Laserfiche WebLink
i1 <br /> MCHAGEN h ANSEN <br /> PC Exhibit E <br /> November 22, 2016 <br /> Re: Building Code Review for Daycare Occupancies <br /> 2060 Wayzata Blvd,Orono, MN <br /> Mohagen Hansen Project No.: 16403.0CBS <br /> This document will provide a basic code review for the building located at 2060 Wayzata Blvd, Orono, <br /> MN.This code review will be focused on providing the requirements for an occupancy for a Day Care <br /> within the Minnesota State Building Code 2015 and the MN State Fire Code 2015.This review does not <br /> include the MN Chapter 9503 Child Care Center Licensing. <br /> Basic Building Current Information: <br /> 1. Occupancy: B(Business) <br /> 2. Building Construction Type: Type V-B <br /> 3. Stories: 1 with a Mezzanine and Basement <br /> 4. Square Feet per Floor: Basement Level: 1563 SF;Main Level: 154.6 SF; Mezzanine:749 <br /> SF <br /> 5. Sprinkled Fully Sprinkled, NFPA 13 <br /> 6. Exiting 2 exits,one on main level and one on basement level <br /> Day Care Review: <br /> 1. Occupancy Classification Table 302.2 <br /> More than 5 children under 2.5 years of age without exit on level of classrooms: 1-4 <br /> i. Mezzanine level : 1-4 occupancy not allowed by item#14 <br /> b. More than 5 but less than 100 children less than 2.5 years on level of exit: E <br /> i. Main level or Basement level:E occupancy with direct access out of classroom. <br /> Exit doors need to be added. <br /> c. More than5 children greater than 2.5 years: 1- <br /> i. Main level or Basement level: E occupancy, no additional exiting required <br /> ii. Mezzanine level: E occupancy if exit door is added. <br /> Table 503 Building Height and Size: E <br /> Allowable: 1stories and 9,500SF per floor <br /> Provided: 2 stories and approx.. 1600 SF or less per floor <br /> 3. 504.2 Automatic sprinkler system increase. <br /> a. Allowable stories increased by one story. <br /> 4. Table 803.9 Interior Finish Requirements for Flame Spreads <br /> Group E:Exits- Group B <br /> Corridors, Rooms Group C <br /> Flame spread for C: 76-200 <br /> Smoke Development Index: 0-450 <br /> 5. 906 Fire Extinguisher:to be located a maximum travel distance of 75'-0" <br /> 6. Table 1004.1.4 Maximum floor area per occupant: RECEIVED <br /> Group E:Day care:35-any classroom over 1,715 SF needs two exits <br /> 7. 1008.1.10: Panic Hardware:Group E:is Required, JAN 1 7 2017 <br /> 8. 1009 Stairways 3 + <br /> c : 1 ._ .• o:ks.. r. Give ! S,Htr ?Ofi.1`:iy:. i.'A`I 5554' 8 98 CITY OFORONO <br />