Laserfiche WebLink
FMM-101(A) Mini Monitor Module Dimensions: 1.3° (3.302 cm) high x 2.75° (6.985 cm)wide x <br /> • Built-in type identification automatically identifies this device 0.65°(1.651 cm)deep. <br /> as a monitor module to the panel. Wire length:6•(15.24 cm)minimum. <br /> • Powered directly by two-wire SLC loop.No additional power <br /> required. FZM4(A) Interface Module <br /> • High noise(EMF/RFI)immunity. • Supports compatible two-wire smoke detectors. <br /> • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power <br /> • Direct-dial entry of address:01 —159 on FlashScan loops; source. <br /> 01—99 on CLIP loops. • High noise(EMF/RFI)immunity. <br /> • SEMS screws with clamping plates for ease of wiring. <br /> 3 1415 0 1 ADDRESS 0 1 • Direct-dial entry of address:01 —159 on FlashScan loops, <br /> 13 2 2 01 —99 on CLIP loops. <br /> 12 O 3 LOOP O 3 • LED flashes during normal operation;this is a programma- <br /> 11 4 4 ble option. <br /> • LED latches steady to indicate alarm on command from <br /> 10 g 8 7 6 5 9 8 7 6 control panel. <br /> TENS ONES <br /> The FZM-1(A) Interface Module is intended for use in intelli- <br /> gent, addressable systems, where the individual address of <br /> each module is selected using built-in rotary switches. This <br /> module allows intelligent panels to interface and monitor two- <br /> wire conventional smoke detectors.It transmits the status(nor- <br /> mal,open,or alarm)of one full zone of conventional detectors <br /> 0p back to the control panel. All two-wire detectors being moni- <br /> tored must be UL compatible with the module. The FZM-1(A) <br /> can be used to replace MMX-2(A) modules in existing sys- <br /> tems. <br /> FZM-1(A) APPLICATIONS <br /> The FMM-101(A) Mini Monitor Module can be installed in a Use the FZM-1(A)to monitor a zone of two-wire smoke detec- <br /> single-gang junction directly behind the monitored unit. Its tors.The monitored circuit may be wired as an NFPA Style B <br /> small size and light weight allow it to be installed without rigid (Class B)or Style D(Class A)Initiating Device Circuit.A 3.9 K <br /> mounting. The FMM-101(A) is intended for use in intelligent, ohm End-of-Line Resistor(provided)terminates the end of the <br /> two-wire systems where the individual address of each module Style B or D (class B or A) circuit(maximum IDC loop resis- <br /> is selected using rotary switches. It provides a two-wire initiat- tance is 25 ohms). Install ELR across terminals 8 and 9 for <br /> ing device circuit for normally-open-contact fire alarm and Style D application. <br /> security devices. The FMM-101(A) can be used to replace <br /> MMX-101(A)modules in existing systems. FZM-1(A)OPERATION <br /> FMM-101(A)APPLICATIONS Each FZM-1(A) uses one of the available module addresses <br /> on an SLC loop. It responds to regular polis from the control <br /> Use to monitor a single device or a zone of four-wire smoke panel and reports its type and the status(open/normaVshort) <br /> detectors,manual fire alarm pull stations,waterflow devices,or of its Initiating Device Circuit(IDC). A flashing LED indicates <br /> other normally-open dry-contact devices. May also be used to that the module is in communication with the control panel. <br /> monitor normally-open supervisory devices with special super- The LED latches steady on alarm (subject to current limita- <br /> visory indication at the control panel. Monitored circuit/device tions on the loop). <br /> is wired as an NFPA Style B(Class B)Initiating Device Circuit. <br /> A 47K ohm End-of-Line Resistor(provided)terminates the cir- FZM-1(A)SPECIFICATIONS <br /> cuit. Nominal operating voltage:15 to 32 VDC. <br /> FMM-101(A)OPERATION Maximum current draw:5.1 mA(LED on). <br /> Each FMM-101(A) uses one of the available module Maximum IDC wiring resistance:25 ohms. <br /> addresses on an SLC loop. It responds to regular polls from Average operating current:300 NA, 1 communication and 1 <br /> the control panel and reports its type and the status(open/nor- LED flash every 5 seconds,3.9k sol. <br /> mal/short)of its Initiating Device Circuit(IDC). <br /> EOL resistance:3.9K ohms. <br /> FMM-101(A) SPECIFICATIONS External supply voltage (between Terminals T3 and T4): <br /> Nominal operating voltage:15 to 32 VDC. DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms <br /> Average operating current:350 NA, 1 communication every maximum.Current:90 mA per module maximum. <br /> 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Temperature range:32°F to 120°F(0°C to 490C). <br /> Shorted). Humidity range:10%to 93%noncondensing. <br /> Maximum IDC wiring resistance:40 ohms. Dimensions: 4.5• (11.43 cm) high x 4• (10.16 cm) wide x <br /> Maximum IDC Voltage: 11 Volts. 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x <br /> Maximum IDC Current:400 NA. 2.125°(5.398 cm)deep box. <br /> EOL resistance:47K ohms. <br /> Temperature range:32°F to 120°F(0°C to 490C). <br /> Humidity range: 10%to 93%noncondensing. <br /> Page 2 of 4—DN-6720:C•10/06/2010 <br />