My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Construction project manual-2000/Media center
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0685 Old Crystal Bay Road North - 33-118-23-21-0002
>
Misc
>
Construction project manual-2000/Media center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:48:02 PM
Creation date
2/22/2018 1:41:15 PM
Metadata
Fields
Template:
x Address Old
House Number
685
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
685 Old Crystal Bay Road North
Document Type
Misc
PIN
3311823210002
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
271
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 03600 <br /> GROUT <br /> PART 1: GENERAL <br /> 1.01 APPLICABLE DOCUMENTS <br /> A. Bidding Requirements, Conditions of the Contract and pertinent portions of Sections in Division One of these <br /> Specifications apply to the Work of this Section. <br /> 1.02 SUMMARY <br /> A. Work includes: Furnishing and placing of grout for steel base plates,grout bedding for equipment,grout for anchor <br /> bolt settings,grout for concrete surface repair,and all other grout not specified elsewhere. <br /> B. Related work specified in other sections: <br /> 1. Cast-in-place concrete-Section 03300. <br /> 2. Grout for filling cores in masonry-Section 04200. <br /> 1.03 REFERENCE STANDARDS <br /> A. The following specifications and standards are incorporated by reference. Materials and operations shall comply <br /> with requirements of latest issue of published reference. Where provisions of these Project Specifications are at <br /> variance with those reference specifications,the maximum criteria or requirements shall govern. <br /> 1. ASTM American Society for Testing and Materials(specific standards denoted in Part 2 of this section). <br /> 2. Corps of Engineers Specifications for Non-Shrink Grout-CRD C-621. <br /> 1.04 QUALITY ASSURANCE <br /> A. Work shall comply with the referenced standards and codes. <br /> 1.05 SUBMITTALS <br /> ' A. Make submittals in accordance with Section 01300. <br /> B. Submit manufacturer's technical data sheets demonstrating compliance with the specifications. <br /> C. Submit copies of recent independent laboratory tests certifying technical compliance. <br /> 1.06 PRODUCT DELIVERY,STORAGE AND HANDLING <br /> A. Grout may be job mixed or ready mixed. If job mixed, mix in a power operated machine until there is uniform <br /> distribution of materials and mixture is uniform in composition and consistency. Completely discharge each batch <br /> before mixture is,recharged. <br /> B. Mix and deliver ready-mixed"grout in accordance with ASTM C94. Place grout within one(1)hour of time mix <br /> is placed in truck. <br /> C. Do not indiscriminately re-temper or add water to increase slump after concrete is first mixed. <br /> 03600-1 No.99132-CP2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.