Laserfiche WebLink
• <br /> 2060 Wayzata Blvd:Day Care Code Review <br /> November 18,2016 I <br /> Page Two i I <br /> 1009.3 Exit Access Stair:Floor Enclosure <br /> Exception 1: Stairways serving only two stories.(does not include mezzanine)—not required <br /> to be enclosed. <br /> 9. Table 1014.3 Common Path of Egress Travel: <br /> a. E occupancy=75'-0": Main level and Basement Level complies. <br /> b. B occupancy 100': Mezzanine level complies <br /> 10. Table 1016.2 Exit Access Travel Distance: Group E: 250'-0" <br /> 11. 1018 Corridors: Both Group E: <br /> Corridors not required to be fire rated if the building is fully sprinkled. <br /> 12. 1018.4 Dead End Corridors <br /> Group E:50'-0" if sprinkled <br /> 13. 1018.2 Corridor Width required <br /> Group E: 72" if occupant load is over 100. Building complies <br /> 14. Table 1021.2 Stories with one exit or access to one exit <br /> a. 1-4 not allowed on Mezzanine level with only one exit. <br /> b. Main Level: 75'to exit: Building complies <br /> c. Basement Level: 75'to exit: Building complies <br /> 15. 1104 Accessible Route <br /> a. Basement Level:if path to exterior door is accessible(1:20 ramp)then floor complies.If <br /> accessible exterior path does not exist then a lift(LULA)is required from Main level to <br /> Basement level. <br /> b. Main Level: if no stairs to the main entry then this level complies with code: <br /> c. Mezzanine Level: If this level is less than 30 occupants then this level complies.No lift or <br /> elevator needed <br /> 16. Table 2902.1 Plumbing fixture count <br /> Group E Water Closets: 1 per 50 occupants <br /> Lavatories: 1 per 50 occupants <br /> Drinking Fountain 1 per 100 occupants <br /> Service Sink 1 <br /> a. Restrooms need to be located on accessible routs;therefor the Main level will need to add <br /> restrooms <br /> b. 2902.3.2:Accessible restrooms need to be within one floor and 500'of a space.If restroom are <br /> added to Main level,then Mezzanine level will comply with this code. <br /> •diti•i- •a a • it: '•a . MN i. . •503 <br /> 1. Outdoor play area:min. 1,500 SF,fenced off.: <br /> 2. Electrical outlets to be tamper proof. <br /> 3. Large muscle activity area needed <br /> 4. One handwashing sink and water closet for every 15 students <br /> Further Discussion <br /> 1. Rooms with Children 2.5 years and younger need a direct exit door out. <br /> 2. Restroom fixture count RECEIVED <br /> 3. Food Prep Area location <br /> JAN 1 7 2017 <br /> MOHAGEN HANSEN <br /> Architecture{Interiors CITY OF ORONO <br /> Jennifer Kaplan,AIA <br /> Architect K\Joba\2060 Wayzata-Blvd-16403\01-4dmin\Code\16403_Code Review Daycare.doar <br /> MONASEN HANSEN it 3 8 98 <br /> Architecture!Interiors <br />