My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
info on exterior insulation/filling material, etc.-1999
Orono
>
Property Files
>
Street Address
>
N
>
North Shore Drive
>
4753 North Shore Drive - 07-117-23-32-0020
>
Misc
>
info on exterior insulation/filling material, etc.-1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:35:07 PM
Creation date
1/31/2018 3:38:49 PM
Metadata
Fields
Template:
x Address Old
House Number
4753
Street Name
North Shore
Street Type
Drive
Address
4753 North Shore Dr
Document Type
Misc
PIN
0711723320020
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DATE: July 23, 1993 <br /> PROJECT NO: 4140 92-2757 PAGE: 3 <br /> SAMPLE IDENTIFICATION: <br /> EPS thermal insulation molded to meet the requirements of ASTM C578, Type I and Type II classification, <br /> were submitted to our laboratory by Diversifoam Products, Rockford, Minnesota <br /> in August <br /> sheets each of 89 for ere <br /> Society of the Plastics Industry EPS Block Molders p Two 4' by 9' <br /> identified as follows: <br /> Type I: 2.73 inches thick, white in color <br /> Type 1I: 2.52 inches thick, white with green beads <br /> le thicknesses were designed to provide reference thermal resistance values of approximately 10 <br /> The sam p <br /> h-fe-'F/Btu. The tested R-values and densities were as follows: <br /> T_Xl� <br /> Aver Density lb/ft' Avera e R-Value h-fF-'F/Btu <br /> 1.01 10.2 <br /> 1 1.46 10.6 <br /> II <br /> OBSERVATIONS• ' <br /> The general condition of test samples was documented upon removal from the foundation each year: <br /> First <br /> Year: Scattered minor surface cracks and indentations were obser ed brushing). amount <br /> significant <br /> ficant <br /> impregnation in the surface was apparent (that which could nopbarent deterioration of the EPS;boards due <br /> distortion, shrinkage or swelling ha ma was <br /> haveevident. <br /> occurred There was no a p <br /> to any freeze-thaw cycling y <br /> Year: Scattered minor surface cracks and indentations were observed. A greater amount of soil <br /> Second y g No significant <br /> impregnation in the surface was apparent (that which could not be removed b brushing). g <br /> ion shrinkage or swelling was evident. There was no apparent deterioration of the EPS boards due <br /> distort , <br /> to any freeze-thaw cycling that may have occurred. <br /> Year: Apart from some slight damage during the removal, the two <br /> na ion in the surface s were intact. was sdl <br /> Third Yea psoil <br /> minor surface cracks and indentations were observed. Some significant distortion, shrinkage or swelling <br /> apparent (that which could not be removed by brushing). No sig <br /> was evident. There was no apparent deterioration of the EPS boards due to any freeze-thaw cycling that <br /> may have occurred. <br /> Refer to Appendix C for photographs of the samples. <br /> CORPORATION REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CL:E%T <br /> AS A MUTUAL PROTECTION TO CLIE»TS.THE PUBLIC AND OURSELVES All TWIN CITY TESTING <br /> A»0 AUTMCRIZATION FOR PUBLICATION OF STATEMENTS.CONCLUSIONS OR EXTRACTIONS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR PRIOR'N R'^Tvv�a?Pa0\r� <br />
The URL can be used to link to this page
Your browser does not support the video tag.