniform Cyclic Static Pressure Difference. ' <br /> Q. ASTM F 588-85—Test Method for Resistance of Window Assemblies to Forced Entry Excluding Glazing. <br /> 1.04 PERFORMANCE REQUIREMENTS ' <br /> A. Exterior Assemblies: Design and fabricate to comply with the performance characteristics listed below. <br /> B. Thermal Movement: Allow for expansion and contraction resulting from ambient temperature range of 120 degrees ' <br /> F(49 degrees Q. <br /> C. Wind Loading: Provide capacity to withstand the following loadings without deformation and without deflection ' <br /> greater than 1/175 of span: <br /> 1. Uniform pressure of 20 psf inward. ' <br /> 2. Uniform pressure of 20 psf outward. <br /> D. Condensation Resistance: Where framing systems are "thermal-break" construction, provide units tested for , <br /> thermal performance in accordance with AAMA 1503 showing condensation resistance factor (CRF) of not less <br /> than: 45 for single and double hung and 50 for all others. <br /> E. Thermal Transmittance: Provide framing systems that have an overall U-valve of not more than 0.65 BTU/(hr.x sq. , <br /> ft.x deg.F)at 15 mph exterior wind velocity when tested in accordance with AAMA 1503. <br /> F. Air Infiltration Rate <br /> 1. Fixed windows/storefront/entrance curtainwall not be more than 0.06 cfin per sq. ft. of window area for an <br /> inward test pressure of 6.24 lbf per sq.ft.,when tested in accordance with ASTM E 283. , <br /> G. Water Penetration: There will be not water penetration,as defined in ASTM E 331,when tested in accordance with <br /> ASTM E 331 at an inward test pressure of 10.00(6.24 for storefront)lb per sq.ft. , <br /> 08521-2 No.99132-CP2 , <br />