Laserfiche WebLink
DN-60054:A•H-320 <br /> Intelligent Bases <br /> s2246i(A), 13224RB(A)„6501(A), 1350113H(A), rJ NOTIFIER <br /> 135010H-2(A), 8501 BHT(A), 0501 BHT 2(A), by Honeywell <br /> 071OLP(A), Mounting Kits, and Accessories <br /> General <br /> Intelligent FlashScan®and CLIP mounting bases and kits pro- <br /> vide a variety of ways to install NOTIFIER detectors in any appli- <br /> cation.Intelligent detectors can be mounted in either flanged or , <br /> flangeless bases depending on junction box selection (see <br /> Junction Box Selection Guide).Across this product line,detec- <br /> tors plug in easily to the base with SEMS screws; and models Flangeless Mounting Base Relay Base <br /> employ various 12 to 22 AWG wire ranges. <br /> Relay,Isolator,and sounder bases can be used to meet local <br /> code requirements. Relay bases provide one Form-C contact <br /> relay for control of auxiliary functions such as door closure and ► <br /> elevator recall.Isolator bases allow loops to continue to operate <br /> under fault conditions and automatically restore when the fault is I( ' <br /> removed. Sounder bases are available in temporal and non- 9 <br /> temporal pattern versions depending on whether the signal is to I <br /> be used for evacuation purposes. Flanged Mounting Base e Recessed Mounting <br /> The RMK400 recessed mounting kit provides the most aes- <br /> thetically pleasing installation. Surface mounting boxes are <br /> available when flush mounting isn't possible. fi <br /> Specifications - <br /> Diameter: For B501: 4.1” (104 mm). For B224B1, B224RB, - <br /> B710LP: 6.1" (155 mm). For B501BH, B501BH-2, B501BHT, <br /> B501BHT-2:6.0"(152 mm). Standard Sounder Base Flangeless Surface Mounting <br /> Wire gauge: for B224B1, B224RB: 14 to 24 AWG. For <br /> B710LP,B501,B501BH,B501BH-2,B501BHT,B501BHT-2: 12 Maximum ripple voltage: 10%of supply voltage. <br /> to 18 AWG. <br /> Temperature range:For B224B1, B224RB, B501BH, B501BH- Startup capacitance:200 NF. <br /> 2, B501BHT, B501BHT-2: 32°F to 120°F (0°C to 49°C). For Set time: for B501BH and B501BHT, 6 to 15 seconds. For <br /> B501 and B710LP,32°F to 150°F(0°C to 66°C). B501BH-2 and B501BHT-2,0.75 to 5.7 seconds. <br /> Humidity range:10%to 93%RH,non-condensing. Sound output: greater than 90 dBA measured in anechoic <br /> System temperature and humidity ranges: This system room at 10 feet (3.048 m), 24 volts. 85 dBA minimum in UL <br /> meets NFPA requirements for operation at 0'C to 49'C(32"F to reverberant room. <br /> 120°F); and at a relative humidity (noncondensing) of 85% at <br /> 30°C(86°F)per NFPA,and 93%t 2%at 32°C t 2"C(89.6`F t Recessed Mounting Kit <br /> 1.1°F)per ULC.However,the useful life of the system's standby The RMK400 can be used with drywall or suspended ceilings. <br /> batteries and the electronic components may be adversely The aesthetically pleasing design can be used with standard <br /> affected by extreme temperature ranges and humidity. There- junction boxes—suitable for use with 4.0"(10.16 cm)octago- <br /> fore, it is recommended that this system and all peripherals be nal, 50 mm, and 60 mm junction boxes connected to flexible <br /> installed in an environment with a nominal room temperature of conduit. Note that junction boxes are not included in the kit.As <br /> 15°C to 27°C(60°F to 80°F). an application example,with the 8501 base,the RMK400 pro- <br /> vides a simple installation solution in applications that demand a <br /> Electrical Ratings lower-profile smoke detector. <br /> FOR B224RB,B22461: Agency Listings <br /> Operating voltage: 15 to 32 VDC(powered by SLC). g y and Approvals <br /> Standby ratings:<500 NA maximum @ 24 VDC. The listings and approvals below apply to intelligent bases as <br /> noted. In some cases,certain modules or applications may not <br /> Set time(B224RB only):short delay 55 to 90 msec;long delay be listed by certain approval agencies,or listing may be in pro- <br /> 6 to 9 seconds. cess.Consult factory for latest listing status. <br /> Reset time(B224RB only):20 msec maximum. Listing information to be provided in upcoming edits. Consult <br /> Relay characteristics (B224RB only): two-coil latching relay; panel manuals for lists of compatible UL-Listed devices. All <br /> one Form-C contact;ratings(UUCSA):0.9 A @ 125 VAC,0.9 A bases have been previously listed for use with various panels. <br /> @ 110 VDC,and 3.0 A @ 30 VDC. <br /> FOR B501BH,B501BH-2,B501BHT,B501BHT-2: Product Line Information <br /> External supply voltage: 17 to 32 VDC. INTELLIGENT BASES <br /> Standby current:1.0 mA maximum. B6011 Flangeless mounting base. <br /> Alarm current: 15 mA maximum. B501A: Flangeless mounting base,ULC Listed. <br /> DN-60054A•11/30/06—Page 1 of 2 <br />