GAS LOG LIGHTER <br /> Installation of a gas log lighter shall comply <br /> with the State Mechanical Code for gas appliances. <br /> The gas shut off valve shall be a listed A.G.A. <br /> device and must be outside the masonry fireplace <br /> c.1v.w. and not embedded in the outside hearth. A swing <br /> joint consisting of at least three elbows should <br /> be installed between the gas shut off va)ve and <br /> the log lighter pipe. This is to prevent breaks <br /> in the joints in the event of movement or settle- <br /> FIREPLACE LOG LIGHTER ment of the fireplace. <br /> It is recommended that the gas log lighter be <br /> 1" above the ash bed and definitely not buried in <br /> the ashes or in sand. <br /> FLUE AND CHIMNEY SIZES <br /> 48 <br /> Nominal Actual Outside Effective Max.Area of Minimum Outsid <br /> 46 ?� Dimension of Dimensions of Flue Fireplace Dimension of <br /> ,c Flue Lining Flue Lining Area Opening Chimney <br /> / + <br /> 8X" Round 8%" Round 39 sq. in. 390 sq.in. 17"x 117- <br /> 8%" <br /> Y'8%"x 13"oval 8%" x 12%" 69 sq. in. 690 sq.in. 17"x 21" <br /> 42 + `fl 8%"x 17"oval 8%" x 16%" 87 sq. in. 870 sq.in. 17" x 25" <br /> 13" Round 12%" Round 91 sq. in. 1092 sq. in. 21"x 21- <br /> 40 �� X13 / i 10" c 18"oval 10" x 17%- 112 sq. in. 1120 sq.in. 19" x 26" <br /> s 1Q" x 21"oval 10"' x 21'" 138 sq. in. 1380 sq.in. 19" x 30' <br /> 38 �� `3,. D� 13" x 17"oval 12%" x 16%" 134 sq. in. 1340 sq.in. 21" x 25" <br /> + <br /> Q a � Al �i 13" x 21"oval 12%"x 21" 173 sq. in. 1730 sq.in. 21"x 30" <br /> 36 i� +� � t7" x 17"oval 16jL"x 16j4 171 sq. in. 1710 sq.in. 25" x 25" <br /> CP <br /> r� +II--"—�� D 17" x 21"oval 16X"x 21" 223 sq. in. 2230 sq.in. 25" x 30" <br /> �° 21"x 21"'oval 21" x 21'" 269 in. 2690 <br /> 3! � �j. J+ � ;� P�� sq. ' sq. in. 30" x 30.. <br /> 32 `S <br /> CPFLUE SIZES <br /> f. 9 � � ?. `moo - <br /> 30 <br /> %� �1 The area of the fireplace opening is multiplied <br /> 28 CO�f�'�j � / by the flue area ratio to obtain the minimum <br />;8 T, required effective flue area. <br /> t4 The size of the modular flue lining selected <br /> 24 28 32 38 40 44 48 62 ' 68 60 64 68 74 shcul d be equal to or larger than the required <br /> computed area. <br /> Width of Fireplace Opening (Inches) PRCBLEM: <br /> Find proper flue size at 1/10 fireplace area <br /> GRAPH TO DETERMINE PROPER FLUE SIZE for a fireplace 48" wide by 30" high. <br /> FOR SINGLE FACE FIREPLACE SOLUTION: <br /> 1 . Find 48" fireplace width at bottom of chart. <br /> 2. Find 30" fireplace height at left side of <br /> chart. <br /> 3. Follow height line across and width line up <br /> until they intersect. <br /> 4. Proper flue size will be nearest curve above <br /> intersection. Use 17" x 17" or 13" x 21" <br /> nominal flue lining size. <br />